HomeMy WebLinkAboutNicolet Lumber Oshkosh Apt. DIS-122351855 Wisconsin Department of Safety and Professional Services Phone: 608-266-2112 Division of Industry Services Web: http://dsps.wi.gov 4822 Madison Yards Way Email: dsps@wisconsin.gov PO Box 7302 Madison, WI 53707 Tony Evers, Governor Dan Hereth, Secretary 1/12/2024 CONDITIONAL APPROVAL PLAN APPROVAL EXPIRES: 01/12/2026 CODE APPLIES: 12/13/2023 MUNICIPALITY: CITY OF OSHKOSH WINNEBAGO COUNTY SITE: NICOLET LUMBER OSHKOSH APARTMENTS OREGOON ST OSHKOSH, WI 54902 FOR: OREGOON ST Building Name: RIPPLE ESTATES BLDG 6- Fire Suppression Object Type: Fire Suppression Building Review Type: New Total Protected Area (Sq Ft): 19,440 Fire Suppression Installation: Complete Occupancies: R-2 - Apartments, Dormitories, Monasteries, etc., None Fire Sprinkler Type: Wet Building Name: RIPPLE ESTATES BLDG 1- Fire Suppression Object Type: Fire Suppression Building Review Type: New Total Protected Area (Sq Ft): 19,440 Fire Suppression Installation: Complete Occupancies: R-2 - Apartments, Dormitories, Monasteries, etc., None Fire Sprinkler Type: Wet Building Name: RIPPLE ESTATES BLDG 2- Fire Suppression Object Type: Fire Suppression Building Review Type: New Total Protected Area (Sq Ft): 19,440 Fire Suppression Installation: Complete Occupancies: R-2 - Apartments, Dormitories, Monasteries, etc., None Fire Sprinkler Type: Wet Building Name: RIPPLE ESTATES BLDG 3- Fire Suppression Object Type: Fire Suppression Building Review Type: New Total Protected Area (Sq Ft): 19,440 Fire Suppression Installation: Complete Occupancies: R-2 - Apartments, Dormitories, Monasteries, etc., None Fire Sprinkler Type: Wet Identification Numbers Plan Review No.: CB-012400028-PRFS Application No.: DIS-122351855 Site ID No.: SIT-124913 Please refer to all identification numbers in each correspondence with the Department. JAKE BEHRINGER BADGERLAND FIRE PROTECTION 5668 EXECUTIVE CIRCLE LITTLE SAUMICO, WISCONSIN 54141 Building Name: RIPPLE ESTATES BLDG 4- Fire Suppression Object Type: Fire Suppression Building Review Type: New Total Protected Area (Sq Ft): 19,440 Fire Suppression Installation: Complete Occupancies: R-2 - Apartments, Dormitories, Monasteries, etc., None Fire Sprinkler Type: Wet Building Name: RIPPLE ESTATES BLDG 5- Fire Suppression Object Type: Fire Suppression Building Review Type: New Total Protected Area (Sq Ft): 19,440 Fire Suppression Installation: Complete Occupancies: R-2 - Apartments, Dormitories, Monasteries, etc., None Fire Sprinkler Type: Wet Building Name: RIPPLE ESTATES BLDG 7- Fire Suppression Object Type: Fire Suppression Building Review Type: New Total Protected Area (Sq Ft): 19,440 Fire Suppression Installation: Complete Occupancies: R-2 - Apartments, Dormitories, Monasteries, etc., None Fire Sprinkler Type: Wet Building Name: RIPPLE ESTATES BLDG 8- Fire Suppression Object Type: Fire Suppression Building Review Type: New Total Protected Area (Sq Ft): 19,440 Fire Suppression Installation: Complete Occupancies: R-2 - Apartments, Dormitories, Monasteries, etc., None Fire Sprinkler Type: Wet SITE REQUIREMENTS  Contact both the State Inspector and the local municipality PRIOR to the start of construction.  A full size copy of the approved plans, specifications and this letter shall be on-site during construction and open to inspection by authorized representatives of the Department, which may include local inspectors. If plan index sheets were submitted in lieu of additional full plan sets, a copy of this approval letter and index sheet shall be attached to plans that correspond with the copy on file with the Department. If these plans were submitted in an electronic form, the designer is responsible to download, print, and bind the full size set of plans along with our approval letter. A Department electronic stamp and signature shall be on the plans which are used at the job site for construction. The following conditions shall be met during construction or installation and prior to occupancy or use: KEY ITEM(S):  IBC 903.3.1.2 - Provide an automatic fire sprinkler system installation per NFPA 13R.  NFPA 13R (2013) - 5.2.3.2 When nonmetallic pipe is used in combination systems utilizing steel piping internally coated with corrosion inhibitors and nonmetallic piping, the steel pipe coating shall be investigated for compatibility with the nonmetallic piping by a testing laboratory.  