Contractor's Material and Test Certificate for Aboveground Piping
PROCEDURE
Upon completion of work,inspection and tests shall be made by the contractor's representative and witnessed by the property owner or their authorized agent. All
defects shall be corrected and system left in service before contractor's personnel finally leave the job.
A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities,owners,and contractor. It is understood the
owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship,or failure to comply with approving
authorit 's requirements or local ordinances.
PROPERTY NAME Evco Plastics AFP Contract# 491196 DATE: June 21, 2012
PROPERTY ADDRESS 450 Ripple Avenue Oshkosh, WI 54902
ACCEPTED BY APPROVING AUTHORITIES (NAMES)
1. Oshkosh Fire Department (Battalion Chief—Mike Augsburger)
2. City of Oshkosh (Building Inspector—Brian Noe)
3. CNA Insurance (Mr. Scott J. MacPherson)
4.
ADDRESS
Plans 1. 101 Court Street - Oshkosh, WI 54901
2. 215 Church Avenue - PO Box 1130 -Oshkosh, WI 54901
3. 13845 Bishops Drive, Suite 100- Brookfield, WI 53005
4.
INSTALLATION CONFORMS TO ACCEPTED PLANS 91 YES ❑ NO
EQUIPMENT USED IS APPROVED ❑YES ❑N O
IF NO,EXPLAIN DEVIATIONS
HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO LOCATION 49rYES ❑N O
OF CONTROL VALVES AND CARE AND MAINTENANCE OF THIS NEW EQUIPMENT?
INSTRUCTIONS IF NO, EXPLAIN
HAVE COPIES OF THE FOLLOWING BEEN LEFT ON THE PREMISES:
Item No.'s 2&3 will 1. SYSTEM COMPONENTS INSTRUCTIONS RYES ❑N O
be forwarded by AFP at closeout time. 2 CARE AND MAINTENANCE INSTRUCTIONS ®'YES ❑N,O
3. NFPA 25 FrYES ❑NO
LOCATION OF SUPPLIES BUILDINGS
SYSTEM System 4 (Revised)
MAKE MODEL YEAR OF K- QUANTITY TEMPERATURE
MANUFACTURE FACTOR RATING
Viking Micromatic VK200 Upright 3/4"Brass 2012 8.0 142 286 Deg.
Reliable JL-17 RA1914 Pendent 3/4"Brass 2012 16.8 210 165 Dea.
SPRINKLERS
PIPE AND TYPE OF PIPE Schedule 7; Schedule 30; Black
FITTINGS TYPE OF FITTINGS Grooved;Threaded;Welded Outlets
FLOW ALARM DEVICE MAXIMUM TIME TO OPERATE
THROUGH TEST CONNECTION
TYPE MAKE MODEL MINUTES SECONDS
Water Flow Detector System Sensor WFD
N/A
EXPLAIN ANY ALARM PROBLEMS:
ALARM
DEVICES LOW AIR ALARM DEVICE ALARM OPERATED
PRESSURE
TYPE MAKE MODEL PROPERLY
N/A SETTING PSI YES NO
EXPLAIN ANY ALARM PROBLEMS:
Ahern
CENTRAL MONITORING SIGNALS RECEIVED
ALARM SERVICE LOCATION(S)
TYPE OR PRESSURE
NAME OF'REMOTE WATERFLOW SWITCH LOW—AIR OTHER
SERVICE DETECTOR FLOW SUPERVISORY
SUPERVISING LOCATION(S)-
STATI(ON-SITE)
¢ r
l
REMOTE NAME OF SERVICE:
REMOTE MONITORING
ALRMSERVICE
SIGNALING
(OFF—SITE)
PHONE: , .3
OTHER: LOCATION(S):
EXPLAIN ANY ALARM SIGNALING PROBLEMS:
DRY VALVE Q.O.D.
MAKE MODEL SERIAL NO. MAKE MODEL SERIAL NO.
DRY PIPE TIME TO TRIP TIME WATER ALARM
OPERATING WATER TRIP POINT AIR
THROUGH TEST AIR PRESSURE REACHED TEST OPERATED
CONNECTIONab PRESSURE PRESSURE ,
TEST OUTLETa 'PROPERLY
MIN. SEC. PSI PSI PSI MIN. SEC. YES NO
WITHOUT
Q.O.D.
WITH
Q.O.D.
IF NO, EXPLAIN:
OPERATION: ❑ PNEUMATIC ❑ ELECTRIC ❑ HYDRAULIC
PIPING SUPERVISED ❑YES ❑ NO DETECTING MEDIA SUPERVISED ❑YES El NO
DOES VALVE OPERATE FROM THE MANUAL TRIP, REMOTE, OR BOTH CONTROL STATIONS? ❑YES ❑NO
IS THERE AN ACCESSIBLE FACILITY IN EACH IF NO, EXPLAIN
DELUGE& CIRCUIT FOR TESTING?
PREACTION ❑YES ❑NO
VALVES
DOES EACH CIRCUIT DOES EACH CIRCUIT MAXIMUM TIME TO
OPERATE SUPERVISION OPERATE VALVE OPERATE RELEASE
MAKE MODEL LOSS ALARM? RELEASE?
