HomeMy WebLinkAboutEpoxy Flooring Various Buildings - Black Diamond WIDocusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 e ���� � COPY of Oshkosh CONTRACTOR AGREEMENT: INSTALLATION OF EPDXY FLOORING- VARIOUS BUILDINGS THIS AGREEMENT, made on the 15TH day of NOVEMBER, 2024, by and between the CITY OF OSHKOSH, party of the first part, hereinafter referred to as CITY, and BLACK DIAMOND WISCONSIN, P.O. BOX 7263, APPLETON, WI 54912, hereinafter referred to as the CONTRACTOR, WITNESSETH: That the City and the Contractor, for the consideration hereinafter named, enter into the following agreement. The Contractor's proposal is attached hereto and reflects the agreement of the parties except where it conflicts with this agreement, in which case this agreement shall prevail. ARTICLE I. COMPONENT PARTS OF THE CONTRACT This contract consists of the following component parts, all of which are as fully a part of this contract as if herein set out verbatim, or if not attached, as if hereto attached: A. This Instrument B. Proposal Solicitation C. Contractor's Proposal In the event that any provision in any of the above component parts of this contract conflicts with any provision in any other of the component parts, the provision in the component part first enumerated above shall govern over any other component part which follows it numerically except as may be otherwise specifically stated. ARTICLE II. PROTECT MANAGER A. Assignment of Project Manager. The Contractor shall assign the following individual to manage the project described in this contract: (ANDREW NICKELATTI, OWNER) B. Changes in Project Manager. The City shall have the right to approve or disapprove of any proposed change from the individual named above as Project Manager. The City shall be City Hall, 215 Church Avenue P.O. Box 1 130 Oshkosh, WI 54903-1130 http://www.ci.oshkosh.wi.us Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 provided with a resume or other information for any proposed substitute and shall be given the opportunity to interview that person prior to any proposed change. COPY ARTICLE III. CITY REPRESENTATIVE The City shall assign the following individual to manage the project described in this contract: (Mike Blank, Facilities Project Coordinator) ARTICLE IV. SCOPE OF WORK The Contractor shall provide the services described in the City's INVITATION FOR BID for the Project titled "INSTALLATION OF EPDXY FLOORING: VARIOUS BUILDINGS" dated October 11, 2024, and the contractor's bid form and materials attached as Exhibit A. If anything in the Bid Form conflicts with the Bid Specifications, the provisions in the Bid Specifications shall govern. The Contractor may provide additional products and/or services if such products/services are requested in writing by the Authorized Representative of the City. ARTICLE V. CITY RESPONSIBLTTIES The City shall furnish, at the Contractor's request, such information as is needed by the Contractor to aid in the progress of the project, providing it is reasonably obtainable from City records. To prevent any unreasonable delay in the Contractor's work the City will examine all reports and other documents and will make any authorizations necessary to proceed with work within a reasonable time period. ARTICLE VI. TIME OF COMPLETION The Contractor shall complete the project no later than April 1, 2025. Any changes to the completion date must be agreed upon by both parties in writing. ARTICLE VII. PAYMENT A. The Contract Sum. The City shall pay to the Contractor $63,387.50, adjusted by any changes hereafter mutually agreed upon in writing by the parties hereto. B. Fee schedules shall be firm for the duration of this Agreement. i. Method of Payment. The Contractor shall submit itemized monthly statements for services. The City shall pay the Contractor within 30 calendar days after receipt of such statement. If any statement amount is disputed, the City may withhold payment of such amount and shall provide to Contractor a statement as to the reason(s) for withholding payment. ii. Additional Costs. Costs for additional services shall be negotiated and set forth in a written amendment to this agreement executed by both parties prior to proceeding with the work covered under the subject amendment. Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 ARTICLE VIII. STANDARD PROVISIONS COPY The CONTRACTOR agrees in all hiring or employment made possible by or 1 esulting from th. s agreement, there will not be any discrimination against any employee or applicant for employment because of race, color, religion, sex, sexual orientation, gender identity, or national origin. ARTICLE IX. CONTRACTOR TO HOLD CITY HARMLESS The Contractor covenants and agrees to protect and hold the City of Oshkosh harmless against all actions, claims and demands of any kind or character whatsoever which may in any way be caused by or result from the intentional or negligent acts of the Contractor, his agents or assigns, his employees or his subcontractors related however remotely to the performance of this Contract or be caused or result from any violation of any law or administrative regulation, and shall indemnify or refund to the City all sums including court costs, attorney fees and punitive damages which the City may be obliged or adjudged to pay on any such claims or demands within thirty (30) days of the date of the City's written demand for indemr fication or refund. ARTICLE X. INSURANCE The Contractor shall provide insurance for this project that includes the City of Oshkosh as an additional insured. The contractor's certificate of insurance for this project is attached as Exhibit B. ARTICLE XI. TERMINATION C. For Cause. If the Contractor shall fail to fulfill in timely and proper manner any of the obligations under this Agreement, the City shall have the right to terminate this Agreement by written notice to the Contractor. In this event, the Contractor shall be entitled to compensation for any satisfactory, usable work completed. D. For Convenience. The City may terminate this contract at any time by giving written notice to the Contractor no later than 10 calendar days before the termination date. If the City terminates under this paragraph, then the Contractor shall be entitled to compensation for any satisfactory work performed to the date of termination. This document and any specified attachments contain all terms and conditions of the Agreement and any alteration thereto shall be invalid unless made in writing, signed by both parties and incorporated as an amendment to this Agreement. Signatures. By placing their signatures below, each individual affirms that the entity they represent is authorized to enter into this Agreement, and further affirm that they are authorized by the entity they are representing to bind their respective parties to the terms and conditions of this Agreement. Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 BLACK DIAMOND, WISCONSIN DocuSld bCOPY By: E /�y Andrew Nickelatti C= OF OSHKOSH Signed by: E� By: 010E644DDEB0484 . City Manager Signed by: And: City Clerk APPROVED: I hereby certify that the necessary provisions have been made to pay the liability which E:,,,'�- gnd by: will accrue under this contract. , pa.\ Signed by: rl�..,3237442D4E5... E � �� �"`-�' City AttorneyCAERMAnAnr City Comptroller Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 CITY OF OSHKOSH INVITATION FOR BID COPY INSTALLATION OF EPDXY FLOOR COATING: VARIOUS BUILDI G S BID PROPOSAL FORM Page 1 of 2 From: �uG� i �+W` �a ti (bidder's company name) BID SUBMITTAL DEADLINE: BY 11:00 A.M., TUESDAY, NOVEMBER 5, 2024 Date: lk Iq 1 �01. Addenda: Receipt of Addenda numbered of are hereby understood, acknowledged and included in bidder's bid proposal form. If no addenda were issued for this project please write "N/A" above. In compliance with the advertising for Bids and having carefully examined the drawings and/OR specification for the Work and the Site of the proposed work and having determined all of the conditions of the work, the rules, regulations, laws, codes, ordinances, and other governing circumstances relating to this project, the undersigned proposes to furnish all Labor, Materials and Equipment necessary to complete the construction indicated on the drawings and described in the project manual to include all described work completed to the Owners' satisfaction. By Submission of this Bid, each Bidder certifies, and in the case of a joint Bid, each party thereto certifies as to its own organization, that this Bid has been arrived at independently without consultation, communication, or agreement as to a matter relating to this Bid and with any other Bidder or with any competitor. We, the undersigned, propose to furnish all labor and materials per the project specifications or noted deviations for the following amount(s): TOTAL BASE BID TO INSTALL EPDXY FLOOR COATING AT VARIOUS BUILDINGS PER BID SPECIFICATIONS: 1411'R(41- -�V5RI`k I' at, 6�ktl t4Ak cn (Slfs (Base Bid Price — in 21 Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 CITY OF OSHKOSH INVITATION FOR BID COPY INSTALLATION OF EPDXY FLOOR COATING: VARIOUS BUILD BID PROPOSAL FORM Page 2 of 2 SIGNATURES Date: Name of Company: &ge-K- Submittedby: (name/title) _Ufs.W N;CWA'I'OWh#,(- Email: QINI(tw OCkOici+►^a� jvs.t°v'— Address of Company: �b �d`� �] a �t �Q � 1�1i 5111) Phone: 7 ko- Il - 72 1� Company Re resent that wi]R be named Project Manager for this project, if awarded the bid: _ Wfe w M&Kt�iftl / ,/_ ! Signature Title 010,16r Company Re e+sentati�aa"—Email:veauthorized to sign contracts electronically via 1DocuSign: Name: he GW �n T w (uc� i aW�oyial Wi •Cain' That I have examined and carefully prepared this Proposal from the Plans and Specifications and have checked the same in detail before submitting this Proposal; that I have full authority to make such statements and submit this Proposal in (its) (their) behalf, and that said statements are true and correct. Signature Title Warranty Details: �t, Jk%+1A owvAc.r- M Data Sheets on products to be used during install are attached. 22 Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 w.m... COPY Black Diamond Wi warranty covers Workmanship (labor induced issues) and Product Defect (curing and adhesion of coatings to one another), Items not covered under warranty are moisture, rust filled saw cuts (cracking), deteriorating concrete, outdoor exterior applications,, non -concrete coated surfaces, or in other words items that are not controllable. Residentiak LiTetime 15 Year (NorNTransferabfe) Commercial: 5 years (Non: Transferable) Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 RAICKVIAMONIJ CONCRETE COATIMO EXPERTS Black Diamond Wi PO Box 7263 Appleton Wi 54912 andrew@blackdiamondwi,com (920) 279-7216 Prepared For: City Of Oshkosh 215 Church Ave Oshkosh, Wisconsin 54901 (920) 236-5101 hmagrady@oshkoshwi,gov Description ESTIMATE COPY Estimate # 729-1 Date Mon Nov 04 2024 Total 63387.50 Service Location: City Of Oshkosh 215 Church Ave Oshkosh, Wisconsin 54901 (920) 236-5101 Price Amount Page 1 Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 Police Department Storage 640 W 3rd Ave Oshkosh, Wi Large Bay Area )- Install new epoxy flooring, with 50-mil flake with urethan topcoat. n City will choose flake color. > Bidder will shot -blast or diamond grind floors to create suitable bonding surface. >- Bidder will patch all cracks, joints, divots, etc. prior to first coat. > Bidder will install MB moisture block primer at 16- mils. >- Once cured, bidder will apply second coat of UVR with full flake broadcast. s- Bidder will then vacuum -clean surface and apply UVR grout coat at 12-14 mils. a Floor will then be sealed with 3-5 mils of urethane. > Bidder to provide data sheet on all products to be used with bid submittal. - Detective Mechanic Bay, NE Storage & NW Storage > Install new epoxy flooring, with 60-mil solid color with urethan topcoat. City will choose solid color. m Bidder will shot -blast or diamond grind floors to create suitable bonding surface. >- Bidder will patch all cracks, joints, divots, etc. prior to first coat. > Bidder will install MB moisture block primer at 16- mils. 11 n Once cured, bidder will apply second coat of UVR with full flake broadcast, >- Bidder will then vacuum -clean surface and apply UVR grout coat at 12-14 mils. > Floor will then be sealed with 3-5 mils of urethane. > Bidder to provide data sheet on all products to be used with bid submittal. $31730.5 $31730.50 I= Page 2of4 Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 1 FIRE DEPARTMENT STATION 15 $26352 $26352,00 101 COURT STREET Oshksh, Wi • Install new epoxy flooring with 60-mil solid color with COPYurethan topcoat. • City will choose solid color, • Bidder will first shot -blast or diamond grind floor the three areas of recent trench drain replacements to create suitable bonding surface, • Bidder will then install Sika 24NA at 3116" broadcast with sand to rejection. • Bidder will then remove excess sand, seal floor with Sika 510 in a color to best match surrounding. • Once these areas are cured and complete, bidder will then mechanically abrade the entire apparatus bay area. • Bidder will patch all cracks, joints, divots, etc. • Bidder will apply basecoat of epoxy and see 100% with wedron 480 sand. • Biller will remove excess sand then seal with UVR topcoat at 16 mils. • Bidder will add in safety lines. • Bidder to provide data sheet on all products to be used with bid submittal, OSHKOSH SENIORS CENTER SOUTH $5305 $5305,00 200 N. CAMPBELL ROAD Oshkosh, WI • Install new epoxy flooring with 50-mil flake with urethan topcoat, • Bidder will remove carpet In Classroom C and remove VCT the in Art Room, • Bidder will provide d'umpster for all debris. • Bidder will shot -blast or diamond grind floors to create suitable bonding