NFPA 13R (2013) - 5.2.3.4 When nonmetallic pipe is used in combination systems utilizing steel pipe, cutting oils and lubricants used for fabrication of the steel piping shall be compatible with the nonmetallic pipe materials.  NFPA 13R (2013) - 5.2.3.5 Fire-stopping materials intended for use on nonmetallic- piping penetrations shall be investigated for compatibility with the nonmetallic pipe materials.  NFPA 13R (2013) - 5.2.12.2.1.1 When nonmetallic fittings are used in combination systems utilizing internally coated steel piping and nonmetallic fittings, the steel pipe shall be investigated for compatibility with the nonmetallic fittings by a testing laboratory. Cutting oils and lubricants used for fabrication of the steel piping shall be compatible with the nonmetallic fitting materials.  NFPA 13R (2013) - 5.2.12.2.1.3 Fire-stopping materials intended for use on nonmetallic fitting penetrations shall be investigated for compatibility with the nonmetallic fitting materials.  NFPA 13R (2013) 6.4.1 Residential Sprinklers That Have Been Listed with Specific Coverage Criteria. Sprinklers shall be installed in accordance with the coverage criteria specified by the listing. Ensure sprinklers do not exceed manufacturer's specifications.  NFPA 13R (2013) 6.4.6.3.4.1 Pendent sprinklers shall be located at least 3 ft (914 mm) from obstructions such as ceiling fans and light fixtures unless the requirements of 6.4.6.3.6 are met. Ensure appropriate installation.  NFPA 13R (2013) - 6.4.6.3.5.1 Sidewall sprinklers shall be located at least 5 ft (1.52 m) from obstructions such as ceiling fans and light fixtures unless the requirements of 6.4.6.3.7 are met. Ensure appropriate installation.  IBC 901.6.1 - Automatic sprinkler systems shall be monitored by an approved supervising station.  IBC 912.2 - The fire department connection shall be installed in an accessible location acceptable to the fire chief. REMINDERS:  SPS 361.31(2)(b) - A copy of this approval letter and index sheet shall be attached to plans that correspond with the copy on file with the Department. Changes to the approved plan must be submitted for review and approval. Failure to properly attach the approval and index page to the plans that match the copy on file with Department may result in enforcement action under ss. 101.02 or 443.13, Statutes.  SPS 361.33 - Where plan approval is required by this code, one set of plans, inclusive of a copy of all specifications, bearing the stamp of conditional approval and a copy of the specifications shall be kept at the building site. The plans and specifications shall be open to inspection by the department or its authorized representative.  Municipal Building Official, please forward a copy of this letter to the official in charge of conducting fire department inspections in your municipality. The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements. Only those object types listed above have been approved; other submittals such as plumbing and those listed above under REQUIRED SUBMITTAL(S), may also be required. All permits required by the state or the local municipality shall be obtained prior to commencement of construction/installation/operation. You are responsible for complying with state and federal laws concerning construction near or on wetlands, lakes, and streams. This plan has not been reviewed for compliance with fire code requirements, including those for fire lanes and fire protection water supply, so contact the local fire department for further information. In granting this approval, the Division of Industry Services reserves the right to require changes or additions, should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. The Division does not take responsibility for the design or construction of the reviewed items. Per s. SPS 361.40(4), projects for buildings of over 50,000 cubic feet total volume shall have supervising professionals who file compliance statements with this agency and the local code officials prior to occupancy of the project. Compliance statements shall be filed online at https://esla.wi.gov/PortalCommunityLogin. Inquiries concerning this correspondence may be made to me at the contact information listed below, or at the address on this letterhead. Sincerely, Joseph Nowicki Fire Protection Plan Reviewer Division of Industry Services Phone: 414-615-9848 Email: joseph.nowicki@wisconsin.gov cc: BRIAN NOE, DIS INSPECTOR, 920-420-4796, BRIAN.NOE@WISCONSIN.GOV DIANE BARTLETT, MUNICIPAL CLERK, 9202365094, DBARTLETT@CI.OSHKOSH.WI.US DENNIS HERMANS, NICOLET LUMBER CO