OSHKOSH DT (776305) OSHKOSH, WISCONSIN C-BAND & DoD ADDITION DR AWINGSROOFTOP INSTALL ATION
SCOPE OF WORK SITE LOCATION MAP
1--------,---,-c_-a_a_n_d_&_:_:_D_:_:_:_�_;_<T_so_c_:_E_�_:_s_T _A_L_L_E_D_l c----------1i11' A ANTENNA(S)/EQUIP. 3 C-BAND RADIO(S) W/ BUILT-INANTENNA(S) TO BE INSTALLED � 3 DoD RADKJ(S) W/ BUil T-IN ANTENNA(S) TO BE INST ALL ED I NORTH 1 RAYCAP SPD(S) TO BE INSTALLED t
•_T_R_AN_S�M�ss_I_0_N_�-1�_1_-1_14_"_E _uP_E_N_H_Y_B_R_1D_c_AB_L_E_(s_1 _____ �_T_o_B_E_1N_s_T_AL_L_E_D ___ , ..,_., CABLE(S) MODERNIZAT ION SCOPE (REMAIN/RELOCAT E) ANTENNA(S)/EQUIP. 2 L TE PANEL ANTENNA(S) TO BE RELOCATED 2 TO REMAIN
I ._•
R1vers1Ge t�metery'
Pajne Art Center A and Gardens T -5tl oshA�.e.... 21
Mc□on;:ild's �
MillersBayft Restoration s_rre Y'
Ames Pornt
TRANSMSSION CABLE(S) 2 RAYCAP SPD(S) 1-1/4" EUPEN HYBRID CABLE(S) TO REMAIN P.ollock Communrty t;;.') Water Park Y university of Wisconsin-Oshkosh
TRANSMSSION CABLE(S)
CO/l:X JUMPERS:
GPS ANTENNA(S):
CABLE ROUTE:
GROUND BAR(S):
EQUIPMENT: GROUND BAR(S):
EQUIPMENT: AUX RACK:
CDMA & LAA SCOPE (DECOM) 4 7/8" CDMA CO/l:X TO BE REMOVED EXISTING CDMA CO/l:X JUMPERS TO BE REMOVED
BUILDING SCOPE QTY. EQUIPMENT ACTION 1 CDMAGPS ANTENNA(S) TO BE REMOVED 1 L TE GPS ANTENNA(S) TO REMAIN 1 C-BAND & DoD GPS ANTENNA(S) TO BE INST ALL ED CABLE TRAYS ADEQUATE -TO REMAIN PENTHOUSE CABLE PENETRATION(S) ADEQUATE -TO REMAIN SECTOR GROUND BAR' ADEQUATE -TO REMAIN
EQUIPMENT ROOM INTERIOR SCOPE MODERNIZAT ION SCOPE (REMAIN/RELOCAT E) 2 RAYCAP SPD(S) GROUND BAR AT CO/l:X PORT' C-Band & DoD SCOPE (T O BE INST ALLED) RAYCAP PDU(S) BASE BAND UNIT (BBU)
TO REMAIN TO REMAIN
TO BE INST ALL ED BY OTHERS
Oshkosh Westn High School Y Tiif\.A.,e
i9Marcus Oshkosh Cinema
a. Red Robin Gourmet T Burge•s and Brews
•1atn�
South Par
STRUCTURAL
0sh osh Menom2ee Park9 1
Best Western Premier TheWatersQ
::::�� r� WSMheo<,..
"\ -�.,__ 7 1 n Pele'sGa,agesacf_ !'-:1'''ll I ( ;���) " " " '5-i:'. }!___ rT? " (J l nHuohes Ho-no !J\I I I H
APPLICABLE CODES RAYCAP FIBER TRAY(S) TO BE INSTALLED
,/
INVENTORY REPORT: CDMA SCOPE (DECOM) EDGE CONSULTING ENGINEERS, INC. l EQUIPMENT RACK: 2 CDMA EQUIPMENT RACK(S) TO BE REMOVED ST:�;��:�::::YSIS:DATED: 05/08/2023 0 !• BRING UP TO U.S. CELLULAR STANDARDS AS NECESSARY EDGE CONSULTING ENGINEERS.,.._ f;.-(�
THESE SITE PLANS ADHERE TO ALL OF THE REQUIREMENTS CALLED OUT IN THE JURISDICTION, PLANNING, AND ZONING FOR ANTENNAS AND SUPPORT STRUCTURE WHERE SITE IS LOCATED.