surface. • Bidder will patch all cracks, joints, divots, etc, prior to first coat, •City will choose flake color, • Bidder will install MB moisture block primer at 16-mils. • Once cured, bidder will apply second coat of UVR with full flake broadcast. • Bidder will then vacuum -clean surface and apply UVR grout coat at 12-14 mils. • Floor will then be sealed with 3-5 mils of urethane, • Bidder to provide data sheet on all products to be used with bid submittal. Sub total $63387.50 Total $63387.50 Page 3 of 4 Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 Terms: Quotes are good for 60 days, after that they are subject to change. Acceptance of bid requires 50% non-refundable deposit to schedule the project. Checks m a t�J "Black Diamond Wt." Remainder is due upon completeion of project. j All work listed above will be installed in a workmanlike manner according to standard practices. Any alteration or deviation from the above specifications, including extra costs, will executed only upon written orders, and will become and extra charge over and above the estimate. Black Diamond WI is not responsible for damages to walls, baseboards or any other finishes, moisture reacted issues, bugs and other contaminents, dust, movement of epoxy, and or colors. We are also not liable for any damages to installed finish caused by humans, pets, and or weather. Each floor is one of a kind and unique and will not replicate any photos of any floors. All agreements contingent upon strikes, accidents, or delays, beyond our control. Credit Card payment will be charged an additional 3.0% for processing fees associated. Notes: Thank You For Choosing Black Diamond Concrete Coatings! Like us on Facebook at www.facebook.com/BlackDiamondW! and Follow us on Instagram at BlackMamondWl Page 4 of 4 Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 i3LACKVMMVNi7 SAFETY D TA S EFT COR eXLT2 LO.fT/MG fXIL.LTY I * Issue Date Date 1-October-2021 COJLVeron 2.1 Product identifier Product Name HD Topcoat Stow Cure - Part A (Black Diamond) Recommended use of the chemical and restrictions on use Recommended Use Concrete Coating. Uses advised against No Data Details of the sunolier of the safetv data sheet Distributor Address Black Diamond Concrete Coatings Omro, WI 54963 920-279-7216 Emergency teleohone number Company Phone Number 920-279-7216 24 Hour Emergency Phone Number 800-535-5053 (United States & Canada), International Call: 1-352-323-3500 :6. .F - 7vg t L?. -l' 5 A/-- i / y��/.(a{j ��wf'MY !■c `� =__ lL ��x-- E_.w.:Yi` TFi:S-�\�,Y'A+!)F.,.�_�,.. 1 Classification OSHA Regulatory Status This chemical is considered hazardous by the 2012 OSHA Hazard Communication Standard (29 CFR 1910.1200) te toxici - Inhalation a rs at 4 cific tar et or an toxici sin lee osure ate 3 rp1ratton toxtcit ate 1 mmabie Liquids Category 3 Label elements Emergency Overview angers Hazard statements Toxic to Aquatic Life with Long Lasting Effects Causes Serious Eye Irritation ay Cause Respiratory Irritation ay Cause Drowsiness or Dizziness ay be Harmful if Swallowed May be Harmful If Swallowed and Enters Airways auses Skin Irritation < < >< Appearance Transparent Liquid Physical state liquid Odor Soiven Page 1 18 Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 HD TopCoat Slow Cure - Part A Precautionary Statements - Prevention Obtain special instructions before use Do not handle until all safety precautions have been read and understood Keep away from heat/sparks/open flames/hot surfaces. - No smoking Keep container tightty closed Ground/bond container and receiving equipment Use explosion -proof electrical/ ventilating / lighting/ equipment Use only non -sparking tools Take action to prevent static discharges Avoid breathing dust/fume/gas/mist/vapors/spray Wash face, hands, and any exposed skin thoroughly after handling Use only outdoors or in a well -ventilated area Avoid release to the environment Wear protective gloves/protective clothing/eye protection/face protection bate 1-October-2021 Precautionary Statements - Response iF exposed or concerned: Get medical advice/attention iF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/ shower If skin irritation occurs: Get medical advice or attention. IF IN EYES: Rinse cautiously with water for several minutes. Remove contacts, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice/attention IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER/doctor if you feel unwell. IF SWALLOWED: Immediately call a POISON CONTROL CENTER/doctor Do NOT Induce vomiting. Take off contaminated clothing and wash before reuse In case of fire use, "alcohol resistant" foam, dry chemical, halon, or carbon dioxide to extinguish. Collect spillage Precautionary Statements - Storage Store in well -ventilated place. Keep Cool. Keep container tightly closed. Store locked up. Precautionary Statements = Dlsposal Dispose of contents/container in accordance with local/regional/national regulations. Hazards not otherwise classified IHNOM Repeated exposure may cause skin dryness or UBCV(N Other Information f� Y `QiV1?(;lt(�;FdRIVt1tN_ rltt,RED1E� Substance Chemical Name CAS No. Weight-1/6 Trade Secret -Poi of P Leta 10 - 30 ' 1,1'-Methylenebis[(3-methylcyelohexyl-4)-2-amino- butanedloic acid], tetraethyl ester 136210-32-7 60 -100 Ethyl 3-etho roanoate 763-96-9 3-7 *The exact percentage (concentration) of composition has been witnneia as a trace souet. ,a L. x.F a �,� .f., ..,,. '•sue '- 4 t .-ufx1�,,�AiD-slYtVS-!A, ..r`_' �_..._...Y.. f nr �. M= Description of first aid measures General advice Move out of the dangerous area. Consult a physician. Provide this Safety Data Sheet to the doctor In attendance. Eye contact IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, If present and easy to do. Continue rinsing. If eye Irritation persists: Get medical advice/attention. Page 2 / 8 Docusign Envelope ID: D6082DCl-252A-402D-B8EC-OECD6C4BC9A3 HD TopCoat Slow Cure - Part A Date 1-October-2021 Skin contact IF ON SKIN (or hair): Removell-ake off immediately all containCtedskin with water/shower. Wash off immediately with soap and pleopsk`Yrsdi tion persists, call a physician. Inhalation IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. If breathing is irregular or stopped, administer artificial respiration. If symptoms persist, call a physician. Ingestion IF SWALLOWED: Immediately call a POISON CENTER or doctor/physician. Do NOT induce vomiting. Never give anything by mouth to an. unconscious person. Most important symptoms and effects both acute and delayed Symptoms Eye, Skin, and Respiratory Irritation. May cause allergic skin reaction. Indication of any Immediate medical attention and special treatment needed Note to physicians Treat symptomatically. For additional information, see Safety Data Sheet. Suitable extinguishing media Dry Chemical, Alcohol Resistant Foam, Halon or Carbon Dioxide. Unsuitable extinguishing media CAUTION: Use of water spray when fighting fire may be inefficient. Specific hazards arising from the chemical In a fire or if heated a pressure increase may occur and the container may burst. Hazardous combustion productsCarbon dioxide (CO2). Carbon monoxide. Explosion data Sensitivity to Mechanical Impact Not available. Sensitivity to Static Discharge May be Ignited by friction, heat, sparks, or flames. Protective equipment and precautions for firefighters Wear self-contafned breathing apparatus and protective suit. Personal precautions protective equipment and emergency procedures Personal precautions Use personal protective equipment as required. P261 - Avoid breathing dUst/fume/gas/mist/vapors/spray. Ensure adoquate ventilation, especially in confined areas. Remove all sources of Ignition. Evacuate personnel to safe areas. Beware of vapors accumulating to form explosive concentrations. Vapors can accumulate in tow areas. Eny4ranmerita( precautions Environmental precautions Prevent further leakage or spillage if safe to do so. Do not allow product to enter any drains or waterways. Methods and material for containment and cleaning up Methods for containment Prevent further leakage or spillage if safe to do so. Dike to collect large liquid spills. Methods for cleaning up Use a non-combustible material like vermiculite or sand to soak up the product and place into a container for later disposal. Use clean non -sparking tools to collect absorbed material. Page 3 1 8 Docusign Envelope ID: D6082DCl-252A-402D-B8EC-OECD6C4BC9A3 HD TopCoat Slow Cure - Part A Dispose according to local regulations. Precautions for safe bandlin Date 1-October-2021 Advice on safe handling Do not handle until all safety precautions have been read and understood. Avoid contact with skin and eyes, Avoid breathing dust/fume/gas/mist/vapomispray. Keep away from heat, hot surfaces, sparks, open flames, and other ignition sources. No smoking. Ground and bond container and receiving equipment. Take measures to prevent the buildup of electrostatic charge. Use non -sparking tools. Wash hands and skin thoroughly after handling. Use only outdoors or in a welt -ventilated area. Wear protective gtoveslprotective clothingleye protection/face protection. Conditions for safe storage Including any Incompatibilities Storage Conditions Keep container tightly closed in a dry and well -ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Incompatible materials Keep away from strong oxidizing agents, strong alkalis, and strong acids. REF41.IRA.t�'pSt�IV1�.=. Control parameters Exposure Guidelines This product, as supplied, does not contain any hazardous materials with occupational exposure limits established by the region -specific regulatory bodies. Appropriate engineering controls Engineering Controls General/Local Ventilation Recommended. Individual protection measures such as personal protective equipment Eye/face protection Wear safety glasses with side shields (or goggles). Skin and body protection Wear impervious protective clothing, including boots, gloves, lab coat, apron, or coveralls, as appropriate, to prevent skin contact. Wear chemical resistant gloves at minimum. Wash skin Immediately upon contact. Wash hands at mealtime and end of shift. Respiratory protection Use respiratory protection unless adequate local exhaust ventilation is provided, or exposure assessment demonstrates that exposures are within recommended exposure guidelines. Where concentrations are above recommended limits or are unknown, appropriate respiratory protection should be wom. Follow OSHA respirator regulations (29 CFR 1910.134) and use NIOSH/MSHA approved respirators. General Hygiene Considerations Handle in accordance with good Industrial hygiene and safety practice. Wash hands before and after breaks and at the end of the workday. ..fir ..�... .. Information on basic physical and chemical properties Physical state liquid Appearance Transparent Liquid Odor Solvent Color Transparent Liquid - May have slight Odor threshold No data available color due to perfonnance additives. Pro Values Rem3ft—m; Meth-od pH Not Relevant Page 4 / 8 Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 HD TopCoat Slow Cure - Part A Melting point Ifreezing point Not Available Boiling point / boiling range 194°F (90°C) Flash point > 42 °C 109 °F Evaporation rate Not Available Flammability (solid, gas) Not Relevant Flammability Limit in Air Upper flammability limit.' Not Available Lower flammability limit: Not available Vapor pressure Not Available Vapor density Not Available Relative density 1.039 @ 70 Degrees F Water solubility Insoluble in water Solubility in other solvents Not Available Partition coefficient Not Available Autoignition temperature Not Available Decomposition temperature Not Available Kinematic viscosity Not Available Dynamic viscosity Not Available Explosive properties Not Available Oxidizing properties Not Availabte Other Information Softening point Not Relevant Molecular weight Not Available VOC Content (%) < 250 g/L (Mixed A&B) Density Not Available Bulk density Not Available Reactivi Not Available Chemical stability Stable. Possibility of Hazardous Reactions Hazardous polymerization does not occur. Conditions to avoid Heat, flames, and sparks. Incompatible materials Keep away from strong oxidizing agents, strong alkalis, and strong acids. CC (dosed cup) Transparent Liquid Transparent Liquid Hazardous Decomposition Products Hazardous decomposition products formed under fire conditions, carbon oxides. information on likely routes of exposure Product Information Inhalation Direct contact and vapor inhalation. Eye contact Direct contact. Skin contact Direct contact. Page 5 / 8 Date 1-October-2021 Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 HD TopCoat Slow Cure - Part A Ingestion Information on tUXicolocticat effects Symptoms Date 1-October-2021 Direct contact. May cause drowsiness or dizziness if inhaled. May cause respiratory Irritation. Causes serious eye Irritation. Causes skin Irritation. Delayed and Immediate effects as well as chronic effects from short and Ion4-term exposure Skin corroslon/irritation Serious eye damagefeye irritation irritation Sensitization Germ cell mutagenicity Carcinogenicity Reproductive toxicity STOT - single exposure STOT - repeated exposure Aspiration inazard Causes severe bums. Irritating to skin. Irritating to eyes. Risk of serious damage to eyes. Irritating to eyes, respiratory system, and skin. No data available. No data available. No data available. Not Available. Not Available. Not Available. Not Available. Numerical measures of toxicity - Product Inforrnatio Material is expected to be harmful to aquatic organisms. May cause long-term adverse effects In the aquatic environment. Ecotoxicity Persistence and degradability No data available. Bloaccumulation No data available. Other adverse effects No data available. Waste treatment methods Disposal of wastes Under