Loading...
HomeMy WebLinkAboutLetter (Fire Pump Control) Oi/28/2000 15:25 FAS 8475088258 L'�18AVBR �001 —.� 333 Pfingslen Rwd ' NoMbook,Illinoisfi00624W6 �ea�l z�zaeoo �� Underwriters Laboratories lnc. u, F�No i��,z�2�B,z9 MCI Mail No.25a-]313 CaMe ULINC NORTHBRODK,IL TckR No.850250.]]d3 April 26, 2000 Meffon Inc Ann: Mr. Russ Mderson 1505 W. Third Avenue Dtnvcr,CO 80223 Our Refereuce: File E�d357,Project OONKI8104 SubjecC Evaluetion of Metron model M300d25-460C Fire Pump Controller Dear Mr. Andersoa: At your reques[,we conducud an investigation of the subject fi¢pump co�troller installed at: Miles Kimball Co. 2155 S.Oakwood Rd. Oehkosh,WI The purpose of Ihe investiga[ion was m evaluute modificatio�s roade to fire pump controller model M300-125-460C in order for it ro become model M300-150-460C. According to the infortnation you provided,tl�e following modificatSons were made� 1. Contnctor. The contacror was changed&om model LCIF185, rated 185 A,to modei LC1F265,rnted 265 A. 2. Current Tcansformers: Existing cutrent transfo�mers with ratios of 800'S were subsliruted wi[h new curzen[transfo�mers having ratios of UO'S. 3. Wire: T6e wire connecting t6e isolating switch,circuit breaker mid contactor was chunged from 1 AWG to I/0 AWG. 4. Overc�urent Monitoring: The setting of the overcwrcnt monitor w¢s changed from 0.98[0 0 75. 5. Main Na�neplate: The main nameplate waz exchanged[o reflect the new horsepower rating of 150 Hp(instead of 125). We ha�e detetmined Wa[dfe subject device does comply with our mquirements as ihe modifcations made reflea the cunent consttuction of fire pump controller model M300- 150-460C as dcscribed in[he UL File Ex2357 Volume 1 Section 5. Please note lltat the 04/28/2000 15:25 FA% 8475088258 � OIBANBA �002 MMan F£P File Ex2i57 Projttt OONK1610G 26 Apri1.2000 Page 2 of 2 same isolating switch end circuit bceaker is used in both models M300-150-460C and M300-125-460C. If the Authoriry Having Jurisdiction concurs,we feel a field visitation would not be required since the originril UL Lisri�g Mazk was not modified and is sciU valid based o��he modifications made. If you have any questions or commrncs, or if we can be of further service,pleasc do not besita[e to con[act us. Thank you for your intesst u�UL's services. Sincercly, eviewed by, ���'�"C�`C/ Tim Lueck(ext.42082) ovacik('ent. 42972) Project Engineer Assocfate Man?ging Engineer Confoimity Assessmeat Services Conformiry Assessmeat Services Dcpartment 301 SANBK Depaztment 30�18ANBK TimoUry.W.Luwk@us.ulcom ]ohn.R.Kovacik@us.ul.com I cc: City of Oshkosh,Wisconsin � ptm: Inspection Dcpt-,Mr.Kevin Brenner ............. .. _....... _. ..... 215 Church Avenue Osltkosh,WI 54903-I130