�""51 •----------------------------------0 REPORT#: TBD DATED: Ji,.f/� CONCLUSION: ,,._o••
SPECIAL REQUIREMENTS � V l5 1-------------------------------1 MOUNT ANALYSIS (Po' ·�c::MENT/EXISTING): � NEW STANDOFF WALL MOUNTS REQUIRED AT (3) LOCATIONS. ?-( , c:NGINEERS, INC. ~• SEE MOUNT ANALYSIS LISTED ON THIS SHEET FOR DETAILS. DATED: � ANTENNAS, MOUNTS AND HARDWARE TO BE PAINTED TO MATCH BUILDING COLOR. gg
�S!�---------LO-NG_E_R-FI-B-ER_AN_D_P _O _W_E_R_J_U _MP_E_R_S_(_2_0m_)_R_E_Q_U_IR_E_D_D_U_E_T_O ________ '"C..,. _______________________ ◄ ,, RAYCAP SPD TO INTEGRATED ANTENNA/RAD Kl SEPARATION. r CONTRACTOR TO REVIEW STRUCTURAL REPORT IN ITS ENTIRETY. ANY DISCREPANCIES OR DISAGREEMENTS BElWEEN THE REPORT AND THESE PLANS SHOULD BE RESOLVED PRIOR TO CONSTRUCTION.
ALL WORK SHALL COMPLY WITH THE FOLLOWING: -2015 INTERNATIONAL BUILDING CODE -2017 NATIONAL ELECTRIC CODE
IN THE EVENT OF CONFLICT THE MOST RESTRICTIVE CODE SHALL PREVAIL.
DIRECTORY CLIENT: U.S. CELLULAR 8410 W. BRYN MAWR AVE., SUITE 700 CHICAGO, IL 60631 CONTACT: MICHELE ROTH ENGINEERING COMPANY: EDGE CONSULTING ENGINEERS, INC. 624 WATER STREET PRAIRIE DU SAC, WI 53578 PROJECT MANAGER: MICHAEL MUEHRER
PROJECT INFO
SITE LOCATION: 530 N. MAIN STREET OSHKOSH, WI 54901 WINNEBAGO COUNTY SITE#: 776305 BUILDING OWNER: OSHKOSH HOUSING AUTHORITY 600 MERRIT AVE OSHKOSH, WI 54901 SITE COORDINATES: LAT: 44.020400° LONG: -88.537200°
TO OBTAIN LOCATION OF PARTICIPANTS' UNDERGROUND FACILITIES BEFORE YOU DIG IN WISCONSIN, CALL DIGGERS HOTLINE TOLL FREE: 1-800-242-8511 FAX ALOCATE: 1-800-242-5811 WI STATUTE 182.0175 (1974) REQUIRES MIN. OF 3 WORK DAYS NOTICE BEFORE YOU EXCAVATE
NO.: G--001 C-101 C-102 C-501 A-101 A-501 T-001 T-201 T-301 T-501 T-502 T-503 V-501 P-501 E-501
SHEET INDEX
SHEET TITLE TITLE SHEET SITE PLAN ENLARGED SITE PLAN GPS DETAILS EQUIIPMENT ROOM INTERIOR PLAN BLOCK DIAGRAM EQUIPMENT SPECIFICATIONS SITE ELEVATION ANTENNA CONFIGURATION INSTALLATION DETAILS CABLE DETAILS CABLE BANDING DETAILS CABLE ROUTING PLUMBING DIAGRAM GROUNDING DETAILS
CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS/CONDITIONS ON SITE. IMMEDIATELY NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO PERFORMING ANY WORK OR BE RESPONSIBLE FOR THE SAME.