RCRA 40 CFR 261 this material is a hazardous waste. Dispose of in accordance with all federal,, state, and local regulations, if uncertain of local requirements, contact the proper environmental authorities for information on waste disposal in your area. Contact a licensed professional waste disposal service to dispose of this material. Contaminated packagtng Dispose of irti accordance vrittr federat, state, a"d Local regutations. WHEM- DOT Not Regulated IATA UN1263, PAINT RELATED MATERIAL, 3, II IMDG UN1263, PAINT ERELATED Tg �/MATERIAL, 7�3, II S"1'I��f �1.1Y1/"�. <rA' Page 6 1 8 Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 HD TopCoat Slow Cure - Part A Date 1-October-2021 1tctemat4onal Iseyetr,tos9es COPY TSCA Does not comply DSLMDSL Does not comply EiNECS/ELINCS Does not comply ENCS Does not comply IECSC Does not comply KECL Does not comply PICCS Does not comply AICS Does not comply Legend; TSCA- united States Toxic Substances Control Act Section 8(b) inventory DSL[NDSL - Canadian Domestic Substances List/Non-Domestic Substances List EiNECSIELINCS - European Inventory of Existing Chemical Substances/European List of Notified Chemical Substances ENCS - Japan Existing and New Chemical Substances IECSC - China Inventory of Existing Chemical Substances KECL - Korean Existing and Evaluated Chemical Substances PICCS - Philippines Inventory of Chemicals and Chemical Substances AICS - Australian Inventory of Chemical Substances US Federal Reputations_ SARA 313 Section 313 of Title it[ of the Superfund Amendments and Reauthorization Act of 1986 (SARA), This product does not contain any chemicals which are subject to the reporting requirements of the Act and Title 40 of the Code of Federal Regulations, Part 372 SARA 311/312 Hazard Categories Acute health hazard Yes Chronic Health Hazard Yes Fire hazard Yes Sudden release of pressure hazard Yes Reactive Hazard No CWA (Clean Water Act) This product contains the following substances which are regulated pollutants pursuant to the Clean Water Act (40 CFR 122-21 and 40 CFR 122.42) CERCLA This material, as supplied, contains one or more substances regulated as a hazardous substance under the Comprehensive Environmental Response Compensation and Liability Act (CERCLA) (40 CFR 302) US State Recfulations California Proposition 65 This product contains chemicals known to the state of California to cause birth defects or other reproductive harm U.S. State Right -to -Know Regulations U.S. EPA Label Information t.t>:10i1fL1�#-1f�JG Ftt7i {X,R'IE�i1flk:AE3 _l": . 4t, ,.su NFPA HMIS Issue Date Date Revision Note Disclaimer Health hazards 2 Flammability 2 Health hazards 2 Flammability 2 1-October-2021 Page 7 Instability 0 Physical hazards 0 Physical and Chemical Properties - Personal protection X Docusign Envelope ID: D6082DCl-252A-402D-B8EC-OECD6C4BC9A3 HD TopCoat Slow Cure - Part A Date 1-October-2021 The Information provided In this Safety data Sheet is correct to the best of our knowledge, infox mation, and belief a the date of Its publication. The Information given Is designed only as a guidance for safe handling, Cr()p ofge, transportation, disposal, and release and is not to be considered a warranty or quality speciflcatio o re ates only to the specific material designated and may not be valid for such material used In combinatio with any other mate rials or In any process, unless specified In the text. End of Safety Data Sheet Page 8 1 8 Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 �p$L,ACKWAMVNi7 SAFEW DAT ` c OM-11l co 1— <X/l.112 Issue Date Date 1-October-2021 Ico Product Identifier Product Name HD TopCoat Slow Cure - Part B (Black Diamond) Recommended use of the ahemleal and restrictions on use Recommended Use Concrete Coating. Uses advised against No Data Details of the supplier of the safety data sheet Distributor Address Black Diamond Concrete Coatings Omro, Wl 54963 920-279-7216 Emeraegcv telephone number Company Phone Number 920-279-7216 24 Hour Emergency Phone Number 800-535-5053 (United States & Canada), International Call: 1-352-323-3500 Classification OSHA Regulatory Status This chemical is considered hazardous by the 2012 OSHA Hazard Communication Standard (29 CFR 19101200) 2.1 ute toxic! - Oral atego 5 ute toxicit - Inhalation (Vapors) at o 4 n corrasionfirritation [erious at lateanru2 2 e e dams ele a irritation ate 2A ecrf!c tar et organ toxic!ty (sin leexposure) ate 3 s !ration toxic!ty lammable liquids Category 2 Hazardous to the Aquatic Environment - Long Term Chronic Hazard Category 2 Label elements angerl Hazard statements Toxic to Aquatic Life with Long Lasting Effects Causes Serious Eye Irritation May Cause Respiratory Irritation May Cause Drowsiness or Dizziness May be Harmful if Swallowed May be Harmful if Swallowed and Enters Airways Causes Skin Irritation Emeraencv overview Page 1 1 8 Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 HD TopCoat Slow Cure - Part B Date 1-October-2021 state Precautionary Statements - Prevention Obtain special instructions before use Do not handle until all safety precautions have been read and understood Keep away from heat/sparks/open flamesthot surfaces. - No smoking Keep container tightly closed Groundibond container and receiving equipment Use explosion -proof electrical/ ventilating / fighting/ equipment Use only non -sparking tools Take action to prevent static discharges Avoid breathing dustftne/gas/mist/vapors/spray Wash face, hands and any exposed skin thoroughly after handling Use only outdoors or in a well -ventilated area Avoid release to the environment Wear protective gloves/protective ctothtng/eye protection/face protection Precautionary Statements - Response IF exposed or concerned: Get medical advice/attention IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/ shower If skin irritation occurs: Get medical advice or attention. IF IN EYES: Rinse cautiously with water for several minutes. Remove contacts, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advicelattention iF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CEN' TEPJdoctor'li you feel unwell. IF SWALLOWED: Immediately call a POISON CONTROL CENTER/doctor Do NOT induce vomiting. Take off contaminated nothing and wash before reuse In case of fire use, "alcohol resistant" foam, dry chemical, halon or carbon dioxide to extinguish. Collect spillage Precautionary Statements -Storage Store in well -ventilated place. Keep Cool. Keep container tightly closed. Store locked up. Precautionary Statements - Disposal Dispose of contents/container In accordance with local/regional/national regulations. Hazards not otherwise classified f HNOC) Repeated exposure may cause skin dryness or cracking Other Information �,, _ �i, ri.C?IVi�'fIU1�/fNFRMAT�QN.t�I�Nl4�N _ {.� J Substance Chemical Name CAS No. I Weight-0/6 Trade Secret Pml hexameth ne Oftocy anete 28162-t31-2 40 - 70 " Ethyl 3-etho ro anoate 763-96-9 15 - 40 *The exact percentage (concentration) of composition has been withheld as a trade secret. JR it Descriation of first aid measures General advice Move out of the dangerous area. Consult a physician. Provide this Safety Data Sheet to the doctor In attendance. Eye contact IF IN EYES: Rinse cautiously with water for several minutes. Remove contact tenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice/attention. Page 2 / 8 Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 HD Topcoat Stow Cure - Part B Date 1-October-2021 Skin contact IF ON SKIN (or hair): Remove/Take off immediately all contarri to I ` s skin with water/shower. Wash off immediately with soap and plen ..�.sklr�irri ation persists, call a physician. Inhalation iF INHALED: Remove victim to fresh air and keep at rest In a position comfortable for breathing. if breathing is irregular or stopped, administer artificial respiration. If symptoms persist, call a physician. ingestion IF SWALLOWED: Immediately call a POISON CENTER or doctor/physician. Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Most important symptoms and effects, both acute and delayed Symptoms Eye, Skin, and Respiratory Irritation. May cause allergic skin reaction. indication of any immediate medical attention and special treatment needed Note to physicians Treat symptomatically. For additional Information, see Safety Data Sheet. 'dx, 7ri_ E1'r e.7 .aF- . .., _.J 4.a .:.-ti..'-'� .S±N���tFltL: iJ�2�"T.♦..il@M7�JYli.caV��i_Y�;4�� .,","5 [,�� .r .....i x r�r ti,. '"Y -i Suitable extinguishing media Dry Chemical, Alcohol Resistant Foam, Halon or Carbon Dioxide. Unsuitable extinguishing media CAUTION: Use of water spray when fighting fire -nay be inefficient. Specific hazards arising from the chemical In a fire or if heated a pressure increase may occur and the container may burst. Hazardous combustion productsCarbon dioxide (CO2). Carbon monoxide. Explosion data Sensitivity to Mechanical Impact Not available. Sensitivity to Static Discharge Maybe ignited by friction, heat, sparks, or flames. Protective equipment and precautions for firefighters Wear self-contained breathing apparatus and protective suit. Personal precautions, protective equipment, and emergency procedures Personal precautions Use personal protective equipment as required. P261 - Avoid breathing dust/fumelgas/mist/vapors/spray. Ensure adequate ventilation, especially in confined areas. Remove all sources of ignition. Evacuate personnel to safe areas. Beware of vapors accumulating to form explosive concentrations. Vapors can accumulate in low areas. Environmental precautions Environmental precautions Prevent further leakage or spillage If safe to do so. Do not allow product to enter any drains or waterways. Methods and matgrlal for containment and cleaning up Methods for containment Prevent further leakage or spillage if safe to do so. Dike to collect large liquid spills. Methods for cleaning up Use a non-combustible material like vermiculite or sand to soak up the product and place Into a container for later disposal. Use clean non -sparking tools to collect absorbed material. Page 3 / 8 Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 HD Topcoat Slow Cure - Part B Date 1-October-2021 Dispose according to tocat regulations. Precautions for safe handling Advice on safe handling Do not handle until all safety precautions have been read and understood. Avoid contact with skin and eyes. Avoid breathing dust/fumelgas/mist/vapors/spray. Keep away from heat, hot surfaces, sparks, open flames, and other Ignition sources. No smoking. Ground and bond container and receiving equipment Take measures to prevent the buildup of electrostatic charge. Use non -sparking tools. Wash hands and skin thoroughly after handling. Use only outdoors or In a well -ventilated area. Wear protective gloveslprotective r7othing/eye protection/face protection. Conditions for safe storage including any incompatibilities Storage Conditions Keep contalner tightly closed in a dry and well -ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage. incompatible materials Keep laway from strong oxidizing agents, strong alkalis, and strong acids. . 3 ` ;'. it �:m �`l. ? SY',L+fili:'T �iliw�.VR.1 ^!:..tT: • .. i..M �. . - K� a� _n * - Control parameters Exposure Guidelines This product, as supplied, does not contain any hazardous materials with occupational exposure limits established by the regiorvspeciflcregulatory bodies. Appropriate englneering controls Engineering Controls General/Local Ventilation Recommended. Individual protection measures such as personal protective equipment Eyelface protection Wear safety glasses with side shields (or goggles). Skin and body protection Wear impervious protective clothing, including boots, gloves, lab coat, apron, or coveralls, as appropriate, to prevent skin contact. Wear chemical resistant gloves at minimum. Wash skin immediately upon contact. Wash hands at mealtime and end of shift Respiratory protection Use respiratory protection unless adequate local exhaust ventilation is provided, or exposure assessment demonstrates that exposures are within recommended exposure guidelines. Where concentrations are above recommended limits or are unknown, appropriate •respiratory protection -should be worn. Follow OSHA respirator regulations (29 OFR 1910.134) and use NIOSH/MSHA approved respirators. General Hygiene Considerations Handle in accordance with good industrial hygiene and safety practice. Wash hands before and after breaks and at the end of the workday. RN^ ! F HY> i,G/t►L t�-5 M CAN P. Information on basic physical and chemical properties Physical state liquid Appearance Transparent Liquid Odor Solvent Color Transparent Liquid - May have slight Odor threshold No data available color due to performance additives. Proven Values Remarks • Method PH Not Relevant Page 4 18 Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 HD TopCoat Slow Cure - Part B Melting point t fmazing point Not Avaitable Bolling point 1 boiling range 165-172°C Flash point > 42 °C 109 °F CC (dosed cup) Evaporation rate Not Available Flammability (solid, gas) Not Relevant Flammability Limit in Air Upper flammability limit: Not Available Transparent Liquid Lower flammability ilmlt: Not Available Transparent Liquid Vapor pressure Not Available Transparent Liquid Vapor density Not Available Transparent Liquid Relative density 1.077 @ 70 Degrees F Water solubility Insoluble In water Solubility in other solvents Not Available Partition coefficient Not Available Autolgnition temperature 377 °C (ASTM E659) Decomposition temperature Not Available Transparent Liquid Kinematic viscosity Not Available Dynamic viscosity Not Available Explosive properties Not Available Oxidizing properties Not Available Other infonnation Softening point Not Relevant Molecular weight Not Available VOC Content (%) < 250 g/L (Mixed A&B) Density Not Available Bulk density Not Available Date 1-October-2021 YriJ-N 'i ����_.:._r...i"..