Loading...
HomeMy WebLinkAbout0103031-BuildingOSHKOSH ON THE WATER ,Job Address 3213 BELLFIELD DR Designer Category CITY OF OSHKOSH No 103031 BUILDING PERMIT -APPLICATION AND RECORD Owner CREATIVE CUSTOM HOMES Create Date 06/27/2003 Contractor CREATrVE CUSTOM HOMES, INC 110 - New Single Family · Building (~ Sign (~ Canopy (~ Fence Type Zoning R-1 Class of Const: 8 Unfinished/Basement 1117 Sq. Ft. Rooms 7 Height Finished/Living 1730 Sq. Ft. Bedrooms 3 Stories 2 Garage 422 Sq. Ft. Baths 3 Foundation · Poured Concrete O Floating Slab (~) Pier (~ Other C) concrete Block (~ Post (~ Treated Wood Occupancy Permit Required Flood Plain No Park Dedication Required # Dwelling Units I Raze Plan 25 Ft. Size IRRG [] Projection Canopies 0 Signs 0 Height Permit Not Required # Structures 1 Use/Nature of Work NSFR/ 2 Stow with attached 2 car garage and 12' x 12' patio. Driveway will be 18' wide. HVAC Contractor Electric Contractor Fees: Valuation Issued By: ~ MARTENS HEATING & COOLING VAN ERT ELECTRIC $112,000.00 Plan Approval $75.00 Permit Fee Paid [] Permit Voided Plumbing Contractor HANSON QUALITY PLUMBING $416.00 Park Dedication $100.00 Date 07/23/2003 Final/O.P. 00/00/0000 In the perforrganco of this work I agra. P..!;o perform all work pursuant to rules governing the described construction. Signature'~ ~/'~JJ ~_¢~.__~, Date ~'~=~'~X Address 1087VELP AVE GREEN BAY WI 54303 - 0000 Telephone Number 819-2655 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. OSHKOSH ON THE WATER GRADE STAKE FORM Name CREATIVE CUSTOM HOMES Address Lot 42 Block Subdivision VILLAGE GREEN Zone Street Number Lot Dimensions Building Grade Elevation Stakes Set At Site 06/30/2003 Set By 3213 BELLFIELD DR D.W.G. BK -590, P-10 Grade Stake Number 6974 Create Date 06/27/2003 Sidewalk Existing Ward Department of Public Works I, the undersigned, owner or agent of the above described property agree to have the grade established before excavation has commenced. ¢~~~~ Wisconsin'Departm~nt of Industry, Labor and Human Relations Safety and Buildings Division P.O. Box 2509 Madison, WI 53701-2509 Wisconsin Statues 101.63, 101.73 [] Constr Owner's Name CREATIVE CUSTOM HOMES Contractor: [] Con[~ Elec[] HVAC L~ PIbg CREATIVE CUSTOM HOMES, INC Contractor: ~ Con ~J Elec ~J HVAC~J PIbg VAN ERT ELECTRIC Contractor: ~J Con L~J ElecL~J HVAC LJ PIb[ ~IARTENS HEATING & COOLING Contractor:~ Con ~J Elec~J HVAC~J Plbg HANSON QUALITY PLUMBING Building Address 3213 BELLFIELD DR WISCONSIN UNIFORM Application No. BUILDING PERMIT 0103031 APPLICATION Parcel No. [] HVAC [] Elec [] Plbg [] Erosion [] Other: Mailing Address 1087 VELP AVE Telephone No. GREEN BAY WI 54303 - 0000 Lic/Cert # Mailing Address Telephone No. 679085 1087 VELP AVE GREEN BAY WI 54303 - 0 819-2655 . Lic/Cer~ # Mailing Address Telephone No. 170921 2000 PROGRESS WAY KAUKUANA WI 54130 -0 920-766-3888 Lic/CeA # Mailing Address Telephone No. ;8831 P.O. BOX 106 WAUKAU WI 54980 -106 (920) 685-0111 Mailing Address 550 N BLUEMOUND RD iLic/Cert # Telephone NO. APPLETON WI 54914 -0 730-0205 Sq. ft. Subdivision Name 1/4, 1/4,SectiOnLot No. ,T N,RBiock No. E(or)W V LLAGE GREEN 42 Zoning District(s) Zoning Permit No. Front Rear Left Right New [] Repair Single Family Alteration Two Family Addition [] Raze Garage [] Move ~ Other (print): Other: Site Constructed Unfinished Manufactured Basement 1117 Sq. ft. Living Area 1730 Sq. ff. 1-Story [] 2-Story Garage 422 Sq. fti [] Other Forced Air Furnace Size: [] Fuel Sen/ice: [] Heat Pump Space Htg Overhead ~ Boiler Water Htg Underground Central Air Conditioning unit will have 3 kilowatt or Other more installed electric space heatin Concrete Masonry Infiltration centrol option is: [] Full sealing Sewer of joints. [] Blower door test. [] Exterior Treated Wood [] Municipal air infiltration barrier. Other ~ Septic Permit No. Envelope 28719 BTU/HR [] Seasonal Infiltration 23822 BTU/HR Permanent [] Municipal Utility [] Plus Basement Other ~ Pdvate On-Site Well $133,000.00 The applicant agrees to comply with all applicable codes, statues and ordinances and with the conditions of this permit, understands that the issuance of the permit creates no legal liability, express or imj;)lied, on the De.t~rtment or munJcipality; and certifies that all the above information is accurate. 