Loading...
HomeMy WebLinkAboutItem VII PLAN COMMISSION STAFF REPORT SEPTEMBER 19, 2023 ITEM VII: GENERAL DEVELOPMENT PLAN AND SPECIFIC IMPLEMENTATION PLAN REVIEW FOR AN INDUSTRIAL DEVELOPMENT AT 3463 COMPASS WAY GENERAL INFORMATION Owner/Applicant: Lycon, Inc. Action(s) Requested: The petitioner requests General Development and Specific Implementation Plan approval for an industrial development at 3463 Compass Way. Applicable Ordinance Provisions: Planned Development standards are found in Section 30-387 of the Zoning Ordinance. Background Information Property Location and Type: The subject area involving this request consists of a 31.63-acre vacant parcel located along Compass Way/Transit Drive, east of Clairville Road. The subject site as well as the surrounding area is located in the Southwest Industrial Park and consists of vacant land and industrial uses to the south. The 2040 Comprehensive Plan recommends industrial land use for the subject properties as well as the adjoining parcels. Subject Site Existing Land Use Zoning Industrial HI-PD Adjacent Land Use and Zoning Existing Uses Zoning North Vacant HI-PD South Vacant & Industrial HI-PD East Vacant HI-PD West Vacant HI-PD Recognized Neighborhood Organizations N/A Comprehensive Plan Comprehensive Plan Land Use Recommendation Land Use 2040 Land Use Recommendation Industrial Page 1 ITEM VII – GDP SIP – 3463 Compass Way ANALYSIS Use The applicant is proposing to develop the subject property for manufacturing of concrete and associated activities. This will include railroad access and car storage along with trans-load facilities for the receiving, storage, and shipping of various sands and aggregates. Outdoor storage piles will also be located on the site. The site will also include a recycling facility for the separation and recapture of sands and gravels from wet concrete not used at jobsites. The applicant anticipates that the site will initially have up to 5 employees and up to 30 employees when fully developed. The proposed industrial use is permitted in the HI district and the outdoor storage use is a conditional use. Site Design The proposed site will have two driveway accesses from Compass Way/Transit Drive. The plan includes four buildings centrally located on the site. The proposed buildings are a railroad car off-load facility, aggregate storage facility, Red-mix plant, and Re-claim plant. The site also includes an approximately 185,000 sq. ft. outdoor storage area at the southwest portion of the site. Code requires outdoor storage areas to be screened from non-industrialized areas by any Page 2 ITEM VII – GDP SIP – 3463 Compass Way permitted combination of buildings, structures, walls, and solid fencing. Such walls and fencing shall be a minimum of 8 feet in height and shall be designed to completely screen all stored materials from view from non-industrialized areas. As neighboring properties are industrial- zoned, screening will only need to be provided for the public right-of-way. The applicant has provided several evergreen trees and deciduous on the street sides of the outdoor storage area. Staff is recommending that the landscaping between the storage area and street be increased to form a solid row of evergreen trees to fully screen the view of the storage area or provide 8’ tall solid fencing to meet the screening requirement. Required Provided Front Setback (north/east) 30 ft. min. 60.28 ft. Side Setback (south) 20 ft. min. 20 ft. Side Setback (west) 20 ft. min. 23.42 ft. Page 3 ITEM VII – GDP SIP – 3463 Compass Way Parking (site as a whole) 30 spaces 19 spaces Impervious Surface 70% max. 32% +/- Building Height 60 ft. max. 88 ft. The submitted plan is meeting all applicable setback and impervious surface requirements. The plan shows 19 striped parking stalls, where code requires 1 parking stall per employee at the largest work shift. As the applicant has stated that there will be up to 30 employees, an additional 11 parking stalls will need to be striped to meet the parking requirement. The plan shows sufficient paved area to provide these stalls which can be addressed during Site Plan Review. The plan for the Redi-mix Plant building shows an overall height of 88’, where the maximum building height in the HI district is 60’. According to the applicant, the increased height is needed to enclose tall cement silos that would otherwise be exposed. The applicant has noted that they will provide additional stone veneer on the building and increased building foundation plantings to offset the requested Base Standard Modification (BSM) for increased height. Staff is supportive of the request BSM as the increased height for the tower is needed to accommodate the proposed land use. The site is located within an Airport Height Zoning District, limiting building heights to a maximum elevation of 925’. The applicant has stated that Winnebago County has verified that the building is below the maximum elevation. Written verification of this will be required to be submitted as part of the Site Plan Review approval. To offset the requested BSM, Staff is recommending a condition that a minimum of 20% of the Redi- mix Plant building facades be devoted to Class I materials. Signage The applicant’s submittal does not include signage. Any new signage shall meet base code standards allowed in the HI Zone District. Lighting The provided lighting plan is deficient of the code requirement for lighting levels for drive aisles and parking areas of 0.4 fc lighting illumination. The plan shows 28’ tall light poles being utilized, which exceeds the maximum light fixture height of 25’ for the HI district. These items may be addressed during Site Plan Review. Storm Water Management Storm water management plans have been submitted and are under review by the Department of Public Works. Final storm water management plans will be reviewed during the Site Plan Review process. Page 4 ITEM VII – GDP SIP – 3463 Compass Way Landscaping Paved Area, Street Frontage, Foundation and Yard landscaping points are required for the proposed site. Landscape Plan Points Required Points Provided Paved Areas 509 (152.7 tall trees, 203.6 shrubs) 45 (0 tall trees, 15 shrubs) Street Frontage 795 (397.5 