� ....-i t,...uCs).. IF � L, �✓/'}�������-A�_. t. i-ar � — ..: ','�-L3._ - �.,.'� Reactivity Not Available Chemical stability. Stable. Possibility of Hazardous Reactions No data avaltabie. Conditions to avoid Heat, flames and sparks. Incompatible materials Keep away from strong oxidizing agents, strong alkalis, and strong acids. Hazardous Decomposition Products Hazardous decomposition products formed under fire conditions, carbon oxides. 3 i "-Y r �. 5i ,q� - ' Ir .:T'p`)C[LO.A1' .,:I�dt11A'f'(,m m s.{. -, ',+'., T.. .. ft i .. .... '� ` .ate-,.. �_--5 :....•. ..: .. .r .. s.., c Information on likely routes of exposure Product Information Inhalation Direct contact and vapor inhalation. Eye contact Direct contact. Skin contact Direct contact, Page 5 18 Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 HD TopCoat Slow Cure - Part B ingestion Direct contact. Date 1-October-2021 I� hemical Name Oral LD50 Dermal LD50 otyhexamethylene Wsocyanate - - = 1850.0 mgtm' t #tat )1 h 28182-81-2 Information on toxicological effects Symptoms May cause drowsiness or dizziness if inhaled. May cause respiratory irritation. Causes serious eye irritation. Causes skin irritation. Delayed and immediate effects as well as chronic effects from short and long-term exposure Skin corrosionlirritation Serious eye damageteye irritation Irritation Sensitization Germ cell mutagenicity Carcinogenicity Reproductive toxicity STOT - single exposure STOT - repeated exposure Aspiratlon hazard Irritating to skin. Irritating to eyes. Risk of serious damage to eyes. IrTtaV% to eyes, Tesplratory sys%m' acid skin. May cause sensitization by inhalation. No data available. This product does not contain any carcinogens or potential IARC or NTP. Not Available. Not Available. Not Available. Not Available. Numerical measures of toxicity - Product Information Ecotoxlclty Persistence and degradability No data avaiiable. Bioaccumulation No data available. carcinogens as listed by OSHA, Other adverse effects No data available. Waste treatment methods Disposal of wastes Under RCRA 40 CFR 261 this material is a hazardous waste. Dispose of in accordance with all federal, state, and local regulations. If uncertain of locat requirements, contact the proper environmental authorities for information on waste disposal in your area. Contact a licensed professional waste disposal service to dispose of this material. Contaminated packaging Dispose of in accordance with federal, state, and local regulallon-s. n�IN�,x: .33 i DOT Not Regulated iATA UN1263, PAINT RELATED MATERIAL, 3, II IMDG UN1263, PAINT RELATED MATERIAL, 3, II Page 6 1 8 Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 HD TopCoat Slow Cure - Part 8 intemationai inventories TSCA Does not comply DSUNDSL Does not comply .EINECS/F,LINCS Does not comply ENCS Does not comply IECSC Does not comply KECL Does not comply PICCS Does not comply AiCS Does not comply Date 1-October-2021 Legend: TSCA - Mied-States?oxlc Substances Control Act Section 8(b) Inventory DSL/NDSL - Canadian Domestic Substances List/Non-Domestic Substances List EINECSIELINCS- European Inventory of Existing Chemical SubstanceslEuropean List of Notified Chemical Substances ENCS - Japan Existing and New Chemical Substances iECSC - China Inventory of Existing Chemical Substances KECL - Korean Existing and Evaluated Chemical Substances P1CCS - Philippines Inventory of Chemicals and Chemical Substances AICS - Australian Inventory of Chemical Substances US Federal Regulations SARA 313 Section 313 of Title ([[of the Superfutid Amendments and Reauthorization Act of 1986 (SARA). This product does not contain any chemicals which are subject to the reporting requirements of the Act and Title 40 of the Code of Federal Regulations, Part 372 SARA 3111312 Hazard Categories Acute health hazard Yes Chronic Health Hazard Yes Fire hazard Yes Sudden release of pressure hazard Yes Reactive Hazard No CWA (Clean Water Act) This product contains the following substances which are regulated pollutants pursuant to the Clean Water Act (40 CFR 122.21 and 40 CFR 122.42) EE RCLA This material, as supplied, contains one or more substances regulated as a hazardous substance under the Comprehensive Environmental Response Compensation and Liability Act (CERCLA) (40 CFR 302) US State Regulations California Proposition-65 This product contains chemicals known to the state of California to cause birth defects or other reproductive harm U.S. State Riaht-to-Know Regulations U.S. EPA Label information R1RWCTM NFPA HMiS Issue Date Date Health hazards 2 Flammability 2 Health hazards 2 Flammability 2 1-October-2021 Page 7 1 8 instability 0 Physical hazards 0 Physical and Chemical Properties - Personal protection X Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 HD TopCoat Slow Cure - Part B Date 1-October-2021 Revtslon Note COPY Disciaime The Information .provided In this Safety Data Sheet is correct to the best of our knowledge, Info the date of Its publication. The information given is designed only as a guidance for safe handling, use, processing, storage, transportation, disposal, and release and is not to be considered a warranty or quality specification. The Information relates only to the specific material designated and may not be valid for such material used In combination with any other materials or in any process, unless specified In the text. End of Safety Data Sheet Page 8 1 8 Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 PE-VIR.M : MOISTURE VAPOR BARRIER EPDXY DESCRIPTION PE-VRM is a clear 2-component,100% solids, low odor, low viscosity epoxy that is specifically formulated as a moisture barrier coating to treat new and existing concrete floors with high moisture and high pH. PE-VRM can be.used as a one -coat moisture vapor barrier coating suitable for various types of concrete, The low viscosity formula not only promotes deeper concrete penetration for superior substrate adhesion, but also generates higher propensity for sealing and blocking moisture drive than standard epoxy flooring product. RECOMMENDED USES • Manufacturing & Warehouse Floors • Laboratories • Mechanical Rooms • Animal Care Areas Shop Floors • Loading Docks • Pharmaceutical Plants • Retail Stores • Multiple -Unit Housing Institution Facilities • Excellent Moisture Blocker • Underneath any Coatings showing Concrete Contamination • Underneath Various Floorings such as carpet, Wood, Rubber, Vinyl, Tile, & Linoleum/PVT ADVANTAGES • 100% Solids, Low VOC, LOW odor Vapor Control for High Mioisture and High pH slabs • one -Coating Moisture Vapor Barrier Excellent Concrete Adhesion • Standard and Fast drying Times Low Viscosity for Deeper Concrete Slab Penetration • Controlled Vapor Pressure up to 25lbs. TECHNICAL. DATA ^`.:PAGKAGiNG _ .gallons & 15 galla COLOR Clew RRC.OMMENORC TH(CKiVESS16 m115 10i eartsAand i3 12 months In orIglnal unopened factorysealed:container's SN.ELF LiFE Protect from freezing Part;C 6 months In ariginai iittopen"ed packaging.. _ Store dry between 50 110° ;(IOA4°.C) MlX RAT10 MIAnits M x only 95 40 minutes VoC (GA) AP_P.LICATION TEMPERATURE "45°F (7°C) min. /"86 3ERYICE TIM: * ERATURE -00°F (40eC) min /48°F {�2o°C) max Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BCOA3 SURFACE PREPARATION CHECK FOR MOISTURE Concrete must be dry before application of this floor coating material. Concrete moisture testing must oc- cur. Calcium chloride testing or "In -situ" relative humidity testing Is recommended. Readings must be belc N the defined thres Id as specified for each Purepoxy system to be installed directly to the concrete substrate. CHECK THE TEMPERATURE & HUMIDITY Floor temperature and materials should be between 55°F (18°C Cd op-Cu ldi- ty must be less than 95%. Do NOT coat unless floor temperature is more than (5°F) over the dew point. SURFACE PREPARATION Requires ICRI CSP 3. This product requires proper surface profile to perform as expected. Substrate must be mechanically profiled (ASTM 4259-83), clean, sound, and dry. APPLICATION EQUIPMENT Tools; 3" Disposable brush, low speed drill (450 rpm) with a 3.5" Jiffler blade, 318" nap non-s The temperature of the (A) and (B) portions should be between 700 and 80°F (200-250C). MIX them separately to ensure a uniform consistency. For a 3 gallon kit add (Side-8) Into (SIde-A) in a 3.5 gallon bucket. Mix contents thoroughly until all components are completely incorporated and no streaking Is observed. Thinning is not recommended. The portions of each side is accurately measured to ensure optimum product performance. Pouring from one container to the other (boxing) during mixing is very helpful In ensuring complete mixing. Mix for 2 minutes. APPLICATION After mixing all contents as Instructed, Immediately pour out into a ribbon on the surface. Squeegee the material out evenly and check for desired film thickness by using a wet -film thickness gauge. Back -rolling and then cross rolling Is critical. Allow to dry mtnlmum of 12 hours before recoat. HEALTH AND SAFETY in case of skin contact, wash with water and soap. In case of eye contact, immediately rinse with water for at least 15 minutes. Consult with a doctor. For respiratory problems, transport victim to fresh air. Remove contaminated clothes and clean before reuse. Components A, B, and C contain toxic Ingredients. Prolonged contact of this product with the skin is susceptible to provoke an irritation. Avoid eye contact. Contact with may cause serious burns, Avoid breathing vapors release from this product. This product Is a strong sensitizer. Wear safety glasses and chemical resistant gloves. A breathing apparatus filtering organic vapors approved by the NIOSH/MSHA Is recommended. Predict suitable ventilation. *Consult the material safety data sheet for further information.* IMPORTANT NOTICE All statements, recommendations and technical information contained In this document are accurate to the best knowledge of PurEpoxy. The data relates only to the specific material designated herein. It may not be valid If used in combination with any other materlals. It Is the users' responsibility to verify suitability of this information for their own particular use, and to test this product before use. PurEpoxy assumes no legal responsibility for use upon these data. PurEpoxy assumes no legal responsibility for any direct, indirect, consequential, economic, or any other damage except to replace the product or refund the purchase price as set out In the purchase agreement. Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 17�ECRIPiyC>N TaRGINO01 POLYMER KLAKE m dre composed of water based resfi5 mater(ais, argdnlc mlrierpis, dddltive$, and vdriaus pigrnpnts 7171� unfq. pr9dg4t is lntegrafly ` pigmented, tyrlll►aritly'olored,;randaman shape, sized within a standardized rdnge, and can be custom blended tb gahleye optlrriai appearance and texture quallkles with a resinous flooring or woll- coo ting system..r {'oIYMR:FIAKEt"! are ayailable.tn over 150 color -styles dnd {x sizes mlxetl and matdtied`ta custom design your f(prsr and enhance tlny df�cor `: TVPICAL FLAKE SVS"i`EM For best results, a clear topcoat is recommended to fully encapsulate the FLAKE- and provide a durable wearing surface, CLSAN TOPCOAT(G) FLAKE"' " r a. ,Jr 3 SC �'4 ..� I Y" PI®MENTED SASECbAT• CONCRETE PRIMERISEALER (OPTiONAt) FEATURES & BENEFITS FLAKErM flooring enhances everyday spaces custom blends & color designs sample match Ing expertise over 150 color -styles in -stock Six unique sixes for optimum aesthetics FLAKE- texture provides anti -slip qualities. Water -based chemistry; iero VOC Formulated for optimal flexibility & strength UV tested lightfastness (see color palette ratings) Applies safely with speed & ease No minimum order quantities Lab-testod resin system compatibility ® Custom' packaging & labeling options Cost effective performance flooring solution DISCLAIMER: The Information set forth In this technical Data Sheet represents typical properties of the product described; the Information and typical values are not speclficatlons. Targlnol, Inc. makes no represehtdtioh orwarronty concerning the products, expressed orimplled, by this Technical Data sheet Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 S-,tr y� a �s k W wi& MINN peppermint F99710 . , detstreum ' F9962 0 Baby Blue Navajo Beige Cement Taupe F99B0.0 F9960 o F5262 o F9957 0 L' Seaspray F6101 o FawdorBlue n720 o Hoavon F0006 0 Skkyy Biva F9964 0 Stormy Blue F66210 Cobalt Blue F0963 0 Defray Blue 0140 o Royal Blue F0067 o Primary Blue F6604 • True Blue F1700 0 Bhlo ox M007.o • • Nypnotlo F0BB3 a Cosmo F9992 + Datkelue 1,1130 o Navy F9969 0 Sim ooveoray FI160 o Stane F90B70 Sommelier F0000 0 Tabu F5305 0 stldks&Stomas F5219 0 porpoise F6306 0. Scone F1790 0 6iM1-�IrlptiYent P2260 0 Ivory sugar Cooklo Buttdrrrtiik P1425 o F9009 o 1`9010 0 Funotionalaray sand Dune Fossil Potter F99610 F9094 F9911 F0981 poi In Butt B+Igd wigwam F9B01 o F66010 , . F1045 0 .. F51I6 0.- Alpaca White AntlqueWhlte•,WhI3pvr0my. F906B o F0060 0 FIND 0 Rhino bray F2669 0 MW am put lodray DWI<Oray Cyberspace online F2610 0 F9004 o F6[320 o 1,0003 0 MINIM e Charaoa M114 o F9902 o F1060 0 F1090 0 FLUORESCENT C M1 Blare orange- Chartreuse- Hot Fink• F4000 + F4040 + F4090 + RooketRedr Signal Groom' HerltOnBlue• 1:4120 a F4160 + F4180 + Granite _ Noutrai Gray F1410 o F6606 0 low Morning Fog Medium Gray F0966 o F1480 o N IN, 'space Gray Battleship Gray F6192 o F9956 0 White Lavender • Amethyst. F1920 0 F9966 0 F1020 + purple Hate AfricahMOISt Grape . 