CONSULTANT:
�Edge Canault:lng Engln••-• Inc. 624 WATER STREET PRAIRIE DU SAC, WI 53578 608.644.14411 VOICE 608.644.1549 FAX www.edgeconsullcom
CLIENT:
*uscellularU.S. CELLULAR 8410W. BRYN MAWRAVE. SUITE 700 CHICAGO, IL 60631
ENGINEER SEAL:
I HEREBY CERTIFY THAT THIS PLAN SET WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION OTHER THAN THE EXCEPTIONS NOTED IN THE SHEET INDEX, AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF WISCONSIN.
SUBMITTAL: INT. DATE: DESCRIPTION: TAS 06/09/2023 REV. A
CHECKED MRMBY
PLOT 6/9/2023 DATE
PROJECT 37397 NUMBER SET DRAFT TYPE
SHEET G-001NUMBER
@ EDGE CONSUL TING ENGINEERS, INC.
A-101
E
D
E
Q
U
I
P
M
E
N
T
R
O
O
M
I
N
T
E
R
I
O
R
P
L
A
N
NORTH
A
PROPOSED EQUIP. ROOM INTERIOR LAYOUT
22" x 34" - 1/4" = 1'-0"
SCALE: 11" x 17" - 1/8" = 1'-0"
EXISTING AUX EQUIPMENT RACK
EXISTING POWER BAY RACK
CABLE TRAY FOR CABLE ROUTING
CONTRACTOR TO USE EXISTING OVERHEAD
GROUND BAR (TYP.)
HYBRID CABLE
(1) PROPOSED 1-1/4" EUPEN
AS NEEDED AT RACK
MANAGEMENT SYSTEM
INSTALL CABLE
DISTRIBUTION UNIT (PDU);
FEEDS TO RAYCAP POWER
PROPOSED DC POWER
INNERDUCT AND COLD SHRINK
INSTALL WITH 3" MIN. OVERLAP ON BOTH
PORT TO EXPOSE INTERNAL CABLE FEEDS;
PROPOSED CABLE OUTER SHIELD TO COAX
GENERAL CONTRACTOR REMOVE
ZIP-TIES
LADDER WITH CROSSED
SECURE TO CABLE
TO RAYCAP FIBER TRAY;
PROPOSED FIBER FEEDS
INSTALL IN HIGHEST AVAILABLE POSITION IN RACK
SPECIFIC BAND OF SERVICE;
GENERAL CONTRACTOR TO LABEL EACH WITH
RAYCAP MODEL #: RTF-3001;
INSTALLED IN EXISTING AUX RACK;
(1) PROPOSED RAYCAP FIBER TRAY TO BE
AUX RACK BY ICI VENDOR
TO BE INSTALLED IN EXISTING
FUTURE BASEBAND UNIT (BBU)
TO SIDE OF POWER BAY RACK
DISTRIBUTION UNIT (PDU) SECURED
(1) PROPOSED RAYCAP POWER
RAYCAP SPD (TYP. OF 2)
EXISTING WALL MOUNTED
TO BE REMOVED
AND ASSOCIATED RADIO EQUIPMENT
EXISTING CDMA EQUIPMENT RACKS
AND MULTI-CIRCUIT, DISTRIBUTED ANTENNA SYSTEMS.
DISTRIBUTION SYSTEM FOR USE IN REMOTE RADIO HEAD (RRH)
2RU RACK MOUNTED DC SURGE SUPPRESSION AND POWER
CABLE STORAGE: RTF-6601
25A CIRCUIT BREAKER: AMCB-48-0125
40A CIRCUIT BREAKER: AMCB-48-0140
9 BREAKER KIT FOR NOKIA RADIO SET: AMCB-48-0640-0325-KIT
12 BREAKER KIT FOR ERICSSON RADIO SET: AMCB-48-1225-KIT
OPTIONAL ACCESSORIES
22 LBS (WITHOUT BREAKERS)WEIGHT:
18.99" x 19.00" x 3.48" (D x W x H)DIMENSIONS:
RUSDC-1176-PDU-48-AMCB-1240 (12 x 40A BREAKERS INCLUDED)
RUSDC-1176-PDU-48 (BREAKERS NOT INCLUDED)MODEL:
RAYCAPMANUFACTURER:
F
RAYCAP POWER DISTRIBUTION UNIT (PDU)
C EXISTING RAYCAP SPD(S)B EXISTING RAYCAP SPD(S)
RACK
BAY
POWER
BACKUP RACKS
BATTERY
RACK
EQUIP.