medium trees) 2726 (1,276 medium trees) Foundation 246 495 Yard 2,011 323 Total 3,561 3,589 Building Foundation The proposed building foundation landscaping exceeds the point requirement of 20 points per 100 linear feet of building foundation. Paved Area The proposed landscaping plan does not meet the point requirement of 30 landscaping points 10,000 sq. ft. of paved area. The code further specifies 30% of all points will be devoted to tall Page 5 ITEM VII – GDP SIP – 3463 Compass Way trees and 40% will be devoted to shrubs and a tall deciduous/shade tree is required at the ends of all parking rows. These requirements are also not being met. Trees and shrubs will need to be added or reallocated from other areas of the site to meet all of these requirements, and can be addressed during Site Plan Review. Street Frontage Code requires 30 points per 100 feet of street frontage. The landscaping ordinance also specifies that 50% of the required points must be devoted to medium trees. The plan significantly exceeds these point requirements. The applicant may reallocate some of these trees to meet paved area, yard, and screening requirements. Yards Code requires 10 landscaping points per 1,000 sq. ft. of gross floor area. The provided yard landscaping points do not meet the code requirement. However, the applicant may reallocate excess Street Frontage landscaping points to meet this requirement. Building Facades Section 30-244 of the zoning ordinance requires industrial buildings to be clad in Class I, II or III materials. The ordinance also states that for all facades facing a public street shall be composed of at least 15% Class I materials, but may be reduced to 10% of the façade provided that other elements are incorporated into the building and site design such as façade articulation or increased landscaping. Concrete panels (tilt-up/precast) may be used if they are part of a palette of permitted materials or if they incorporate horizontal and vertical articulation including, but not limited to, changes in color or texture. Non-decorative metal panels may be used if enhanced on all elevations with Class I or II materials amounting to more than 15 percent of each façade. The applicant has provided elevations for the buildings, which will be clad in a combination of faux stone veneer, metal panels, and concrete panels. The provided elevations meet the Class I material requirement for facades facing a public street, with the exception of the north elevation of the Re-claim Plant which shows 0% Class I materials. Staff recommends that Class I materials be added to the exterior of this façade to meet the code requirement. Concrete panels are used on all building elevations. Horizontal and vertical articulation will need to be provided on these façade areas to meet industrial building design standards. Non- decorative metal panels are utilized on the Redi-mix Plant and Aggregate Storage Facility buildings. Class I materials have been provided on each of these facades to meet design standards. Building North Elevation South Elevation East Elevation West Elevation Aggregate Storage Facility 28% Class I* 18% Class I 18% Class I 18% Class I Redi-mix Plant 12% Class I* 16% Class I 15% Class I 18% Class I Re-claim Plant 0% Class I* 0% Class I 21% Class I* 0% Class I *Street facing Page 6 ITEM VII – GDP SIP – 3463 Compass Way Aggregate Storage Facility elevations Redi-mix Plant elevations Page 7 ITEM VII – GDP SIP – 3463 Compass Way Re-claim Plant elevations Railroad Car Off-load Facility elevations FINDINGS/RECOMMENDATION/CONDITIONS In its review and recommendation to the Common Council on an application for a Planned Development district, staff recommends the Plan Commission make the following findings based on the criteria established by Chapter 30-387 (C)(6): (a) The proposed Planned Development project is consistent with the overall purpose and intent of this Chapter. (b) The proposed Planned Development project is consistent with the City’s Comprehensive Plan and other area plans. (It is the responsibility of the City to determine such consistency.) (c) The proposed Planned Development project would maintain the desired relationships between land uses, land use densities and intensities, and land use impacts in the environs of the subject site. Page 8 ITEM VII – GDP SIP – 3463 Compass Way (d) Adequate public infrastructure is or will be available to accommodate the range of uses being proposed for the Planned Development project, including but not limited to public sewer and water and public roads. (e) The proposed Planned Development project will incorporate appropriate and adequate buffers and transitions between areas of different land uses and development densities/intensities. (g) The proposed architecture and character of the proposed Planned Development project is compatible with adjacent/nearby development. (h) The proposed Planned Development project will positively contribute to and not detract from the physical appearance and functional arrangement of development in the area. (i) The proposed Planned Development project will produce significant benefits in terms of environmental design and significant alternative approaches to addressing development performance that relate to and more than compensate for any requested exceptions/base standard modifications variation of any standard or regulation of this Chapter. Staff recommends approval of the General Development Plan and Specific Implementation Plan with the findings listed above with the proposed following conditions: 1. The outdoor storage area shall be screened from the public right-of-way by solid row of evergreen trees or 8’ tall solid fencing. 2. A minimum of 1 parking space shall be provided per employee at the largest work shift. 3. Base Standard Modification to allow increased building height for Redi-mix Plant to 88’, where code allows a maximum building height of 60’. 4. A minimum of 20% of the Redi-mix Plant building facades shall be devoted to Class I materials. 5. Final landscaping plan, lighting plan, and building elevations shall be reviewed and approved by the Department of Community Development. Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20 Page 21