1:093 + F 999 + FBI04 0 Plum Rabin F0061 o F9076 0 PHOSPHORESCENT METALLIC Of ' Blue Glow Green Glow silver Metallla Folio + F912o + F3610 + Poop LightfastrlGss o = ,Mpderate Lightfastness _ Nohi3= Good Lightfaetness ' ''cater¢wtthpoarRghtfGstnecccue rwtrecommgvdAedfor appticatlonswlthdttectV-Uxeypow".tlghf[actnacc ratings are based on accelerated W tesBng U accordance with ASTM G155 (1,000 hour xenon Arc LlghtFxposure). page 314 Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 , ES1 :M I R SIMTHANE HWU SIMIRON SiMTHANE 14WU Is a unique high performance, three -component, high so(ids, low VOC urethane floor coat n�provtdes suparia resistance against abrasion, chemicals, corrosion, and UV exposure while imparting flexibility. This product is supplied as Is a neutral topcoat that has a satin finish with a light, consistent texture. -77 FEATUflIwS AND BENEFIT$ rvRECAMMENAD}l1SFS • Excellent Abrasion Resistance • UV Stable • Excellent Chemical Resistance • Flexibility • Satin Finish • High Solids, Low Odor Size / Finish Item Number 1 Gal Kit 40005030 Aremeasured 1-Gallon Kits. 1 gallon Slmthone HWU can he pigmented with 1 pint S/mlron U-Yint in colors Including: Here Oray, Light Dray, beck Oray, Sand.Who, White, Stack, & rite Red. • Topcoat for epoxy systems • Industrial & commercial warehouses • Manufacturing facilities • Automotive service areas • High traffic applications • Hangars • Shop floors • Garages F11�Si1 Will �15CA�tW 198R�a lratt Aw RA5 Gls"�'art 8 4 3 D)6B P�`t C Mixed Vls n4 760oP jRecotiittie+irledFiknnTt>Ickness _ 2 3mlla Solids by Volume VA So�ds:bywelOflt _ ; VDC VTA Method 24) 95 0/I. Dglng Schedule ®10 Mh 727 (22% 35% RN PARE 1 Or 4 SIMIRON J SIMTHANU", E HW.< B88-515.8775' 1 SIMIRON.COM Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 Coofficient of friction ANSiMSI 8101,1 Hardness, Pencil ASTM 03363 Tensile Strength ASTM 02370 W Resistance (gioss after 1000 hours In QUY) ASTM 0154 . SURFACE PR�PI�HATIDiV Concrete and coated concrete surfaces must be sound, dam, dry and free of contaminants such as dirt, dust, grease, oll, silicones and other contaminants that may negatively effect adhesion. MOISTURE- VAPOR BARRIERt A sulbbla moisture barrier must be In place for concrete stabs ongrede. If a moisture barter Is not in place, seasonal varistlons In ground moisture can cause excessive moisture vapor transmission (MVT) regardless of results measured prior to coating application, MVT rate must not exceed three pounds per 1,000 square feat per 24 hours, as directed by ASTM MOM The relative humidity (RH) of the stab must not exceed 7K as directed by ASTM F2170, If them Is a moisture situation in excess of the above rate, the use of Slmlron MVB Moisture Vapor Barrier Primer may be required. Consult a Slmlron Representative for details and application procedures. 12 mg lt�s 3Q;pi;Ca .BO ``PassesNt 411. 7,200 pal 811�':70> ExCxg(ent 8etetlk� 0'' Urine E Cole E lte(ehup.. _ MM16111 6* t *Staki *do foot, MKI Nam•-:. :.x E - Excellent 0.000d F a Fair NR G Not Recommend Nr:WMARE CONCR6I New concrete must be cured a minimum of 28 days and should meat moisture vapor twsmission NO and relative humidity (RH) thresholds es described In Surface Preparation section, Diamond grind or shotbtest to a CSP 1-3 surface profile. Refer to SSPC-SP13/NACE 6 or ICRI Technical Ouldeline No. 31 U. This product Is a topcoat, typically applied over an epoxy primer and basecoat. After the epoxy has hardaned, sand It with 80 grit screens to remove debris and smooth epoxy defects for best results. Vacuum and scrub or tack the area to remove all dust before topcoating. PRE-lIOrlSLY GOAYLPri SURFAG85' This product is a topcoat, typicatty applied over an epoxy system. Clean surface to prevent any contaminants from being spread/redistributed to a greater area being prepared. To recoat the existing surface, thoroughly sand/grind with 60 grit sandpaper or diamonds and clean existing coating to provide proper surface profile. Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BCOA3 I MKA I R0 IN] SIMTHANE Refer to the Spy sheet before use, Safety precautions must be strictly followed during storage, handling, and use. Personal Protective Equipment (PPE) should be worn at all times. PPE will include (but is not limited to): Safety glasses with side shield%, high-quallty nitrlle gloves, and properly btted NIOSH approved respirators. To acquire addltlonal Information or technical and safety data, please visit, www.simiron,cam. T MP�RA ARE Itutw 606 - 857 16' - 29'C Material 60' - 86'F 18' - 2910 *'Higher temperatures and humidity will shortan pot -life and working time. door temperature must he at feast fi degrees over the current dewpoint. APPLICATION EQUIPMNt Assemble all required application equipment. Equipment will include (but is not limited to), • Drip andJiftyeitype mixing blade • High quality non -shed 3/6" nap roller covers • Edge rollers & chip brushes • Rotter pans HWU ---_------- "Olry 1. Pre -mix Part B with a with a drill ana j117 type mixing de 0 low speed. If pigmenting, add a pint of U-Tint per gallon kit and mix until uniformly dispersed. Slowly add Part C Filler and mix for 3 minutes until thoroughly blended. Add partA and mix for 3 additional minutes. Do not mix more than 1 kit at a time. 2. Using a brush, cut in any edges and areas that will, not allow coverage with a roller. He careful to apply thin around all floor obstructions and at the base of a cove (floor and wall Junction). Material applied to cove or vertical surface will run, teaving a pool at the base. These areas can be rolled out with a small roller designed for edging. 3. Pour mixed material into a roller pan and apply with a 3/8" nap roller cover at 600 sq. ft./gat. It you apply thicker than recommended, you are more likely to create: bubbles, soft film, texture and gloss variation. 4. Dip the roller In the material and lightly roll off excess coating in the roller pan, Ro(( across your area right to (eft or (aft to right, 2 parallel paths on the concrete that are approximately 8-10 feet in length. Repeat the dip and roll process, so there are 4 adjacent roller paths in front of the applicator. Agitate the mixed material In the roller pan frequently, as the Part C fitter can settle to the bottom of the pan. Rolling out excess fitter from the bottom of the ratter pan can impact color and texture. 5, Back -roll the coating up and back across the previously applled paths (perpendicular) using a V-shape pattern to evenly spread the material and remove roller tines. There should be just enough material on the floor to cover the area. The final rolling passes should be straight up and back. Pulling material down toward the applicator and reaching to overlap at least 1 ft, into the previously applied area will allow better blending of application marks. 6. Move over or down the floor and repeat steps 4 and 5. To help prevent visual differences in application be sure to minimize the time between tle-Ins. Use control joints or natural breaks as breaking points between mixes. 7. To better blend overlap and application marks, have a separate person finish roll no more than 20 minutes behind the other rollers on spiked shoes by pulling a wet roller across the entire area in the same direction as the original roper passes. The material will not flow out, so the coating wilt cure with any defects that are visible. Reroll areas that do not look satisfactory. 8. Do not back roll coating that has begun to tack up. This could result in an orange peat texture andlor a whitelah haze in the coating. Applying the coating thicker than recommended or rolling the material when sticky will cause bubbles, roller lines/ inconsistent appearance, SIMIRON,,) SIMTNANE HWa 866.515.0775, , F,IMIflON.CGM PAfiE 3 OF R , E velo e ID: D6082DCi-252A-402D-B8EC-OECD6C4BC9A3 SIMTHANE HWU . CLEAN UP ANp AISPOSAL Clean up mixing and application equipment Immediately after us*. Use toluene, acetone or xylene; do not use alcohol, Follow solvent manufacturer's safety Instructions. 9e sure to follow all local, state and federal regulations when disposing of materials. 12 months from date of manufacture when I unopened container at 60-F - 85`F (16T - 2910) In a dry location with humidity below 65%,. A Do not allow materials to freeze. ROW', ` _ LIMiT�A WARRANTY > # Tb maintain the appearance and extend the llfa of the newly seatedsurface, It is Imperative to have a routine maintenance program. Dirt and debris that Is tracked over a finished Mor will quickly scratch and dull the surface. Place walk -off mats at entrances. Sweep and mop/scrub floors regularly using soft bristtes/pads and a mild cleaner. Some cleaning products and equipment or improper use of these can damage a surface. Remove splits quickly to minimize damage and/or stains. For systems that support parked vehicles or other heavy Items on rubber wheats, place a small piece of nonporous material, such as sheet metal or plexiglass between the tires and floor to prevent tiro marks. Reapplication may be necessary In heavy traffic areas. SIMIRON warrants this product to be free from defect In the material that affects Its performance for a period of one year (from date of purchase). SIMIRON wilt replace at no charge the quantity of the Coating that SIMIRON determines has failed to perform, as the sole and exclusive remedy for any breach of this warranty and/or any other defect or failure of the coating, Proof of purchase Is required. Cost of taborfor application of any product specifically is excluded. Warranty is vold It Simiron products are mixed with or used in conjunction with materials that are substituted for Simiron products. Warranty is nontransferable. 77 LIMITATIONS . =x . ?�CHNiCAi ASSISTANCE A This thin topcoat will not cover/hide damage and defects In previous coatings or basecoats it Is going over. A The high solids formula may not adhere to epoxies that are not soft and not sanded well. A Do not apply at temperatures and thicknesses not recommended. A Do not make partial mixes. A Do not apply over loose or unsound concrete, asphalt or bitumen substrates, glazed file or nonporous brick and tile, magnesite, copper, metal, polyesters, or elastomeric membranes, A Moving joints and shrinkage cracks may raftect through system. Joints that are designed to move may reflect through the finished flowing system if the are not honored, A Applying thicker than recommended, allowing material to pool, or rolling into late may leave a white, hazy appearance, A Tire marking may occur. CORPORATE OFFICE Simiron Inc 3000 Rasaardh Drive SIMIRU"� Rochester Hills, MI 483093580 USA (248) 686.3600 / (866) 51M775 , Toll Free: 1.866.515,0775 /+1,248A6.3600 Pa7DrlVTe0W;1oAA/LUlA IM1cir6 W,, All won mtkn prwldad by Slmlrofy Ina cincwning 81fWmn produA lnduding but not Um (fed tor, any mmmmdWonr and advla re{ednD to du appllcadon and use of almban pmdtxta, to phw In pond to th band on Srmlron's custom-#Am*nce andknoMrdpe of lb prooix u *w prcvxr1ysWs4 handrr4snd+Wpf kdWx*r naafi coW*M in accordance Mitt sknk-s ftWMXtiau. In prvctk►, the dM+rmca In mawfs* subs bvta, storage and Wd kV condhkau. actual ma0$ms and OW factors outO* ofSimlron's mov(an such that SlW= MWas rt4WHY for the provbbn of suds ink madon 0MC4 MMWI ndetkras or kwrm"ons Wow to fta products. The wn of Sknkw pradud(s) fw'suhabft for the intended apptkvdon and porpoae 6efory pmcfedkv wfdh the NU applkOW of thtprodvlifal. sknlron rnerves iM rfoht to dwve flu pmpxttln of In prWuds wftW not►ar. All Slmt= pmduct(s) my sttOa to Its foment trmu and mndttkm of sate VAkA n e avatlaWa by salting (NO 61689'7B. SIMIROW l 41M1 HANG HWU.* 88a-Fh15.8775 f SIMIRON.00M PAOG, A'OF'4 Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 PRODUCT DATA SHEET Sikafloor°-24 NA PurCem° FS ADVANCED GENERATION, FAST SET, SELF LEVELING, THIN LAYER POLYURETHANE/CEMENT SCREED FOR GENERAL INDUSTRIAL AND COMMERCIAL USE PRODUCT DESCRIPTION Slkafloorm-24 NA PurCem° FS is a state of the art, phthalate -free, water dispersed polyurethane based /cement and aggregate screed, applicable at ' thicknesses ranging from 80 to 160 mils (2 to 4 mm). It is designed to be installed as a self leveling floor or topping that provides an easy -to -clean, smooth surface with slip resistance values and is typically used for general, industrial applications. Sikafloor®-24 NA PurCem® FS represents superior polyurethane/cement technology, combining easier --application, resistance to blistering and improved performance. USES, Sikafloor®-24 NA PurCem® FS may only be used by experienced professionals. Typically used in areas of medium to heavy loading and abrasion, to provide a smooth, flat and thin self - leveling layer in general industrial areas, including warehouses, production facilities, laboratories and workshops, either with or without a Sikafloor® sealer top coat. As thin layer, flat but slip -resistant screed in commercial environments, with a suitable UV -stable Slkafloor sealer for retention of aesthetics. As broadcast receiving coat, flat but slip -resistant screed in commercial envlronments,with a suitable UV - stable Sikafloor sealer for retention of aesthetics. r When used as a base for MVT system, total thickness must be 1/8-inch (3.2mm). Product Data Sheet Sikaflopr'-24 NA PurcamO FS August 2020, Version 01,07 ON51402002OWW41 1/7 CHARACTERISTICS / ADVANTAGES • Can be applied on green concrete, typically 7-10 days. Full 28 days cure time is not necessary. • Can be applied over partially cured concrete -substrates (> 4% mass (pbw —part by weight) as measured with Tramex® CME/CMExpert type concrete moisture meter surface moisture). • Can be applied to concrete substrates where <100 relative humidity is measured as per ASTM F2170. • Substrate has tensile bond strength in excess of 218 psi (1.5 MPa), Substrate has.tensile bond strength in excess of 218 psi (1.5 MPa). • Resists a very wide range of organic and inorganic acids, alkalis, amines, salts and solvents. Consult Sika Technical Service for full details. Refer to the Slkafloor - 24 NA Purcem FS Chemical Resistance Chart. • Similar coefficient of thermal expansion to concrete allowing movement with the substrate througH ' normal thermal cycling. it will perform and retain Its physical characteristics'through a wide temperature range from -40 °F (-40 °C) up to 248 °F (120'C). •'Steam cleanable at 80 to 160 mils (2 to 4 mm). . thickness. • Non -tainting, odorless. ■ Behaves plastically under impact / deforms but will not crack or debond. • High abrasion qualities result from its aggregate structure. • Extra Expansion Joints are not necessary, maintain and extend existing expansion Joints up through the Slkafloor PurCem Flooring System. Minimal maintenance costs, superior life cycle cost advantage versus tile. • Meets the requirements of USDA for use in food plants. Docusign Envelope ID: D6082DCI-252A-402D-B8EC-OECD6C4BC9A3 Service Temperature The product is suitable for use when exposed to continuous te mpPat jrP.