CDMA
RACK
EQUIP.
CDMA
IN AREA ABOVE ELEVATOR SHAFTS
CABLE ROUTED THROUGH FRAMED
PROPOSED U.S. CELLULAR HYBRID
EXISTING COAX PORTEXISTING COAX PORT
WITH (2) OPEN PORTS
INTO PENTHOUSE SECOND FLOOR
EXISTING 16-HOLE COAX PORT
RACK
AUX
RACK
LTE
EXISTING COAX PORT
ANTENNA ON COAX HOOD
ROUTED FROM AUX RACK TO PROPOSED GPS
PROPOSED C-BAND/DoD GPS CABLE TO BE
ROOFTOP COAX HOOD
EXISTING COAX PORT BELOW SEE PAGE T-502
AT BETA GAMMA SECTOR;
MOUNTED INSIDE PENTHOUSE
SECTOR RAYCAP SPD POST
PROPOSED U.S. CELLULAR
DATE:DESCRIPTION:
SUBMITTAL:
INT.
SHEET
NUMBER
6/9/2023
O:
\
3
7
3
0
0
\
3
7
3
9
7
\
D
e
s
i
g
n
\
C
A
D
\
C
D
\
P
l
o
t
\
A
-
1
0
1
.
d
g
n
37397
TAS 06/09/2023
BY
CHECKED
DATE
PLOT
NUMBER
PROJECT
TYPE
SET
CONSULTANT:
CLIENT:
www.edgeconsult.com
608.644.1549 FAX
608.644.1449 VOICE
PRAIRIE DU SAC, WI 53578
624 WATER STREET
W
I
S
C
O
N
S
I
N
,
O
S
H
K
O
S
H
)
7
7
6
3
0
5
(
O
S
H
K
O
S
H
D
T
REV. A
DRAFT
CHICAGO, IL 60631
SUITE 700
8410 W. BRYN MAWR AVE.
U.S. CELLULAR
MRM
STATE OF WISCONSIN.
UNDER THE LAWS OF THE
PROFESSIONAL ENGINEER
THAT I AM A DULY LICENSED
NOTED IN THE SHEET INDEX, AND
OTHER THAN THE EXCEPTIONS
UNDER MY DIRECT SUPERVISION
SET WAS PREPARED BY ME OR
I HEREBY CERTIFY THAT THIS PLAN
ENGINEER SEAL:
NOT FOR CONSTRUCTION- PRELIMINARY -
(CIRCULAR)
POLE MOUNT WALL MOUNT
(SQUARE)
POLE MOUNT
(90° ANGLE)
POLE MOUNT
BOTTOM VIEW
FRONT VIEW SIDE VIEW
PLAN VIEW
FRONT VIEW SIDE VIEW
PLAN VIEW
FRONT VIEW SIDE VIEW
T-001
E
Q
U
I
P
M
E
N
T
S
P
E
C
I
F
I
C
A
T
I
O
N
S
A
RAYCAP SURGE PROTECTOR DEVICE (SPD)
19.95 LBSWEIGHT:
20.6" x 18.9" x 5.8" (H x W x D)DIMENSIONS:
: RUSDC-6267-PF-48MODEL
: RAYCAPMANUFACTURER
18.9"
1
8
.
9
"
20
.
6
"
5.8"
FRAME OR WALL MOUNT
ENCLOSURE MOUNTS FOR H-
REMOVE BRACKET AND USE
MOUNTING BRACKET INCLUDED;
MOUNTING TO POLE
V-CLAMP FOR
INCLUDED WITH RAYCAP SPD.