'P..CA.T'S S .ATURE .ATE APPROVAL CONDITIONS /~s permit is issued pursuant to the following conditions. Failure to comply may result in suspension or revocation of this permit or other penalty SEE "STANDARD CONDITIONS OF APPROVAL" SHEET [] Town [] Village [] City [] County State of: Municipality Number of Dwelling Location: CityOf Oshkosh 7 0 - 2 6 6 Plan Review $75.00 Construction HVAC Name JOHN ZARATE Inspection E~ectrical Wis. Permit Seal $30.00 Plumbing Date 6/27/03 Other Erosion Total $105.00 292155 Certi No. 70330 SBD-5823 (R. 07/92) OSHKOSH ON THE WATER ,Job Address 3213 BELLFIELD DR Name CREATIVE CUSTOM HOMES Address 1087 VELP AVE Subdivision VILLAGE GREEN Building Permit Number Number of Dwelling Units Fee Required Owner's Signature ~ Inspector's Signature PARKLAND DEDICATION FEE COLLECTION RECORD Date 07/23/2003 GREEN BAY Lot 42 0103031 1 $100.00 WI 54303 Number of Structures 1 Fee Paid Date Date ro~' LOT LOT d Grode et Home 185o.51 House House Ground Grade at Home 1850.51 % ~( Garage Grade at Ham [852.81 House rage 'NO ONE GETS YOU MORE THAN THE NEW HOME STORE" N SC. dLE: 1" '= 20' Garage -Site Plan- Village Green-Lot 42 City of Oshkosh, Winnebago County .i'u,~16, 2003 CITY OF OSHKOSH Project Address Permit # Please read the following information and sign at the bottom to acknowledge that you have read and agree to comply with these conditions. All habitable rooms must be provided with 8% light and 3.5% ventilation. Bedrooms located on the second floor or below ground level must be provided with egress windows in addition to the light and ventilation requirements. Basement windows are also required to have window well areas in accordance with ILHR 21.03. Garage spaces shall be separated from the dwelling unit in accordance with ILHR 21:08. The door and frame assembly between the dwelling unit and an attached garage shall be labeled by an independent testing a~encv as having a minimum fire-resistive rating of 20 minutes. Ali drywall joints are required to be taped/sealed unless the joints are fitted so that the gap is no more than a dimes thickness (1/20-inch) 0~nd backed by solid wood or drywall with the joints staggered. All penetrations in exterior walls must be sealed prior to the insulation inspection. This includes holes in the top and bottom plates, gaps around heating ducts, and holes in the return air spaces. Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke detectors are required to be hardwired and intereounected. Hydromassage tubs are required to have an access panel to motor. The access panel must be accessible without removing the finish of the house. All overfram~ng must be designed by the truss manufacturer, according to standards set by the truss plate institute, or structural calculations must be provided prior to the rough building inspection. Truss plans must be submitted and approved prior to framing the roof. Truss plans including the miss layout must be provided on site at the rough building inspection. In addition to the truss plans, microlam calculations must be provided an site at the rough building inspection for all microlams with point loads on them. Calculations must be provided for all cantilex/ered flobrs with point loads. Floor trusses and TJI'S must be designed for the cantilevered areas. 10. The property owner and applicant is responsible for compliance with ILHR 21.125 (Erosion Control). When installing access drives, a minimum of 2"-3" diameter stone is required in addition to a minimum of 6" depth, 30'-50' length, and 14'-20' width. Erosion control measures must be maintained until the lawn is established. 11 All storm sewer inlets must be protected with approved erosion control devices. Tracking (i.e. sediment) must be removed from the street at the end of each workday. Repair any siltation or erosion damage to adjoining surfaces and drainageways resulting fi:om land development or disturbing activities. 12. The building placard must be posted on site at all times. Once the rough framing is up the placard must be posted on the patio door or on a kitchen window. If the placard is not present at any inspection, stop work orders will be posted. Additional placards can be obtained through our depamnent if the cards are misplaced. 13. All mechanicals must be roughed in prior to requesting the rough building inspection. If on the inspection the mechanicals are not roughed in, the inspection will fail and a $I00 re-inspection fee will be charged. 14. Attached is a copy of the final inspection checklist. At the fmal inspection all items on this list must be completed to avoid the $100 re-inspection fee per inspection. 15. When requesting final inspections please note that a minimum of 2 days notice is needed from the time the inspection is ready. Furniture is only allowed to be placed in the center of the garage floor and a miniinum 6f~i~3, ]ptith~vay ifl~i~t b~ ~fok)ided~around~the Walls of the garage. At the final inspection no furniture or personal belongings are allowed in the house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in place due to the electrical inspector needing to look at the power serving the appliances. A 6' stepladder must be on site at the final inspection to provide access to the attic. 16. The building placard must remain on the patio door or on a kitchen window until occupancy is approved. Occupancy is not allowed prior to the placard having all of the final inspection approved stickers on the backside. If occupancy occurs prior to the inspections being approved daily citations will be issued with no further notice being given. 17. All site grading must be done in accordance with the approved drainage plan on file in the public works office, 3rd floor.