-;. : ara.ture is 41'F "W 7 Y wet or dry, of up to 249'F (120*C). The minimum service temp (5'C) at 2.0 mm and 14'F(-I0'C) at 4.0 mm. Softening point 266-F (130-C) Mixing Ratio Components A:B:C = (2k 2B: 1C) = Mix full units only. Coverage SikafloorO-24 NA PurCem® FS Scratch coat: Where surface/substrate profile requires *a and as a base for smooth systems: Approx..215 ft 2/unit (20m'2/unit) @ 40 mils (1 mm) per coat Screed: These figures do not allow for surface porosity, profile or wastage'. Approx. 107 W (10 ml) per unit at 80 TI(s.(2.mm) Approx. 85ft?- (7.9 ml):per. unit at1CO mils (2.5 mm) Approx. 71 ft2 (6.6 m2) per unit at 120 HIS (3 mm) Broadcast Application: Primer/Scratch Coat (where surface/substrate profile requires Body Coat: Approx. 107 ft2 (10 M2) per unit at 80 mils (2 mm) Br6adcast to excess Substrate Temperature Mlnim.um/Maximum 40*/85'F (4*/30*C) Pat Ufa Material Temperature time +50'F (IO'C) - 25-30 minutes +68-17 (20-C) - 15-20 minutes +86'F (30'C) - 5-10 minutes Cure Time Substrate Foot traffic Ught traffic Full cure Temperatur +50*F (10*C) — 18 hours — 24 hours 7 days. +68*F (20*c). — 8 hours — 12 hours 4 days +86-F (30-C) — 5 hours - 12 hours 3 days Waiting RecoatIlm" Before applying Slkafloorl-24 NA ?UTCeM41 FS when a scratch primer and sealer coat Is used allow. Ambient & Substrate Minimum Maximum Temperatur ._ +507 10-C) 8 hours 7 days +68*F (20'C) 4 hours 3 days +86*F (30*C) 3 hours 2 days Product Data Sheet Slkefloor'•24 NA PurCmg FS August 2020, Verilon 01.07 020814020020000041 BUILDING TRUST 3/7 Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 APPUCA ON Priming of concrete substrates is not usually required under typical circumstances'. However, due to variations In concrete quality, surface conditions, surface preparation and ambient conditions, reference test areas are recommended to determine whether priming Is required to prevent the possibility of blisters, debonding, pinholes and other aesthetic variations,. Note: Given the fluidity and relatively thin -layer Installation of Sikafloor®-24 NA PurCem® FS a primer for porous substrates or a scratch coat where the surface profile demands such, are highly recommended. Smooth Appitcatton Primer For smooth applications, a primer or scratch is required. Mix and apply a primer coat of Slkafloor-31NA PurCem FS at a consumption of approximately 165 ft2/unit 6 5.3 m2/unit) per coat to achieve a complete 10 mils VA. coverage of the substrate, using a short or medlum nap roller. Work the priming resin well into the surface, making sure the floor Is fully wetted and then pull back lightly with the roller to the required thickness. Prime retaining (anchor) grooves but do not fill. Allow a cure period of at least 3 hours at 68'F (20°C) before application of the smooth screed mortar. Scratch Coat (000nal) Where the surface profile requires such.and where a flat floor is intended, mix and apply a scratch coat of Sikafloor®-24 NA PurCem® FS using steel trowels to spread the materials at consumption of approximately • 215 ft2/unit (20 m2/unit) per unit, achieving a minimum 40 mils (1 mm) thickness. This application must be applied to seal the concrete surface, fill in surface - Irregularities; including pock marks, -non-moving control joints and cracks., (Note: Should the scratch coat at 40 mils (1 mm) not fill and level the irregularities, additiona coats can be applied, observing the necessary inter -coat curing times). Allow a cure period. of at least 3 hours at 20°C (68°F) before application of the screed. Smooth Screed Mix and pour the Sikafloor°-24 NA PurCem® FS onto the floor. Spread to the desired thickness, from 80 -160 mlls (2 - 4 mm), at approximate consumptions of 107 ft2 (10 m2) per unit at 80 mils (2 mm) to 53.5 ft2 (5 m2) per unit at 160 mils (4 mm), using a notched trowel or pin or cam gauge rake. Note: Take care to spread freshly mixed materials across the transition of previously applied mixes before the previously applied material begins to set. Immediately spike roll the surface to release trapped air in the matrix. Roller spikes must be at least three times longer than the applied product thickness. Allow a minimum 18 hours cure period at 68°F (20°C) before foot traffic. Product Data Sheat SikafloorO.24 NA PurCam* FS August 2020, Version 01,07 020814020020000041 Broadcast Application 125 mlis (3 mm) Primer COPY Priming or scratch coat of concrete substr tea is no usually required under.typlcal circumstanc ns. 1 Iaooemrpr, due to variations In concrete quality, surface conditions, surface preparation and ambient conditions, reference - test areas are recommended to determine whether priming is required to prevent the possibility of blisters, debonding, pinholes and other aesthetic variations. For a primer, use either Slkafloor-31NA PurCem •FS or Sikafioor®-24 NA PurCem® FS Scratch Coat..; Mix and pour the Slkafloor®-24 NA PurCem® FS materials on the floor. Spread mixed material to approximately107 ft2 ,(10 m2) per unit at 80 mils (2 mm) using a screed gauge rake or trowel. Take care to spread newly mixed materials across the transition of previously applied mixes before the, surface begins to set., Immediately spike roll the surface to release trapped air in the matrix. Broadcast selected aggregate to rejectlo.n. Aggregate must fall vertically to avoid surface defects / do not broadcast up to the transition line of new mixes, always broadcast 2 - 3 feet beyond the wet edge. Allow . broadcast surface to cure sufficiently to be able to resist: foot traffic without damaging the surface. Remove excess aggregate by sweeping or vacuuming until:. surface is free of all loose particles and dust. A topcoat of Sikafloor-31NA PurCem. FS or, other topcoats depending,on applications can be applied to lock in.the aggregate. Allow a minimum 24 hour cure period at 682F (209C) before light traffic after the Slkafloor-31NA PurCem FS is applied. . BUILDING TRUST 5/7 Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 LEGAL DISCLAIMER • KEEP CONTAINER 11GHTLY CLOSED • KEEP OUT OF REACH OF CHILDREN • NOT FOR INTERNAL CONSUMPTION • FOR INDUSTRIAL USE ONLY • FOR PROFESSIONAL USE ONLY Prior to each use of any product of Sika Corporation, its subsidiaries or affiliates ("SIKA"), the user must always read and follow the warnings and Instructions on the product's most current product label, Product Data Sheet and Safety Data Sheet which are available at usa.sika.com or by calling SIKA's Technical Service Department at 1-800-933-7452. Nothing contained in any SIKA literature or materials relieves the user of the obligation to read and follow the warnings and instructions for each SIKA product as set forth in the current product label, Product Data Sheet and Safety Data Sheet prior to use of the SIKA product. SIKA warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical properties on the current Product Data Sheet if used as directed within the product's shelf life. User determines suitability of product for intended use and assumes all risks. User's and/or buyer's sole remedy shall be limited to the purchase price or replacement of this product exclusive of any labor costs. NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALL APPLY INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR .PURPOSE, SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES, SiKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS. Sale of SIKA products are subject to the Terms and Conditions of Sale which are available at https://usa.sika.com/en/group/SikaCorp/termsandcond[tions,html or by calling 1-800-933-7452. Sika Corporation 2o1 Polito Avenue Lyndhurst, NJ 07071 Phone:+1-800.933-7452 Fax:+1-201.933-6225 usa.slka.com Product Data Sheet Sikafloor`•24 NA PurCetrt* FS August 2020, Version 01.07 02081402DO20ODD041 7/7 slka Mexican $A de CV. Carretera Libre Celaya Km.8.5 Fracc. Industrial ealvanera Corregldora, Queretaro C.P. 76920 Phone: 5244223858M Fax: 52 442 2250537 �I Sika(Ioor-24NAPurC emFS-en-US-(08.2020)-i-7,pdf BUILDING TRUST A Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 PRODUCT DATA SHEET Si kafloor°-510 Abrasion and UV Resistant Polyaspartic Resin System PRODUCT DESCRIPTION Sikafloor®-510 is a clear two -component, solvent -free, high solids, low -viscosity, high strength, polyaspartic resin system. Sikafloor®-510 is designed to be installed as a clear topcoat over a quartz or flake broadcast system where a low VOC, quick cure, flexible, UV resistance finish coat is necessary. Slkafloor®-510 Is available in clear or with SikafioorO Urethane Color Additive to achieve a variety of colors. USES Sikafloor®-510 may only be used by experienced professionals. Typically used in decorative applications, chemical storage areas, warehouses, washrooms, laboratories, food preparation areas and chemical process plants. PRODUCT INFORMATION CHARACTERISTICS / ADVANTAGES • Resists a very wide range of organic and Inorganic acids, alkalis, amines, salts and solvents. Refer to Sikafloor chemical resistance guide. • Cures quickly, fast turnaround • Durable, Impermeable and seamless • Superior mechanical resistance. • Excellent chemical resistance • Superior aesthetic finish. ■ Excellent UV resistance ■ Low maintenance. • Does not support growth of bacteria or fungus. • High density prevents dirt penetration, which provides easy cleaning. = Solvent -free. ■ Meets USDA requirements for incidental food contact Packaging Component A: 5 US gal. (18.9 L) Component B: 3.33 US gal. (12.6 L) Components A+B: 8,33 gal. (31.5 L) Appearance / Color Clear or pigmented only with SlkafloorO SCO Color Additive; 1 quart (1.0 L) size Shelf We Components A+B:12 months in original unopened packaging Storage Conditions Store dry between 50-77 "F (10-25 °C). Protect from freezing Volatile organic oompound (VOC) con- 16 g/I tent 17 g/1 with Slkafloor°-372 Urethane Accelerator 17 g/I TECHNICAL INFORMATION Product Data Sheet Slkafaor■-510 August 2018, V6nlan 01.01 02081204003000W02 1/5 Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 preparation and on the moisture content. MIXING Mixing Ratio - 3 -.2 by volume. For bulk packaging, when not mixing full units, each component must be pre -mixed separately to ensure product uniformity. Clear Resin: Premix each Component separately. Empty Component B (Hardener) in the correct mix ratio into Component A (Resin). Mix the combined components for at least 3 minutes using a low speed drill (300 - 450 rpm) and Exomixer or Jiffy type paddle suited to the volume of the mixing container to minimize entrapped air. Be careful not to introduce any arr bubbles while mixing. Make sure the contents are completely mixed to avoid any weak or partially cured spots In the coating. During the mixing operation, scrape down the sides and bottom of the container with a flat or straight edge trowel at least once to ensure complete mixing. Field Pigmented, If color is desired, Sikafloor' SCO Additive is added to Component at a rate of 1 quart per2.5 mixed gallons (i.e. Components A+B) for all colors. Mix Component A and Sikafloor' Urethane Color Additive for 2 minutes or until a uniform color is achieved with a low speed drill (300-450 rpm) and Exomixer or Jiffy type paddle suited to the volume. Empty Component B (Hardener) in the correct mix ratio to Component A (Resin) and mix for additional 2 minutes. Be careful not to introduce any air bubbles while mixing. Make sure the contents are completely mixed to avoid any weak or partially cured spots In the coating. During the mixing operation, scrape down the sides and bottom of the container with a flat or straight edge trowel at least once to ensure complete mixing. APPUCATION As a pigmented topcoat/sealer coat for smooth or broadcast finish: Squeegee and back roll Sikafloor®-510 to provide a uniform coverage without ponding at a thickness of 10-15 mils (160-107 W/gal). if required, repeat this procedure for a second coat. As a dear topcoat for a broadcast quartz or flake system: Squeegee and back roll Sikafloor)-510 to provide a uniform coverage without ponding at a thickness of 10-15 mils (160-107 W/gal). If required, repeat this procedure for a second coat. As a stand-alone double broadcast quick cure decorative quartz and flake system: Step 1: Primer - Apply a neat coat of Sikafloor®-510 on a prepared substrate as a primer using a squeegee and roller without ponding at 5-10 mils (160-320 W/gal). Note: When using Sikafloor®-510 as primer extra precaution has to be taken on the substrate preparation Product Data sheaf Slkafloor`310 August201a, Version 01.01 020912040030000002 3/5 and moisture content. Step 2; First Broadcast Application -SqueE gee and back roll Sikafloor®-510 to provide a uniform c( v"COPY without ponding at a thickness of 10-15 W/gal). Broadcast pre -blended clecoratIvE flakes or colored quartz aggregates into the binder To slaturation. Broadcast in a manner so that the flakes or colored quartz aggregates fall vertically into the binder. Broadcast to rejection. Ensure that broadcast