: MOUNTING BRACKETMODEL
: RAYCAPMANUFACTURER
B
RAYCAP SURGE PROTECTOR DEVICE (SPD) MOUNT
HARDWARE
MOUNTING
HOLES FOR
HARDWARE
MOUNTING
HOLES FOR
NUT
LOCK WASHER
WASHER
BOLT
WASHER
13.0 LBS. (SWIVEL ANGLE AND TILT ANGLE)
WEIGHT: 9.7 LBS. (SWIVEL ANGLE)
SXK 109 2065/1 (SWIVEL ANGLE AND TILT ANGLE)
SXK 109 2064/1 (SWIVEL ANGLE):MODEL
: ERICSSONMANUFACTURER
ERICSSON SWIVEL MOUNT KIT
0°
30°30°
82.7 LBS.WEIGHT:
30.6" x 15.9" x 10.6" (H x W x D)DIMENSIONS:
: AIR6449MODEL
: ERICSSONMANUFACTURER
ERICSSON AIR6449
10.6"15.9"
3
0
.
6
"
44.1 LBS.WEIGHT:
28.2" x 16.1" x 5.5" (H x W x D)DIMENSIONS:
: AIR6419MODEL
: ERICSSONMANUFACTURER
ERICSSON AIR6419
5.5"16.1"
2
8
.
2
"
THIS SPACE INTENTIONALLY LEFT BLANK
DATE:DESCRIPTION:
SUBMITTAL:
INT.
SHEET
NUMBER
6/9/2023
O:
\
3
7
3
0
0
\
3
7
3
9
7
\
D
e
s
i
g
n
\
C
A
D
\
C
D
\
P
l
o
t
\
T
-
0
0
1
.
d
g
n
37397
TAS 06/09/2023
BY
CHECKED
DATE
PLOT
NUMBER
PROJECT
TYPE
SET
CONSULTANT:
CLIENT:
www.edgeconsult.com
608.644.1549 FAX
608.644.1449 VOICE
PRAIRIE DU SAC, WI 53578
624 WATER STREET
W
I
S
C
O
N
S
I
N
,
O
S
H
K
O
S
H
)
7
7
6
3
0
5
(
O
S
H
K
O
S
H
D
T
REV. A
DRAFT
CHICAGO, IL 60631
SUITE 700
8410 W. BRYN MAWR AVE.
U.S. CELLULAR
MRM
STATE OF WISCONSIN.
UNDER THE LAWS OF THE
PROFESSIONAL ENGINEER
THAT I AM A DULY LICENSED
NOTED IN THE SHEET INDEX, AND
OTHER THAN THE EXCEPTIONS
UNDER MY DIRECT SUPERVISION
SET WAS PREPARED BY ME OR
I HEREBY CERTIFY THAT THIS PLAN
ENGINEER SEAL:
NOT FOR CONSTRUCTION- PRELIMINARY -
C
ED
T-201
S
I
T
E
E
L
E
V
A
T
I
O
N
C U.S. CELLULAR ALPHA SECTOR ANTENNAS
D U.S. CELLULAR BETA SECTOR ANTENNAS
E U.S. CELLULAR GAMMA SECTOR ANTENNASBEXISTING SITE ELEVATION
SEE T-301 FOR DETAILS
ANTENNAS ON EXISTING MOUNTS;
EXISTING U.S. CELLULAR PANEL
SEE T-301 FOR DETAILS
MOUNTS;
ANTENNA/RADIO ON PROPOSED
C-BAND AND DoD INTEGRATED
PROPOSED U.S. CELLULAR
A
SITE ELEVATION
C
/
L
O
F
P
R
O
P
O
S
E
D
U
.
S
.
C
E
L
L
U
L
A
R
C
-
B
A
N
D
I
N
T
E
G
R
A
T
E
D
A
N
T
E
N
N
A
/
R
A
D
I
O
@
1
0
2
'
-
6
"
A
G
L
C/
L
O
F
P
R
O
P
O
S
E
D
U
.
S
.