YES NO YES NO MINUTES SECONDS
LOCATION & MAKE&MODEL SETTING STATIC PRESSURE RESIDUAL PRESSURE FLOW RATE
PRESSURE FLOOR (FLOWING)
REDUCING INLET OUTLET INLET OUTLET FLOW
VALVE TEST (PSI) (PSI) (PSI) (PSI) (GPM)
a MEASURED FROM TIME INSPECTORS TEST CONNECTION IS OPENED.
NFPA 13 ONLY REQUIRES THE 60-SECOND LIMITATION IN SPECIFIC SECTIONS.
2
Ahern
HYDROSTATIC: Hydrostatic tests shall be made at not less than 200 psi(13.6 bar)for two(2)hours or 50 psi(3.4 bar)above static pressure in
excess of 150 psi(10.2 bar)for two(2)hours. Differential dry-pipe valve clappers shall be left open during test to prevent damage. All
TEST aboveground piping leakage shall be stopped.
DESCRIPTION
PNEUMATIC: Establish 40-psi(2.7 bar)air pressure and measure drop,which shall not exceed 1-1/2 psi(0.1 bar)in 24 hours. Test pressure
tanks at normal water level and air pressure and measure air pressure drop,which shall not exceed 1-1/2 psi(0.1 bar) in 24 hours.
ALL PIPING HYDROSTATICALLY TESTED AT PSI (_Bar)for HRS. IF NO, STATE REASON
DRY PIPING PNEUMATICALLY TESTED YES f'NO
EQUIPMENT OPERATES PROPERLY jjrYES ❑ NO
DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT ADDITIVES AND CORROSIVE CHEMICALS, SODIUM
SILICATE OR DERIVATIVES OR SODIUM SILICATE, BRINE, OR OTHER CORROSIVE CHEMICALS WERE NOT USED
FOR TESTING SYSTEMS OR STOPPING LEAKS?
YES ❑NO
DRAIN I READING OF GAUGE LOCATED NEAR WATER RESIDUAL PRESSURE WITH VALVE IN TEST
TEST SUPPLY TEST CONNECTIO 3 PSI ( Bar) CONNECTION OPEN WIDE: PSI (_Bar)
TESTS UNDERGROUND MAINS AND LEAD IN CONNECTIONS TO SYSTEM RISER(S)TO OTHER EXPLAIN
BE FLUSHED BEFORE CONNECTION MADE TO SPRINKLER PIPING.
VERIFIED BY COPY OF THE CONTRACTOR'S MATERIAL AND TEST
CERTIFICATE FOR UNDERGROUND PIPING. ❑YES R NO Ei
FLUSHED BY INSTALLER OF UNDERGROUND SPRINKLER PIPING ❑YES NO
IF POWDER-DRIVEN FASTENERS ARE USED IN CONCRETE, HAS IF NO, EXPLAIN
REPRESENTATIVE SAMPLE TESTING BEEN SATISFACTORILY COMPLETED?
❑YES WNO
BLANK NUMBER USED LOCATIONS NUMBER REMOVED
TESTING
GASKETS
_WELDEDPIPING NYES ❑ NO
IF YES...
Do you certify as the sprinkler contractor that welding procedures used complied with the minimum
requirements of AWS 132.1,ASME Section IX Welding and Brazing Qualifications, or other applicable YES ❑N O
qualification standard as required by the AHJ?
Do you certify that all welding was performed by welders or welding operators qualified in accordance SKYES ❑ NO
WELDING with the minimum requirements of AWS 132.1,ASME Section IX Welding and Brazing Qualifications,
or other applicable qualification standard as required by the AHJ?
Do you certify that the welding was conducted in compliance with a documented quality control
procedure to ensure that(1)all discs are retrieved;(2)that openings in piping are smooth,that slag ZWYES ❑ NO
and other welding residue are removed; (3)the internal diameters of piping are not penetrated;(4)
completed welds are free from cracks,incomplete fusion,surface porosity greater than 1/16 inch
diameter, undercut deeper than the lesser of 25%of the wall thickness or 1/32 inch;and(5)completed
circumferential butt weld reinforcement does not exceed 3/32 inch?
CUTOUTS DO YOU CERTIFY THAT YOU HAVE A CONTROL FEATURE TO ENSURE THAT ALL ES ❑ NO
DISCS CUTOUTS DISCS ARE RETRIEVED?
HYDRAULIC NAMEPLATE P_ROVDED IF NO, EXPLAIN
DATA YES ❑NO
NAMEPLATE
REMARKS DATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN: f
NAME OF SPRINKLER CONTRACTOR
AHERN, 855 MORRIS STREET—FOND DU LAC,WI 54935
TESTS WITNESSED BY
AUTHORITIES HAVING JURISDICTION (SIGNED) TITLE DATE
SIGNATURES (� � 4-Q-2`2010
TH OPERTY OWN4 THEIR AUTHORIZED AGENT(SIGNED) TITLE �TE
,a:
PRINKLE 0 TOR( NED) TITL DATE
ADDITIONAL E)PLANA] ONS AND N TES:
3