flakes/aggregates cover entire surface. Allow broadcast system to cure sufficiently to be able to resist foot traffic without damaging the surface. Remove excess flakes/aggregates from the surface. Removal of excess flakes/aggregates Is carried out by sweeping up the flakes/aggregates, followed by vacuuming, until surface is free of all loose particles and dust. Step 3: Second Broadcast Application - Squeegee and back roll Sikafloor®-510 to provide a uniform coverage without ponding at a thickness of 10-15 mils (160-107 ft 2/gal). Broadcast pre -blended decorative flakes or colored quartz aggregates into the binder to saturation. Broadcast in a manner so that aggregates fall vertically into the binder. Broadcast to rejection. Ensure that broadcast flakes/aggregates cover entire surface. Allow broadcast system to cure sufficiently to be able to resist foot traffic without damaging the surface. Remove excess flakes/aggregates from the surface. Removal of excess flakes/aggregates is carried out by sweeping up the flakes/aggregates, followed by vacuuming, until surface is free of all loose particles and dust. Step 4: Finish Coat - Squeegee and back roll Sikafloorm- 510 to provide a uniform coverage without ponding at a thickness of 10-15 mils (160-107 W/gal). When required, repeat this procedure for a second coat. LIMITATIONS Notes on Umitations; Prior to application, measure and confirm Substrate Moisture Content, Ambient Relative Humidity, Ambient and Surface Temperature and Dew Point. During installation, confirm and record above values at least once every 3 hours, or more frequently whenever conditions change (e.g. Ambient Temperature rise/fall, Relative Humidity increase/decrease, etc.). Substrate Moisture Content: Moisture content of concrete substrate must be S4 % by mass (pbw - part by weight) as measured with a Tramex® CME/CMExpert type concrete moisture meter on mechanically prepared surface according to this product data sheet (preparation to CSP-3 to CSP-4 as per ICRI guidelines). Do not apply to concrete substrate with moisture levels >4 % mass (pbw- part by weight) as measured with Tramex® CME/CMExpert type concrete moisture meter. if moisture content of concrete substrate is >4 % by mass (pbw-- part by weight) as measured with Tramex® BUILDING TRUST Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 CME/CMExpert type concrete moisture meter, use Sikafloor®1610 or Slkafloor® PurCem" 22NA or 24NA. When relative humidity tests for concrete substrate are conducted per ASTM F2170 for project specific requirements, values must be S85 %. If values are >85 according to ASTM F2170 use Sikafloor® 1610 or Sikafloor° PurCeml 22NA or 24NA. ASTM F2170 testing is not a substitute for measuring substrate moisture content. Use a Tramex® CME/CMExpert type concrete moisture meter as described above Material Temperature: Precondition material for at least 24 hours between 65 °F to 75 °F (18-24 'C) Ambient Temperature: M inimu m/Maximum 50/85 ' F (10/30 'C) Substirate Temperature: Minimum/Maximum 50/85 'F (10/30 'C). Substrate temperature must be at least 5 'F (3 'C) above measured Dew Point. Mixing and Application must adhere to Material, Ambient and Substrate temperatures listed above or a decrease in product workability and slower cure rates will occur. Relative Ambient Humidity: Minimum ambient humidity 30 %/Maximum ambient humidity 75 % (during application and curing) Note: Low Relative Ambient Humidity may result in slower cure. Dew Point: Beware of condensationi The substrate must be at least 5 'F (3 'C) above the Dew Point to reduce the risk of condensation, which may lead to adhesion failure or "blushing" on the floor finish. Be aware that the substrate temperature may be lower than the ambient temperature, Mixing: Do not hand mix Sikafloor® materials, Mechanically mix only. Do not thin this product, Addition of thinners (e.g. water, solvent, etc.) will slow cure and reduce ultimate properties of this product. Use of thinners will void any applicable Slka warranty, Application: If Sikafloor)-5101s used as a primer, apply the coating to the prepared substrate using a squeegee and back roll to provide uniform coverage. Ensure that the coating is pore -free and pinhole -free and provides uniform and complete coverage over the entire substrate. If necessary, apply an additional coat to ensure the coating Is pore -free and pinhole -free and provides uniform and complete coverage over the entire substrate. • Do not apply while ambient and substrate temperatures are rising, as pinholes may occur. • Ensure there is no vapor drive at the time of application, Refer to ASTM D4263, may be used fora Product Dati Sheet SIkal1oor••S10 August 2018, Version DIM 07081204003000M02 4/5 visual indication of vapor drive. • Do not apply Slkafloor® to concrete su containing aggregates susceptible to AS 2 (Alkali Silica Reaction) due to risk of natural alkali re i ri o below the Slkafloor product after appii 3 I concrete substrate has or is suspected have ASR (Alkali Silica Reaction) present, do not pConsult with design professional prior to use. • Any aggregate used with Slkafloor® systems must be non -reactive and oven -dried. This product is not designed for negative side waterproofing, • Use of unvented heaters and certain heat sources may result In defects (e.g. blushing, whitening, deponding, etc.). • Beware of air flow and changes in air flow. Introduction of dust, debris, and particles, etc, may result In surface imperfections and other defects. • For professional use only by experienced applicators. BASIS OF PRODUCT DATA Results may differ based upon statistical variations depending upon mixing methods and equipment, temperature, application methods, test methods, actual site conditions and curing conditions. OTHER RESTRICTIONS See Legal Disclaimer. ENVIRONMENTAL, HEALTH AND SAFETY Component A. Warning: Corrosive, irritant, sensitizing contains Aldamine (CAS 54914-37-3). In contact with skin and eyes cause severe burns, Causes irritation of eyes, skin and respiratory tract. Prolonged or repeated contact may cause an allergic reaction and sensitization, Harmful If swallowed. It releases concentration of vapors, the inhalation affects is harmful and can be fatal. Strictly follow the handling and storage instructions, Component B. Warning: Irritant and sensitizing. Causes irritatlon to the skin, and in the respiratory tract. May cause allergy to skin, respiratory tract and sensitization after prolonged and repeated contact. Harmful If swallowed. It releases concentration of vapors, the inhalation affects is harmful and can be fatal. Strictly follow the handling and storage Instructions. First aid. BUILDING Docusign Envelope ID: D6082DC1-252A-402D-B8EC-OECD6C4BC9A3 Eyes. Wash with clean water for 15 minutes. Remove contaminated clothing and wash skin thoroughly with water for 15 minutes with soap and water. Inhalation. Move to fresh air. Do not Induce vomiting. Dilute with water. Contact a doctor as soon as possible. In all cases, contact a physician immediately if symptoms persist. Sika corporation Sika Mexican SA de C.V. 201 Polito Avenue Carretere Libre Celaya Km. 8.5 Lyndhurst, Nl07071 Pracc.Industrial 8alvanera Phone:+1-800.933-7452 Correg(doru,Queretaro Fax:+1-201-933-6225 C.P.76920 usa.slka.conn Phone: 52442 2385800 Fax 52442 2250537 Product DaN Sheet 91kailoor••310 August 2018, Verslon 01,01 02081204003D000002 5/5 LEGAL DISCLAIMER • KEEP CONTAINER TIGHTLY CLOSED Cory • KEEP OUT OF REACH OF CHILDREN • NOT FOR INTERNAL CONSUMPTION • FOR INDUSTRIAL USE ONLY • FOR PROFESSIONAL USE ONLY Prior to each use of any product of Sika Corporation, its subsidiaries or affiliates ("SIKA"), the user must always read and follow the warnings and instructions on the product's most current product label, Product Data Sheet and Safety Data Sheet which are available at usa.slka.com or by calling SIKA's Technical Service Department at 1-800-933-7452. Nothing contained in any SIKA literature or materials relieves the user of the obligation to read and follow the warnings and Instructions for each SIKA product as set forth in the current product label, Product Data Sheet and Safety Data Sheet prior to use of the SIKA product. SIKA warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical properties on the current Product Data Sheet If used as directed within the products shelf life, User determines suitability of product for intended use and assumes all risks. User's and/or buyer's sole remedy shall be limited to the purchase price or replacement of this product exclusive of any labor costs. NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALL APPLY INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS. Sale of SIKA products are subject to the Terms and Conditions of Sale which are available at https://usa.sika.com/en/group/SikaCorp/termsandconditions.htmi or by calling 1-800-933-7452. Slka noor510•en-Us-(08.201a)•1.1.pdf E. BUILDING TRUST W-- EST BEND Bond Number: 2631006 KNOW ALL BY THESE PRESENTS, That We, Black Diamond Wl LLC as Principal, and WEST BEND MUTUAL INSURANCE COMPANY, a corporation organized under the laws of the State of Wisconsin and having its principal office in West Bend, Wisconsin, in said State, as Surety, are held and firmly bound unto Ci of Oshkosh as Owner, in the full and just sum of Five Percent ( 5 %) of amount bid for the payment whereof said Principal binds its heirs, administrators, and executors and said Surety binds itself, its successors and assigns firmly by these presents WHEREAS, said Principal has submitted to said Owner a bid or proposal for Installation of ep2U floor coating: various a buildings NOW THEREFORE, THE CONDITION OF THIS OBLIGATION IS SUCH that if within Sixty days hereof and in accordance with said proposal a contract shall be awarded to said Principal and the said Principal shall enter into a contract for said work and shall furnish bond with surety as required for its faithful performance then this obligation shall be void, otherwise remain in full force and virtue. Signed and Sealed this 5 day of November 20 24 Principal: Black Diamond L B . (SEAL) Witness: NamIT yped. Andrew Nick®lain Preflidnt Title Surety: West Ben utual In ance Company (SEAL) Witness: Name T ed: THOMAS PUPETPR f Title Agency Name: ANSAY & ASSOCIATES LLC Address: 430 N KOELLER ST PO BOX 3387 OSHKOSH. WI 54902 Phone Number: (g20) 235 646t MICHIGAN ONLY: This policy is exempt from the filing requirements of Section 2236 of the Insurance Code of 1956, 1956 PA 218 and MCL 500.2236. NB 0192 04 22 Page 1 of 1 1900 S 18th Avenue I West Bend, WI 53095 1 Phone: (800) 236-5010 1 Fax: (877) 674-2663 1 www.thesilvedining.com WEST BEND" POWER OF ATTORNEY Bond No. 2631006 Know all men by these Presents, that West Bend Insurance Company (formerly known as West Bend Mutual Insurance Company prior to 1/1/2024), a corporation having its principal office in the City of West Bend, Wisconsin does make, constitute and appoint: THOMAS PUPETER lawful Attorneys) -in -fact, to make, execute, seal and deliver for and on its behalf as surety and as its act and deed any and all bonds, undertakings and contracts of suretyship, provided that no bond or undertaking or contract of suretyship executed under this authority shall exceed in amount the sum of: Thirty Million Dollars ($30,000,000) This Power of Attorney is granted and is signed and sealed by facsimile under and by the authority of the following Resolution adopted by the Board of Directors of West Bend Insurance Company by unanimous consent resolution effective the 15t day of January 2024. Appointment of Attorney -In -Fact The president or any vice president, or any other of of West Bend Insurance Company may appoint by written certificate Attorneys -In -Fact to act on behalf of the company in the execution of and attesting of bonds and undertakings and other written obligatory instruments of like nature. The signature of any officer authorized hereby and the corporate seal maybe affixed by facsimile to any such power of attorney or to any certificate relating therefore and any such power of attorney or certificate bearing such facsimile signatures or facsimile seal shall be valid and binding upon the company, and any such power so executed and certified by facsimile signatures and facsimile seal shall be valid and binding upon the company in the future with respect to any bond or undertaking or other writing obligatory in nature to which it is attached. Any such appointment maybe revoked, for cause, or without cause, by any said officer at any time. Any reference to West Bend Mutual Insurance Company in any Bond and all continuations thereof shall be considered a reference to West Bend Insurance Company. In witness whereof, West Bend Insurance Company has caused these presents to be signed by its president undersigned and its corporate seal to be hereto duly attested by its secretary this 1st day of January 2024, SU Attest C�nlstU0lui (�• 4WNGiA `�u`�OooPPo'�rF C\�; Christ4her C. ZWygalrt = Q7 j SEAL O Robert J. Jacques Secretary �� N c President State of Wisconsin County of Washington On the 1st day of January 2024, before me personally came Robert Jacques, to me known being by duly sworn, did depose and say that he is the President of West Bend Insurance Company, the corporation described in and which executed the above instrument; that he knows the seal of the said corporation; that the seal affixed to said instrument is such corporate seal; that is was so affixed by order of the board of directors of said corporation and that he signed his name thereto by like order. ,IIIIIIIII,,, �."