HomeMy WebLinkAbout0103031-BuildingOSHKOSH
ON THE WATER
,Job Address 3213 BELLFIELD DR
Designer
Category
CITY OF OSHKOSH No 103031
BUILDING PERMIT -APPLICATION AND RECORD
Owner CREATIVE CUSTOM HOMES Create Date 06/27/2003
Contractor CREATrVE CUSTOM HOMES, INC
110 - New Single Family
· Building (~ Sign (~ Canopy (~ Fence
Type
Zoning R-1 Class of Const: 8
Unfinished/Basement 1117 Sq. Ft. Rooms 7 Height
Finished/Living 1730 Sq. Ft. Bedrooms 3 Stories 2
Garage 422 Sq. Ft. Baths 3
Foundation · Poured Concrete O Floating Slab (~) Pier (~ Other
C) concrete Block (~ Post (~ Treated Wood
Occupancy Permit Required Flood Plain No
Park Dedication Required # Dwelling Units I
Raze
Plan
25 Ft.
Size IRRG
[] Projection
Canopies 0
Signs 0
Height Permit Not Required
# Structures 1
Use/Nature
of Work
NSFR/ 2 Stow with attached 2 car garage and 12' x 12' patio. Driveway will be 18' wide.
HVAC Contractor
Electric Contractor
Fees: Valuation
Issued By: ~
MARTENS HEATING & COOLING
VAN ERT ELECTRIC
$112,000.00 Plan Approval
$75.00 Permit Fee Paid
[] Permit Voided
Plumbing Contractor HANSON QUALITY PLUMBING
$416.00 Park Dedication $100.00
Date 07/23/2003 Final/O.P. 00/00/0000
In the perforrganco of this work I agra. P..!;o perform all work pursuant to rules governing the described construction.
Signature'~ ~/'~JJ ~_¢~.__~, Date ~'~=~'~X
Address 1087VELP AVE GREEN BAY WI 54303 - 0000 Telephone Number 819-2655
To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
OSHKOSH
ON THE WATER
GRADE STAKE FORM
Name CREATIVE CUSTOM HOMES Address
Lot 42 Block
Subdivision VILLAGE GREEN Zone
Street Number Lot Dimensions
Building Grade Elevation Stakes Set At Site 06/30/2003 Set By
3213 BELLFIELD DR
D.W.G. BK -590, P-10
Grade Stake Number 6974
Create Date 06/27/2003
Sidewalk Existing
Ward
Department of Public Works
I, the undersigned, owner or agent of the above described property agree to have the grade established before excavation
has commenced. ¢~~~~
Wisconsin'Departm~nt of Industry,
Labor and Human Relations
Safety and Buildings Division
P.O. Box 2509
Madison, WI 53701-2509
Wisconsin Statues 101.63, 101.73
[] Constr
Owner's Name
CREATIVE CUSTOM HOMES
Contractor: [] Con[~ Elec[] HVAC L~ PIbg
CREATIVE CUSTOM HOMES, INC
Contractor: ~ Con ~J Elec ~J HVAC~J PIbg
VAN ERT ELECTRIC
Contractor: ~J Con L~J ElecL~J HVAC LJ PIb[
~IARTENS HEATING & COOLING
Contractor:~ Con ~J Elec~J HVAC~J Plbg
HANSON QUALITY PLUMBING
Building Address
3213 BELLFIELD DR
WISCONSIN UNIFORM Application No.
BUILDING PERMIT 0103031
APPLICATION Parcel No.
[] HVAC [] Elec [] Plbg [] Erosion [] Other:
Mailing Address
1087 VELP AVE
Telephone No.
GREEN BAY WI 54303 - 0000
Lic/Cert # Mailing Address Telephone No.
679085 1087 VELP AVE GREEN BAY WI 54303 - 0 819-2655
. Lic/Cer~ # Mailing Address Telephone No.
170921 2000 PROGRESS WAY KAUKUANA WI 54130 -0 920-766-3888
Lic/CeA # Mailing Address Telephone No.
;8831 P.O. BOX 106 WAUKAU WI 54980 -106 (920) 685-0111
Mailing Address
550 N BLUEMOUND RD
iLic/Cert # Telephone NO.
APPLETON WI 54914 -0 730-0205
Sq. ft. Subdivision Name 1/4, 1/4,SectiOnLot No. ,T N,RBiock No. E(or)W
V LLAGE GREEN 42
Zoning District(s)
Zoning Permit No. Front Rear Left Right
New [] Repair Single Family
Alteration Two Family
Addition [] Raze Garage
[] Move ~ Other (print):
Other:
Site Constructed
Unfinished Manufactured
Basement 1117 Sq. ft.
Living Area 1730 Sq. ff. 1-Story
[] 2-Story
Garage 422 Sq. fti [] Other
Forced Air Furnace
Size: [] Fuel
Sen/ice: [] Heat Pump Space Htg
Overhead ~ Boiler Water Htg
Underground Central Air Conditioning unit will have 3 kilowatt or
Other more installed electric space heatin
Concrete
Masonry Infiltration centrol option is: [] Full sealing
Sewer of joints. [] Blower door test. [] Exterior
Treated Wood [] Municipal air infiltration barrier.
Other ~ Septic
Permit No. Envelope 28719 BTU/HR
[] Seasonal
Infiltration 23822 BTU/HR
Permanent [] Municipal Utility
[] Plus Basement Other ~ Pdvate On-Site Well $133,000.00
The applicant agrees to comply with all applicable codes, statues and ordinances and with the conditions of this permit, understands that the issuance of
the permit creates no legal liability, express or imj;)lied, on the De.t~rtment or munJcipality; and certifies that all the above information is accurate.
