Loading...
HomeMy WebLinkAbout0103808 B(~ CITY OF OSHKOSH OSHKOSH BUILDING PERMIT - APPLICATION AND RECORD ON THE WATER Job Address 2217 MOUNT VERNON ST Owner DEL TRITT CONST LLC Designer Contractor DEL TRITT CONSTRUCTION Category 110 - New Single Family No 103808 Create Date 08/27/2003 Plan El-121-0803R Type 10 Building ~ Sign ~ Canopy ~ Fence ~ Raze Zoning R-1 Class of Const: 8 Unfinished/Basement 1072 Sq. Ft. Rooms 5 Height 17 Ft. Finished/Living 1072 Sq. Ft. Bedrooms 2 Stories 1 Garage 442 Sq. Ft. Baths 1 Foundation O Poured Concrete ~ Floating Slab ~ Pier ~ Other ~ Concrete Block ~ Post ~ Treated Wood Occupancy Permit Required Flood Plain No Height Permit Park Dedication Required # Dwelling Units 1 # Structures Size Irrg ~J Projection Canopies Signs Not Required 1 Use/Nature NSFR/ New single family 1 story with 2 car attached garage. 6' x 12' covered porch. Driveway will be 20' wide at the front property line. of Work HVAC Contractor MCM AIR INC Plumbing Contractor RASMUSSEN PLUMBING Electric Contractor CUMINGS ELECTRIC Fees: Valuation $78,000.00 Plan Approval $75.00 Permit Fee Paid $314.00 Park Dedication $100.00 Issued By: Date 08/28/2003 Final/O.P. 00/00/0000 Permit Voided In the performance of this work I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Date Agent/Owner Address 6228 COUNTY RD N PICKETT WI 54964 - 9533 Telephone Number 589-4209 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. OSHKOSH ON THE WATER Name DEL TRITT CONST LLC GRADE STAKE FORM Address 2217 MOUNT VERNON ST Lot Block Subdivision Zone Street Number Lot Dimensions Building Grade Elevation Stakes Set At Site 08/27/2003 Set By Grade Stake Number 7023 Create Date 08/27/2003 D.W.G. Ward Sidewalk Existing Department of Public Works I, the undersigned, owner or agent of the above described property agree to have the grade established before excavation has commenced. OSHKOSH ON THE WATER .lob Address 2217 MOUNT VERNON ST Name DEL TRITT CONST LLC Address 6228 CO RD N Subdivision Building Permit Number 0103808 Number of Dwelling Units 1 Fee Required $100.00 PARKLAND DEDICATION FEE COLLECTION RECORD Date 08/28/2003 PICKETT WI 54964 Lot Number of Structures Fee Paid Owner's Signature Inspector's Signature Date Date Wisconsin Department of Industry, WISCONSIN UNIFORM Application No. Labor and Human Relations Safety and Buildings Division BUILDING PERMIT o1o38o8 P.O. Box 2509 APPLICATION Parcel No. Madison, WI 53701-2509 Wisconsin Statues 101.63, 101.73 [] Constr [] HVAC [] Elec [] Plbg [] Erosion [] Other: Owner's Name Mailing Address Telephone No. DEL TRITT CONST LLC 6228 CO RD N PICKETT WI 54964 - 0000 Contractor: L~J Con~J Elec~J HVAC ~J Plbg Lic/Cert # Mailing Address Telephone No. DEL TRITT CONSTRUCTION 665731 6228 COUNTY RD N PICKETT WI 54964 - 9533 589-4209 Contractor: ~J Con ~J Elec~J HVAC~J Plbg Lic/Cert # Mailing Address Telephone No. CUMINGS ELECTRIC 170792 PO BOX749 1414 COUNTY RD JJ NEENAH WI 54957 - 749 231-5946 Contractor: ~J Con ~J Elec~J HVAC [] Plbg Lic/Cert # Mailing Address Telephone No. MCM AIR INC 4264 6122 COUNTY ROAD M WINNECONNfW 54986 - 9780 (920) 582-4402 Contractor: ~J Con [] Elec [] HVAC [] Plbg bio/Cart # Mailing Address Telephone No. RASMUSSEN PLUMBING 1914 GREENBRIAR TRL OSHKOSH WI 54904 - 8887 920-233-6747 I Lot Area Sq. ft. 1/4, 1/4, Section , T N, R E(or)W Building Address Subdivision Name Lot No. Block No. 2217 MOUNT VERNON ST Zoning District(s) lZoning Permit No. Front Rear Left Right J __Setbacks ft ......... _f_t_: ft ft , .............................. L~J New [] Repair [] Single Family Entrance Panel L~J Forced Air Furnace Fuel Nat. L.P. Oil Elec. Solid Sola [] Alteration [] Raze [] Two Family Size: 100 amp [] Radiant Baseboard or Panel Gas , [] Addition [] Garage Service: [] Heat Pump Space Htg [] [] [] [] [] [] [] Move [] Other (print): [] Overhead [] Boiler Water Htg [] [] [] [] [] [] [] Other: [] Underground [] Central Air Conditioning * ~J Dwelling unit will have 3 kilowatt or ] 8~l~,lS~ ~Y~E ~ f~OND~ION [] Other = more installed electric space heating equip. [] Site Constructed · Concrete - Infiltration control option is: [] Full sealing Unfinished [] Manufactured · Masonry Sewer of joints. [] Blower door test. [] Exterior Basement 1072 Sq. ft. S 8~IES · Treated Wood [] Municipal air infiltration barrier. Living Area 1072 Sq. ft. [] 1-Story · Other [] Septic [] 2-Story Permit No. Envelope 19830 BTU/HR Garage 442 Sq. ft. [] Other [] Seasonal Infiltration 13121 BTU/HR [] Permanent [] Municipal Utility [] Plus Basement [] Other [] Private On-Site Well $93,000.00 The applicant agrees to comply with all applicable codes, statues and ordinances and with the conditions of this permit, understands that the issuance of the permit creates no legal liability, express or implied, on the Department or municipality; and certifies that all the above information is accurate. APPLICANT'S SIGNATURE DATE SIGNED This permit is issued pursuant to the following conditions. Failure to comply may result in suspension or APPROVAL CONDITIONS revocation of this permit or other penalty SEE "STANDARD CONDITIONS OF APPROVAL" SHEET [] Town [] Village [] City [] County ~J State of: Municipality Number of Dwelling Location: ~ll~BIB~lOl~,i City Of Oshkosh 7 0 - 2 6 6 ~IS UN!EORIVl ~ERMI~ ~ERIVlI~ iSSUED B~ ~SS=E= SE~ Ne ~ Construction Plan Review $75.00 _ HVAC Name JOHN ZARATE Inspection Electrical Wis. Permit Seal $30.00 Plumbing Date $/27/03 Other [] Erosion Total $105.00 · 292173 Cert. No. 70330 SBD-5823 (R. 07/92) OSHKOSH ON THE WATER Job Address 2217 MOUNT VERNON ST CITY OF OSHKOSH BUILDING PERMIT - APPLICATION AND RECORD Owner DELTRITT CONST LLC No 103808 Create Date 08/27/2003 Designer Contractor DEL TRITT CONSTRUCTION Category 110 - New Single Family Plan E1-121-0803R Type · Building O Sign (~) Canopy (~ Fence (~) Raze Zoning R-1 Class of Const: 8 Size Irrg Unfinished/Basement 1072 Sq. Ft. Rooms 5 Height 17 Ft. [] Projection Finished/Living 1072 Sq. Ft. Bedrooms 2 Stories I Canopies Garage 442 Sq. Ft. Baths 1 Signs Foundation · Poured Concrete (~ Floating Slab O Pier (~) Other (~ Concrete Block (~) Post (~ Treated Wood Occupancy Permit Required Flood Plain No Height Permit Not Required Park Dedication Required # Dwelling Units 1 # Structures 1 Use/Nature NSFR/ New single family 1 story with 2 car attached garage. 6' x 12' covered porch. Driveway will be 20' wide at the front property line. of Work HVAC Contractor Electric Contractor Fees: Valuation Issued By: ~ MCM AIR INC CUMINGS ELECTRIC $76,000.00 Plan Approval $75.00 Permit Fee Paid [] Permit Voided Plumbing Contractor RASMUSSEN PLUMBING $314.00 Park Dedication $100.00 Date 08/28/2003 Final/O.P. 00/00/0000 In the performance of this work I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in thi,sd~"~t application within an easement, the City strongly urges the permit applicant to contact the easement holder(s,} ~nd ~o ~ecu/e any efore star~ing such activity. Signatur'~.(/J~¢¢~¢~'~',~ Date ~:~--/~ Agent/Owner Address 6228 COUNTY RD N PICKETT WI 54964 - 9533 Telephone Number 589-4209 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. OSHKOSH ON THE WATER Name DELTRITT CONST LLC GRADE STAKE FORM Address 2217 MOUNT VERNON ST Lot Block Subdivision Zone Street Number Lot Dimensions Building Grade Elevation Stakes Set At Site 08/27/2003 Set By Grade Stake Number 7023 Create Date 08/27/2003 Ward D.W.G. Sidewalk Existing Department of Public Works Ii~at~oUnJmereSnicg~;!, owner or agent of the above described property agree to.ha~'7~:te e,~blished before~excavation Wisconsin Department of Industry, Labor and