C
E
L
L
U
L
A
R
C
-
B
A
N
D
I
N
T
E
G
R
A
T
E
D
A
N
T
E
N
N
A
/
R
A
D
I
O
@
1
3
0
'
-
6
"
A
G
L
WHIP ANTENNA
EXISTING CARRIER
EXISTING FLAG POLE
PANEL ANTENNAS
EXISTING CARRIER
INSIDE PENTHOUSE
EQUIP. ROOM
U.S. CELLULAR
COAX HOOD
EXISTING ROOFTOP
EX. A/C UNITS
ALONG SIDE EXISTING COAX
PRO. HYBRID CABLE ROUTING
THE BASE OF ANTENNA
WHERE CABLES EXTEND OUT AND ATTACH TO
BE VISIBLE FROM GROUND LEVEL, OTHER THAN
TUCKED BEHIND ANTENNA. CABLES SHOULD NOT
- ROUTE JUMPERS AND CABLES IN A NEAT MANNER,
BELOW ROOF PARAPET AND OR PENTHOUSE
ANTENNAS AND RELATED MOUNTS TO BE LOCATED
MATCH EXISTING BUILDING AND PENTHOUSE. ALL
- ALL ANTENNAS & HARDWARE TO BE PAINTED TO
NOTE:
C
/
L
O
F
P
R
O
P
O
S
E
D
U
.
S
.
C
E
L
L
U
L
A
R
D
o
D
I
N
T
E
G
R
A
T
E
D
A
N
T
E
N
N
A
/
R
A
D
I
O
S
@
9
9
'
-
0
"
A
G
L
C/
L
O
F
P
R
O
P
O
S
E
D
U
.
S
.
C
E
L
L
U
L
A
R
D
o
D
I
N
T
E
G
R
A
T
E
D
A
N
T
E
N
N
A
/
R
A
D
I
O
S
@
1
2
7
'
-
0
"
A
G
L
C/
L
O
F
P
R
O
P
O
S
E
D
U
.
S
.
C
E
L
L
U
L
A
R
D
o
D
I
N
T
E
G
R
A
T
E
D
A
N
T
E
N
N
A
/
R
A
D
I
O
S
@
1
1
8
'
-
6
"
A
G
L
C/
L
O
F
P
R
O
P
O
S
E
D
U
.
S
.
C
E
L
L
U
L
A
R
C
-
B
A
N
D
I
N
T
E
G
R
A
T
E
D
A
N
T
E
N
N
A
/
R
A
D
I
O
@
1
2
3
'
-
6
"
A
G
L
DATE:DESCRIPTION:
SUBMITTAL:
INT.
SHEET
NUMBER
6/9/2023
O:
\
3
7
3
0
0
\
3
7
3
9
7
\
D
e
s
i
g
n
\
C
A
D
\
C
D
\
P
l
o
t
\
T
-
2
0
1
.
d
g
n
37397
TAS 06/09/2023
BY
CHECKED
DATE
PLOT
NUMBER
PROJECT
TYPE
SET
CONSULTANT:
CLIENT:
www.edgeconsult.com
608.644.1549 FAX
608.644.1449 VOICE
PRAIRIE DU SAC, WI 53578
624 WATER STREET
W
I
S
C
O
N
S
I
N
,
O
S
H
K
O
S
H
)
7
7
6
3
0
5
(
O
S
H
K
O
S
H
D
T
REV. A
DRAFT
CHICAGO, IL 60631
SUITE 700
8410 W. BRYN MAWR AVE.
U.S. CELLULAR
MRM
STATE OF WISCONSIN.