'P..CA.T'S S .ATURE .ATE
APPROVAL CONDITIONS /~s permit is issued pursuant to the following conditions. Failure to comply may result in suspension or
revocation of this permit or other penalty
SEE "STANDARD CONDITIONS OF APPROVAL" SHEET
[] Town [] Village [] City [] County State of: Municipality Number of Dwelling Location:
CityOf Oshkosh 7 0 - 2 6 6
Plan Review $75.00 Construction
HVAC Name JOHN ZARATE
Inspection E~ectrical
Wis. Permit Seal $30.00 Plumbing Date 6/27/03
Other Erosion
Total $105.00 292155 Certi No. 70330
SBD-5823 (R. 07/92)
OSHKOSH
ON THE WATER
,Job Address 3213 BELLFIELD DR
Name CREATIVE CUSTOM HOMES
Address 1087 VELP AVE
Subdivision VILLAGE GREEN
Building Permit Number
Number of Dwelling Units
Fee Required
Owner's Signature ~
Inspector's Signature
PARKLAND DEDICATION FEE COLLECTION RECORD
Date 07/23/2003
GREEN BAY
Lot 42
0103031
1
$100.00
WI 54303
Number of Structures 1
Fee Paid
Date
Date
ro~'
LOT
LOT
d Grode et Home
185o.51
House
House
Ground Grade at Home
1850.51
%
~(
Garage
Grade at Ham
[852.81
House
rage
'NO ONE GETS YOU MORE
THAN THE NEW HOME STORE"
N
SC. dLE: 1" '= 20'
Garage
-Site Plan-
Village Green-Lot 42
City of Oshkosh,
Winnebago County .i'u,~16, 2003
CITY OF OSHKOSH
Project Address
Permit #
Please read the following information and sign at the bottom to acknowledge that you have read
and agree to comply with these conditions.
All habitable rooms must be provided with 8% light and 3.5% ventilation. Bedrooms
located on the second floor or below ground level must be provided with egress windows
in addition to the light and ventilation requirements. Basement windows are also
required to have window well areas in accordance with ILHR 21.03.
Garage spaces shall be separated from the dwelling unit in accordance with ILHR 21:08.
The door and frame assembly between the dwelling unit and an attached garage shall be
labeled by an independent testing a~encv as having a minimum fire-resistive rating of 20
minutes. Ali drywall joints are required to be taped/sealed unless the joints are fitted so
that the gap is no more than a dimes thickness (1/20-inch) 0~nd backed by solid wood or
drywall with the joints staggered.
All penetrations in exterior walls must be sealed prior to the insulation inspection. This
includes holes in the top and bottom plates, gaps around heating ducts, and holes in the
return air spaces.
Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke
detectors are required to be hardwired and intereounected.
Hydromassage tubs are required to have an access panel to motor. The access panel must
be accessible without removing the finish of the house.
All overfram~ng must be designed by the truss manufacturer, according to standards set
by the truss plate institute, or structural calculations must be provided prior to the rough
building inspection.
Truss plans must be submitted and approved prior to framing the roof.
Truss plans including the miss layout must be provided on site at the rough building
inspection. In addition to the truss plans, microlam calculations must be provided an site
at the rough building inspection for all microlams with point loads on them.
Calculations must be provided for all cantilex/ered flobrs with point loads. Floor trusses
and TJI'S must be designed for the cantilevered areas.
10.
The property owner and applicant is responsible for compliance with ILHR 21.125
(Erosion Control). When installing access drives, a minimum of 2"-3" diameter stone is
required in addition to a minimum of 6" depth, 30'-50' length, and 14'-20' width. Erosion
control measures must be maintained until the lawn is established.
11
All storm sewer inlets must be protected with approved erosion control devices. Tracking
(i.e. sediment) must be removed from the street at the end of each workday. Repair any
siltation or erosion damage to adjoining surfaces and drainageways resulting fi:om land
development or disturbing activities.
12.
The building placard must be posted on site at all times. Once the rough framing is up
the placard must be posted on the patio door or on a kitchen window. If the placard is not
present at any inspection, stop work orders will be posted. Additional placards can be
obtained through our depamnent if the cards are misplaced.
13.
All mechanicals must be roughed in prior to requesting the rough building inspection. If
on the inspection the mechanicals are not roughed in, the inspection will fail and a $I00
re-inspection fee will be charged.
14.
Attached is a copy of the final inspection checklist. At the fmal inspection all items on
this list must be completed to avoid the $100 re-inspection fee per inspection.
15.
When requesting final inspections please note that a minimum of 2 days notice is needed
from the time the inspection is ready. Furniture is only allowed to be placed in the center
of the garage floor and a miniinum 6f~i~3, ]ptith~vay ifl~i~t b~ ~fok)ided~around~the Walls of
the garage. At the final inspection no furniture or personal belongings are allowed in the
house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in
place due to the electrical inspector needing to look at the power serving the appliances.
A 6' stepladder must be on site at the final inspection to provide access to the attic.
16.
The building placard must remain on the patio door or on a kitchen window until
occupancy is approved. Occupancy is not allowed prior to the placard having all of the
final inspection approved stickers on the backside. If occupancy occurs prior to the
inspections being approved daily citations will be issued with no further notice being
given.
17. All site grading must be done in accordance with the approved drainage plan on file in the
public works office, 3rd floor.