Human Relations Safety and Buildings Division P.O. Box 2509 Madison, WI 53701-2509 Wisconsin Statues 101.63, 101.73 Owner's Name DEL TRITT CONST LLC Contractor:~ Con[~ DEL TRITT CONSTRUCTION Contractor: CUMINGS ELECTRIC Contractor: C Contractor:'~ Con :~,SMUSSEN PLUMBING Building Address 2217 MOUNT VERNON ST WISCONSIN UNIFORM JApplication No. BUILDING PERMIT 1 0103808 APPLICATION Parcel No. [] Constr [] HVAC [] Elec [] Plbg [] Erosion [] Other: Mailing Address Telephone No. 6228 CO RD N PICKETT WI 54964 - 0000 Lic/Cert # Mailing Addrass Telephone NO. 665731 6228 COUNTY RD N PICKETT WI 54964 - 9533 589-4209 Lic/Cert # i Mailing Address Telephone No. PO BOX749 1414 COUNTY RD JJ NEENAH WI 54957 - 749 231-5946 Mailing Address Telephone No. 3122 COUNTY ROAD ~M WINNECONN~W154986 - 9780 (920) 582-4402 Mailing Address Telephone No. 1914GREENBRIARTRL OSHKOSH WI54904 -8887 920-233-6747 Lot Area 1/4, 1/4,Section ,T N,R E(or)W Subdivision Name Lot NO. Block No. Zoning District(s) Zoning Permit No. Front Rear Left Right New [] Repair Forced Air Fumace [] Alteration [] Raze -~ Radiant Baseboard or Panel ~ Heat Pump [] Addition [] Move ~ Boiler [] Other: Central Air Conditioning Single Family Entrance Panel Two Family Size: Garage Service: Other (pdnt): [] Overhead ~ Underground Dwelling unit will have 3 kilowatt or more installed electdc space heating equip [] Site Constmc'[ed Concrete Infiltration control option is: [] Full sealing Unfinished [] Manufactured Masonry Sewer ofjointa. [] Blower door test. [] Exterior Basement 1072 Sq. ff. Treated Wood [] Municipal air infiltration barrier. Living Area 1072 Sq. ft. 1-Story Other [] 2-Stary [] Septic Garage 442 Sq. ft. [] Other ~ Seasonal Permit No. !InfiltrationEnVel°pe 1312119830 BTU/HRBTU/HR Permanent Other [] Plus Basement [] Municipal Utility [] Private On-Site Well $93,000.00 The applicant agrees to comply with ~ codes, statues and ordinances and with the conditions of this permit, understands that the issuance of the permit creates no legal liability, e and certifies that all the above information is accurate. APPLICANT'S SIGNATURE DATE SIGNED 06:> ;"~::;2- ~ 3 APPROVAL CONDITIONS ollowing conditions. Failure to comply may result in suspension or revocation of this permit or other penalty SEE "STANDARD CONDITIONS OF APPROVAL" SHEET Town [] Village [] City [] County State of: Municipality Number of Dwelling Location: CityOf Oshkosh 7 0 2 6 6 Plan Review $75.00 Construction HVAC Name JOHN ZARATE inspection Electrical Wis. Permit Seal $30.00 Plumbing Date 8/27/03 Other Erosion Total $105.00 292173 Cert. No. 70330 SBD-5823 (R. 07/92) OSHKOSH ON THE WATER ,Job Address 2217 MOUNT VERNON ST Name DEL TRITT CONST LLC Address 6228 CO RD N Subdivision Building Permit Number 0103808 Number of Dwelling Units Fee Required Owner's Signature Inspector's Signature PARKLAND DEDICATION FEE COLLECTION RECORD PICKETT Lot Date 08/28/2003 WI 54964 1 $100.00 Fee Paid Number of Structures Date CITY OF OSHKOSH STANDARD CONDITIONS OF XPPROVXi~ Project Address 2Tl~ ~OU~)~ 1/E~O~ Permit # Please r ad the following mformatton and s~gn at the bottom to acknowledge that you have read and agree to comply with these conditions. All habitable rooms must be provided with 8% light and 3.5% ventilation. Bedrooms located on the second floor or below ground level must be provided with egress windows in addition to the light and ventilation requirements. Basement windows ar~ h]~i3 ............... required to have window well areas in accordance with ILHR 21.03. Garage spaces shall be separated from ~e dwellin~ unit ii/id~6~lanCe~v3ifi-iL~ The door and frame assembly between the dwelling unit and an attached garage shall be labeled by an independent testing agency as having a minimum fire-resistive rating of 20 minutes. All drywall joints are required to be taped/~ealed unless the joints ar~ fitted so that the gap is no more than a dimes thickness (1/20-inch) and backed by solid wood or drywall with the joints staggered. All penetrations in exterior walls must be sealed prior to the insulation inspection. This includes holes in the top and bottom i31ates, gap~ aroUnd heating ducts, and holes in th~ ........... return air spaces. Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke detectors are required to be hardwired and interconnected. Hydromassage tubs are required to have an access panel to motor. The access panel mus~ be accessible without removing the finish of the house. All overframing must be designed by th~ tm~s rnhnufacturer, according to Standards set by the truss plate institute, or structural calculations must be provided prior to the rough building inspection. 7. Truss plans must be submitted and approved prior to framing the roof. Truss plans including the tress layout must be provided on site at the rough building inspection. In addition to the tress plans, microlam calculations must be provided on site at the rough building inspection for all microlams with point load§ on them. Calculations must be provided for all cantilevered floors with point loads. Floor trusses and TJI's must be designed for the cantilevered areas. 10. 11. 12. 13. 14. 15. 16. The property owner and applicant is responsible for compliance with.ILHR 21.125 (Erosion Control). When installing access drives, a minimum of 2"-3" diameter s!on~ ts required in addition to a minimum of 6" depth. 30'-50' length, and 14'-20' width. Erosion control measures rn~s_~.b~.~m~.~gtajn.~4.~ug~l.~_~e [a~wn i~. eF~lis_~_ed~_ ........... All storm sewer inlets must be protected with approved erosion control devices. Tracking (i.e. sediment) must be removed from the s~e~e_t.gt~tl~gO. 9_feagh__w_o_r~.day. Repair any siltation or erosion damage to adjoining surfaces and drainageways resulting from land development or disturbing activities. The building placard must be posted on site at all times. On~_e the rough flaming is up the placard must he posted on the patio door or on a kitchen window. If the placard is not present at any inspection, stop work orders will be posted. Additional placards can be obtained through our department if the cards are misplaced. All mechanicals must be roughed in prior to requesting the rough building inspection. If on the inspection the mechanicals are not roughed in, the inspection will fail and a $100 reqnspection fee will be charged. Attached is a copy of the final inspection checklist. Atthe final inspection all items on this list must be completed to avoid the $100 re-inspection fee per inspection. When requesting final inspections please note that a minimum of 2 days notice is needed from the time the inspection is ready. Furniture is only allowed to be placed in the center of the garage floor and a minimum of a 3' pathway must be provided around the walls of the garage. At the final inspection no furniture or personal belongings are allowed in the house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in place due to the electrical inspector needing to look at the power servmg the appliances. A 6' stepladder must be on site at the final inspection to provide access m the attic. The building placard must remain on the patio door or on a kitchen window_~untjl. occupancy is approved. Occupancy is not allowed prior to the placard having all of the final inspection approved stickers on the backside. If o_qgupancy occurs prior to the inspections being approved daily citations will be issued ~vith n9 .fu~r~th~r~c_e_h.ei~ng given. 17. All site grading must be done in accordance with the approved drainage plan on file in the public works offi:~r.ce-3rd-fl~ . ~