% %BENZ, V130G Dead orporate Attorney Notary Public, Washington Co., WI My Commission is Permanent The undersigned, duly elected to the office stated below, now the incumbent in West Bend Insurance Company, a Wisconsin corporation authorized to make this certificate, Do Hereby Certify that the foregoing attached Power of Attorney remains in full force effect and has not been revoked and that the Resolution of the Board of Directors, set forth in the Power of Attorney is now in force. Signed and sealed at West Bend, Wisconsin this 5th day of November , 2024 \\Illunl,,, _ro: i0; SEAL ' 3 = Christop er C. Z4 a -N Secretary 1900 S 18th Avenue I West Bend, WI 53095 1 Phone: (800) 236-5010 1 Fax: (877) 674-2663 1 www.thesilverlining.com C WEST BEND" r. Bond Number 2631006 Performance Bond KNOW ALL MEN BY THESE PRESENTS: That Black Diamond WI LLC Of PO Box 7263 Appleton, WI 54912-7263 (Name and address of the Contractor) as Principal, hereinafter called Principal, and WEST BEND MUTUAL INSURANCE COMPANY as Surety, hereinafter called Surety, are held and firmly bound unto City of Oshkosh of 215 Church Ave. Oshkosh, WI 54903-1130 (Name and address of the Owner) as Obligee, hereinafter called Owner, in the amount of Sixty -Three Thousand Three Hundred and Eighty -Seven Dollars and Fifty Cents Dollars ($ 63.387.50 for the payment whereof Contractor and Surety bind themselves, their heirs, executors, administrators, successors and assigns, jointly and severally, firmly by these presents. WHEREAS, Contractor has by written agreement dated 11/22/2024 entered into a contract with Owner for Installation of epoxy floor coating: various city buildings in accordance with drawings and specifications prepared by (Name of Architect or Engineer) which contract is by reference made a part hereof, and is hereinafter referred to as the Contract. NOW, THEREFORE, THE CONDITION OF THIS OBLIGATION is such that, if Contractor shall promptly and faithfully perform said contract, then this obligation shall be null and void; otherwise it shall remain in full force and effect. The Surety hereby waives notice of any alteration or extension of time made by the Owner. Whenever Contractor shall be, and declared by Owner to be in default under the Contract, the Owner having performed Owner's Obligations thereunder, the Surety may promptly remedy the default, or shall promptly 1. Complete the Contract in accordance with its terms and conditions, or Obtain a bid or bids for completing the Contract in accordance with its terms and conditions, and upon determination by Surety of the lowest responsible bidder, or, if the Owner elects, upon determination by the Owner and the Surety jointly of the lowest responsible bidder, arrange for a contract between such bidder and Owner, and make available as Work progresses (even though there should be a default or a succession of defaults under the contract or contract of completion arranged under this paragraph) sufficient funds to pay the cost of completion less the balance of the contract price; but not exceeding, including other costs and damages for which the surety may be liable hereunder, the amount set forth in the first paragraph hereof. The term "balance of the contract price", as used in this paragraph, shall mean the total amount payable by Owner to Contractor under the Contract and any amendments thereto, less the amount properly paid by Owner to Contractor. PROVIDED, FURTHER, that it is expressly agreed that the BOND shall be increased automatically and immediately, without the need for separate amendments hereto, upon amendment to the Contract that does not increase the contract price more than ten (10) percent, so as to bind the PRINCIPAL and the SURETY to the full and faithful performance of the CONTRACT as so amended. The term "Amendment", wherever used in this BOND, and whether referring to this BOND, the Contract or the Loan Documents shall include any alteration, addition, extension, or modification of any character whatsoever. NB 0012 04 22 Page 1 of 2 1900 S 18th Avenue I West Bend, WI 53095 1 Phone: (800) 236-5010 1 Fax: (877) 674-2663 1 www.thesilverlining.com Any suit under this bond must be instituted before the expiration of one (1) year from the date on which final payment under the contract falls due. No right of action shall accrue on this bond to or for the use of any person or corporation other than the Owner named herein of the heirs, executors, administrators or successors of the Owner. Signed and Sealed this 12 day of December 20 2_4 PrincipalIdkA& Black Diam By: (SEAL) Witness: �-'� �i`� Name yped: Andrew Nickelatti !President Title Witness: D ,1..,- \,(\, )JJJ\-� Surety: West Berld Mutual rance Company B '_--' (SEAL) Name Type THOMAS PUPETE , Attorney -in -Fact Title MICHIGAN ONLY: This policy is exempt from the filing requirements of Section 2236 of the Insurance Code of 1956, 1956 PA 218 and MCL 500.2236. NIB 00120422 Page 2of2 1900 S 18th Avenue I West Bend, WI 53562 1 Phone: (800) 236-5010 1 Fax: (877) 674-2663 1 www.thesilverlining.com C WEST BEND Bond Number 2631006 Labor and Material Payment Bond KNOW ALL MEN BY THESE PRESENTS: That Black Diamond WI LLC PO Box 7263, Appleton, WI 54912-7263 (Name and address of the Contractor) as Principal, hereinafter called Principal, and WEST BEND MUTUAL INSURANCE COMPANY as Surety, hereinafter called Surety, are held and firmly bound unto City of Oshkosh of 215 Church Ave. Oshkosh. WI 54903-1130 (Name and address of the Owner) as Obligee, hereinafter called Owner, for the use and benefit of claimants as hereinbelow defined, in the amount of Sixty -Three Thousand Three Hundred and Eighty -Seven Dollars and Fifty Cents Dollars ($ 63,387.50 ) (Insert a sum equal to at least one-half of the contract price) for the payment whereof Principal and Surety bind themselves, their heirs, executors, administrators, successors and assigns, jointly and severally, firmly by these presents. WHEREAS, Principal has by written agreement dated 11/22/2024 entered into a contract with Owner for Installation of epoxy floor coating: various city buildings in accordance with drawings and specifications prepared by (Name of Architect/Engineer) which contract is by reference made a part hereof, and is hereinafter referred to as the Contract. NOW, THEREFORE, THE CONDITION OF THIS OBLIGATION is such that if the Principal shall promptly make payment to all claimants as hereinafter defined, for all labor and material used or reasonably required for use in the performance of the Contract, then this obligation shall be void; otherwise it shall remain in full force and effect, subject, however, to the conditions outlined on the reverse side of this bond: Signed and Sealed this 12 day of December 20 24 Principal: Black Di o I LC B - (SEAL) Witness: Na Typed: Andrew Nickelatti President Title Surety: West Ben I Mut urance Company (SEAL,,, Witness: Name Typed: THOM 11PE , Attorney -In -Fact Title MICHIGAN ONLY: This policy is exempt from the filing requirements of Section 2236 of the Insurance Code of 1956, 1956 PA 218 and MCL 500.2236. NB 0011 04 22 Page 1 of 2 1900 S 18th Avenue I West Bend, WI 53095 1 Phone: (800) 236-5010 1 Fax: (877) 674-2663 1 www.thesilverlining.com CONDITIONS 1. A claimant is defined as one having a direct contract with the Principal or with a Subcontractor of the Principal for labor, material, or both, used or reasonably required for use in the performance of the Contract, labor and material being construed to include that part of water, gas, power, light, heat, oil, gasoline, telephone service or rental of equipment directly applicable to the Contract. 2. The above named Principal and Surety hereby jointly and severally agree with the Owner that every claimant as herein defined, who has not been paid in full before the expiration of a period of ninety (90) days after the date on which the last of such claimant's work or labor was done or performed, materials were furnished by such claimant may sue on this bond for the use of such claimant, prosecute the suit to final judgement for such sum or sums as may be justly due claimant, and have execution thereon. The Owner shall not be liable for the payment of any costs or expenses of any such suit. 3. No suit or action shall be commenced hereunder by any claimant. a. Unless claimant, other than one having a direct contract with the Principal, shall have given written notice to any two of the following: The Principal, the Owner, or the Surety above named, within ninety (90) days after such claimant did or performed the last of the work or labor, or furnished the last of the materials for which said claim is made, stating with substantial accuracy the amount claimed and the name of the party to whom the materials were furnished, or for whom the work or labor was done or performed. Such notice shall be served by mailing the same by registered mail or certified mail, postage prepaid, in an envelope addressed to the Principal, Owner or Surety, at any place where an office is regularly maintained for the transaction of business, or served in any manner in which legal process may be served in the state in which the aforesaid project is located, save that such service need not be made by a public officer. b. After the expiration of one (1) year following the date on which Principal released work on said Contract, it being understood, however, that if any limitation embodied in this bond is prohibited by any law controlling the construction hereof such limitation shall be deemed to be amended so as to be equal to the minimum period of limitation permitted by such law. c. Other than in a state court of competent jurisdiction in and for the county or other political subdivision of the state in which the project, or any part thereof, is situated, or in the United States District Court for the district in which the project, or any part thereof, is situated, and not elsewhere. 4. The amount of this bond shall be reduced by and to the extent of any payment or payments made in good faith hereunder, inclusive of the payment by Surety of mechanics' liens which may be filed of record against said improvement, whether or not claim for the amount of such lien be presented under and against this bond. NIS 0011 04 22 Page 2 of 2 1900 S 18th Avenue I West Bend, WI 53095 1 Phone: (800) 236-5010 1 Fax: (877) 674-2663 1 www.thesilverlining.com WEST BENDS POWER OF ATTORNEY Bond No. 2631006 Know all men by these Presents, that West Bend Insurance Company (formerly known as West Bend Mutual Insurance Company prior to 1/1/2024), a corporation having its principal office in the City of West Bend, Wisconsin does make, constitute and appoint: THOMAS PUPETER lawful Attorney(s)-in-fact, to make, execute, seal and deliver for and on its behalf as surety and as its act and deed any and all bonds, undertakings and contracts of suretyship, provided that no bond or undertaking or contract of suretyship executed under this authority shall exceed in amount the sum of: Thirty Million Dollars ($30,000,000) This Power of Attorney is granted and is signed and sealed by facsimile under and by the authority of the following Resolution adopted by the Board of Directors of West Bend Insurance Company by unanimous consent resolution effective the 1st day of January 2024. Appointment of Attorney -In -Fact. The president or any vice president, or any other officer of West Bend Insurance Company may appoint by written certificate Attorneys-ln-Fact to act on behalf of the company in the execution of and attesting of bonds and undertakings and other written obligatory instruments of like nature. The signature of any officer authorized hereby and the corporate seal may be affixed by facsimile to any such power of attorney or to any certificate relating therefore and any such power of attorney or certificate bearing such facsimile signatures or facsimile seal shall be valid and binding upon the company, and any such power so executed and certified by facsimile signatures and facsimile seal shall be valid and binding upon the company in the future with respect to any bond or undertaking or other writing obligatory in nature to which it is attached. Any such appointment may be revoked, for cause, or without cause, by any said officer at any time. Any reference to West Bend Mutual Insurance Company in any Bond and all continuations thereof shall be considered a reference to West Bend Insurance Company. In witness whereof, West Bend Insurance Company has caused these presents to be signed by its president undersigned and its corporate seal to be hereto duly attested by its secretary this 1st day of January 2024. �41/L15 tiUiY C• oPPO�Fc� Ile Attest Christo her C. Zryygart =m Robert J. Jacques - ~ '$ SEA, h; v = President Secretary N ;9� ,; r State of Wisconsin County of Washington On the 1st day of January 2024, before me personally came Robert Jacques, to me known being by duly sworn, did depose and say that he is the President of West Bend Insurance Company, the corporation described in and which executed the above instrument; that he knows the seal of the said corporation; that the seal affixed to said instrument is such corporate seal; that is was so affixed by order of the board of directors of said corporation and that he signed his name thereto by like order. ` `'BEN,,It,, �NOTAIq G�'," UBLIG Dead , orporate Attorney �5 OpW18�0Notary Public, Washington Co., WI My Commission is Permanent The undersigned, duly elected to the office stated below, now the incumbent in West Bend Insurance Company, a Wisconsin corporation authorized to make this certificate, Do Hereby Certify that the foregoing attached Power of Attorney remains in full force effect and has not been revoked and that the Resolution of the Board of Directors, set forth in the Power of Attorney is now in force. Signed and sealed at West Bend, Wisconsin this 12th day of December , 2024 Christoplier C. Zwy a 'n�7y�y"TOTON �'Oy,=: Secretary 1900 S 18th Avenue I West Bend, WI 53095 1 Phone: (800) 236-5010 1 Fax: (877) 674-2663 1 www.thesilverlining.com