HomeMy WebLinkAboutUW Oshkosh Kitchen Elevators DIS-032409502 Wisconsin Department of Safety and Professional Services Phone: 608-266-2112 Division of Industry Services Web: http://dsps.wi.gov 4822 Madison Yards Way Email: dsps@wisconsin.gov PO Box 7302 Madison, WI 53707 Tony Evers, Governor Dan Hereth, Secretary 4/4/2024 CONDITIONAL APPROVAL PLAN APPROVAL EXPIRES: 04/04/2025 CODE APPLIES: 03/01/2024 MUNICIPALITY: CITY OF OSHKOSH WINNEBAGO COUNTY SITE: 44OP-369013 UW KITCHEN ELEVATORS ALT 800 ALGOMA BLVD OSHKOSH, WI 54901 FOR: 800 ALGOMA BLVD Building Name: 44OP-369013 UW Oshkosh Kitchen Elevator ALT- Fire Alarm Object Type: Fire Alarm Building Review Type: Alteration Total Protected Area (Sq Ft): 4,231 Occupancies: B - Business, Fire Alarm Installation: Complete Fire Alarm System: Automatic Detection Supervising Station: Central Station SITE REQUIREMENTS • Contact both the State Inspector and the local municipality PRIOR to the start of construction. • A full-size copy of the approved plans, specifications and this letter shall be on -site during construction and open to inspection by authorized representatives of the Department, which may include local inspectors. If plan index sheets were submitted in lieu of additional full plan sets, a copy of this approval letter and index sheet shall be attached to plans that correspond with the copy on file with the Department. If these plans were submitted in an electronic form, the designer is responsible to download, print, and bind the full-size set of plans along with our approval letter. A Department electronic stamp and signature shall be on the plans which are used at the job site for construction. The following conditions shall be met during construction or installation and prior to occupancy or use: KEY ITEM(S): This conditional approval is only for the altered portions and systems of the building shown on the plans. All other areas of the building have not been reviewed and are not a part of this approval. • IBC 907.3 - Provide automatic fire detectors connected to the fire alarm control panel which perform fire safety functions. Automatic fire-extinguishing systems provided in a commercial building shall be connected to the building fire alarm system. • IBC 907.6 - Provide a fire alarm system installed in accordance with NFPA 72. Identification Numbers Plan Review No.: CB-042400173-PRFA Application No.: DIS-032409502 Site ID No.: SIT-127497 Please refer to all identification numbers in each correspondence with the Department. NATHAN STOPPENBACH EDGE ELECTRIC 1265 E WISCONSIN AVE. STE. A PEWAUKEE, WISCONSIN 53072 • NFPA 72 (2013) 10.3.3 All devices and appliances that receive their power from the initiating device circuit or signaling line circuit of a control unit shall be listed for use with the control unit. Ensure new equipment and all existing devices are compatible with each other. • SPS 361.31 - These plans were conditionally approved electronically. The designer is responsible to download the plans, print out complete sets and permanently bind each set of the conditionally approved electronic plans, along with a complete bound set of specifications, as submitted to the Dept., for reference in the field. Plans for field reference shall be the same size and scale as originally submitted to the Dept. per SPS 361.31(2)(a), and per SPS 361.31(2)(d) shall be clear and legible. A complete bound conditionally approved set of plans and set of specifications shall be made available to a Dept. representative on-site upon request. There shall be an electronic stamp and signature on the index page of the conditionally approved plans by the Dept. representative that conditionally approved the plans, as well as the professional of the project if the building is over 50,000 cubic ft. Additionally, a copy of the conditional approval letter issued by the Dept. shall be permanently attached to each of the conditionally approved plan sets. REMINDERS: • IBC 907.7 - Acceptance tests and completion - Upon completion of the installation, the fire alarm system and all fire alarm components shall be tested in accordance with NFPA 72. A record of completion in accordance with NFPA 72 verifying that the system has been installed and tested in accordance with the approved plans and specifications shall be kept for the life of the system and be available to an authority having jurisdiction. • SPS 361.33 - Where plan approval is required by this code, one set of plans, inclusive of a copy of all specifications, bearing the stamp of conditional approval and a copy of the specifications shall be kept at the building site. The plans and specifications shall be open to inspection by the department or its authorized representative. • Municipal Building Official, please forward a copy of this letter to the official in charge of conducting fire department inspections in your municipality. The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements. Only those object types listed above have been approved; other submittals such as plumbing and those listed above under REQUIRED SUBMITTAL(S), may also be required. All permits required by the state, or the local municipality shall be obtained prior to commencement of construction/installation/operation. You are responsible for complying with state and federal laws concerning construction n ear or on wetlands, lakes, and streams. This plan has not been reviewed for compliance with fire code requirements, including those for fire lanes and fire protectio n water supply, so contact the local fire department for further information. In granting this approval, the Division of Industry Services reserves the right to require changes or additions, should condi tions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the desi gner of the responsibility for designing a safe building, structure, or component. The Division does not take responsibility for the des ign or construction of the reviewed items. Per s. SPS 361.40(4), projects for buildings of over 50,000 cubic feet total volume shall have supervising professionals who file compliance statements with this agency and the local code officials prior to occupancy of the project. Compliance statements shall be filed online at https://esla.wi.gov/PortalCommunityLogin. Inquiries concerning this correspondence may be made to me at the contact information listed below, or at the address on this letterhead. Sincerely, Alex Payne Division of Industry Services Phone: 608-261-0354 Email: alex.payne@wisconsin.gov cc: BRIAN NOE, DIS INSPECTOR, 920-420-4796, BRIAN.NOE@WISCONSIN.GOV DIANE BARTLETT, MUNICIPAL CLERK, 920-236-5094, DBARTLETT@CI.OSHKOSH.WI.US CAMDEN JERUP, SIEMENS INDUSTRY