UNDER THE LAWS OF THE
PROFESSIONAL ENGINEER
THAT I AM A DULY LICENSED
NOTED IN THE SHEET INDEX, AND
OTHER THAN THE EXCEPTIONS
UNDER MY DIRECT SUPERVISION
SET WAS PREPARED BY ME OR
I HEREBY CERTIFY THAT THIS PLAN
ENGINEER SEAL:
NOT FOR CONSTRUCTION- PRELIMINARY -
ANTENNA/RADIO
PROPOSED C-BAND INTEGRATED
ANTENNA/RADIO
PROPOSED DoD INTEGRATED
DETAILS
SEE MOUNT ANALYSIS LISTED ON SHEET G-001 FOR
MOUNTING PIPE ON NEW STANDOFF WALL MOUNTS;
PROPOSED 2-1/2" SCH 40 (2-7/8" O.D.) x 16' LONG
STANDOFF WALL MOUNT
TO BE RELOCATED TO NEW
EXISTING AWS/LTE PANEL ANTENNA
STANDOFF WALL MOUNT
TO BE RELOCATED TO NEW
EXISTING AWS/LTE PANEL ANTENNA
DETAILS
SEE MOUNT ANALYSIS LISTED ON SHEET G-001 FOR
MOUNTING PIPE ON NEW STANDOFF WALL MOUNTS;
PROPOSED 2-1/2" SCH 40 (2-7/8" O.D.) x 10' LONG
ANTENNA/RADIO
PROPOSED C-BAND INTEGRATED
ANTENNA/RADIO
PROPOSED DoD INTEGRATED
DETAILS
SEE MOUNT ANALYSIS LISTED ON SHEET G-001 FOR
MOUNTING PIPE ON NEW STANDOFF WALL MOUNTS;
PROPOSED 2-1/2" SCH 40 (2-7/8" O.D.) x 16' LONG
ANTENNA/RADIO
PROPOSED C-BAND INTEGRATED
ANTENNA/RADIO
PROPOSED DoD INTEGRATED
T-501
I
N
S
T
A
L
L
A
T
I
O
N
D
E
T
A
I
L
S
A PROPOSED ALPHA SECTOR INSTALLATION
D
8" STANDOFF ANTENNA WALL MOUNT
PLATE (ORDERED SEPARATELY)
24" LONG GALVANIZED CHANNEL BACKING
APPROVED EQUIVALENT
SITE PRO 1 PART #MM01 OR
8" STANDOFF ANTENNA WALL MOUNT;
MANUFACTURER: SITE PRO 1
MODEL: MM01
8" STANDOFF ANTENNA WALL MOUNT
U-BOLTS FOR 2-3/8" O.D. & 2-7/8" O.D.
MOUNTING PIPES INCLUDED
IF MOUNTING A 3-1/2" O.D. PIPE, PURCHASE
U-BOLTS (UB1358) SEPARATELY
MOUNTING HOLES ARE 11/16" ON 6" CENTERS
PURCHASE MOUNTING PIPES SEPARATELY
VERIFY WITH MOUNT ANALYSIS IDENTIFIED ON G-001
DETAIL INCLUDED FOR CONVENIENCE ONLY
B PROPOSED BETA SECTOR INSTALLATION
C PROPOSED GAMMA SECTOR INSTALLATION
DATE:DESCRIPTION:
SUBMITTAL:
INT.
SHEET
NUMBER
6/9/2023
O:
\
3
7
3
0
0
\
3
7
3
9
7
\
D
e
s
i
g
n
\
C
A
D
\
C
D
\
P
l
o
t
\
T
-
5
0
1
.
d
g
n
37397
TAS 06/09/2023
BY
CHECKED
DATE
PLOT
NUMBER
PROJECT
TYPE
SET
CONSULTANT:
CLIENT:
www.edgeconsult.com
608.644.1549 FAX
608.644.1449 VOICE
PRAIRIE DU SAC, WI 53578
624 WATER STREET
W
I
S
C
O
N
S
I
N
,
O
S
H
K
O
S
H
)
7
7
6
3
0
5
(
O
S
H
K
O
S
H
D
T
REV. A
DRAFT
CHICAGO, IL 60631
SUITE 700
8410 W. BRYN MAWR AVE.
U.S. CELLULAR
MRM
STATE OF WISCONSIN.
UNDER THE LAWS OF THE
PROFESSIONAL ENGINEER
THAT I AM A DULY LICENSED
NOTED IN THE SHEET INDEX, AND
OTHER THAN THE EXCEPTIONS
UNDER MY DIRECT SUPERVISION
SET WAS PREPARED BY ME OR
I HEREBY CERTIFY THAT THIS PLAN
ENGINEER SEAL:
NOT FOR CONSTRUCTION- PRELIMINARY -