HomeMy WebLinkAbout0103245-BuildingOSHKOSH
ON THE WATER
,lob Address 1340 JUDY LEE CT
No 103245
CITY OF OSHKOSH
BUILDING PERMIT -APPLICATION AND RECORD
Owner CC & R WOOD PRODUCTS
Designer Contractor CC & R WOOD PRODUCTS
Category 110 - New Single Family Plan E1-091-0703R
Type · Building (~ Sign (~ Canopy {~ Fence (~ Raze
Zoning R-1 Class of Const: 8 Size IRRG
Unfinished/Basement 1164 Sq. Ft. Rooms 7 Height 26 Ft. [] Projection
Finished/Living 2048 Sq. Ft. Bedrooms 4 Stories 2 Canopies
Garage 737 Sq. Ft. Baths 3 Signs
Foundation · Pound Concrete (~) Floating Slab (~) Pier O Other
(~ Concrete Block (~ Post (~) Treated Wood
Occupancy Permit Required Flood Plain No Height Permit Not Required
Park Dedication Required # Dwelling Units 1 # Structures I
Create Date 07/31/2003
Use/Nature NSFR/ Single family 2 story, 3 car attached garage and a12' x16' patio. Driveway shall not exceed 24' wide at the front property line.
of Work
HVAC Contractor MCM AIR INC
Electric Contractor CUMINGS ELECTRIC
Plumbing Contractor O'NEILL ENTERPRISE INC
Fees: Valuation
Issued By:
$153,000.00 Plan Approval
$75.00 Permit Fee Paid
$539.00 Park Dedication $100.00
Date 08/01/2003 Final/O.P. 00/00/0000
In the pe~
Signature~'~ ~
Address 1645
/ [] Permit VoidedI
swor I agr o a ork pursuantto les governing thedescdbed construction.
Date
~.RNARD DR ',.~MRO WI ~963 - 0000 Telephone Number
920-685-5085
To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
OSHKOSH
ON THE WATER
Name CC & R WOOD PRODUCTS
Lot 212
Subdivision 4th add't Westleigh Farms
Street Number
GRADE STAKE FORM
Address 1340 JUDY LEE CT
Block
Zone
Lot Dimensions
Building Grade Elevation Stakes Set At Site 07/15/2003
Grade Stake Number 6989
Create Date 07/15/2003
L__ Sidewalk Existing
Ward
Set By D.W.G, EXISTING SIDEWALK AT BOTH
I, the undersigned, owner or agent of the above described property agree to hav.9-~e
has commenced.
/~,'~
Departmept of Public Works
r-"~'~tablishedd r~ore excavation/
Wisconsin Department of Industry,
Labor and Human Relations
Safety and Buildings Division
P.O. Box 2509
Madison, WI 53701-2509
Wisconsin Statues 101.63, 101.73
CC & R WOOD PRODUCTS
Contractor: [] Conl~ Elec~]
CC & R WOOD PRODUCTS
Contractor:
CUMINGS ELECTRIC
Contractor:
Contractor: LJ Con
O'NEILL ENTERPRISE ]NC
Building Address
1340 JUDY LEE CT
Lot Area
WISCONSIN UNIFORM ,Application No.
BUILDING PERMIT 0103245
APPLICATION Parca~ No.
Constr [] HVAC [] Elec [] Plbg [] Erosion [] Other:
Mailing Address
1645 BARNARD DR
OMRO WI 54963 - 0000
Mailing Address
1645 BARNARD DR
OMRO Wi 54963- 0
Telephone No.
Telephone No.
920-685-5085
Mailing Address
PO BOX749 1414 COUNTY RD JJ
Telephone No.
NEENAH WI 54957 - 749 231-5946
Telephone No.
WINNECONNIW154986 -9780 (920)582-4402
Telephone No.
PICKETT WI 54964 -0 428-4700 589-:
Mailing Address
6122 COUNTY ROAD M
Mailing Address
N
1/4,
1/4,Section ,T N,R E(or)W
Subdivision Name
4th add't Westleigh Farms
Lot No, ; Block No.
212
Zoning District(s)
Zoning Permit NO.
Front Rear Left Right
New [] Repair Single Family Entrance Panel
I[]~Alteration [~] Raze Two Family
Addition Garage
[] Move Other (print): Overhead
[] Other; Underground
Unfinished
Basement 1164
Living Area 2048 Sq. ft. 1-Story
[] 2-Story
Garage 737 Sq. ft. ~
Other
Site Constructed
Manufactured
Masonry
Traa~d Wood
~]Other
PlUS Basement
The applicant agrees to comply with a
the permit creates n,
APPLICANT'S
APPROVAL CONDITIONS
SEE "STANARD CONDITIONS
tion of this permit or (
Forced Air Furnace
[] Radiant Baseboa~
[] Heat Pump
Boiler
Central Air Conditioning
Other
Sewer
~ Municipal
~ Septic
Permit No.
Fuel
Space Htg
Water Ht,g
unit will have 3 kilowatt or
more installed electric space heating equip.~
Infiltration control option is: [] Full sealing
of joints. [] Blower door test. [] Exterior
a r nfl trat on barder.
$172,000.00
certifies that all the above informatio~ is accurate.
DATE $16NED ~¢~ / / / 0 ,-~
conditions. Failure to comply may result in sl~spensi~n or
[] Town [] Village [] City []
City Of Oshkosh
State of:
Municipality Number of Dwelling Location:
7 0 2 6 6
Name JOHN ZAP, ATE
Date 7/31/03
Cert. No. 70330
Plan Review
Inspection
Wis. Permit Seal
Other
Total
$75.00 Construction
HVAC
Electrical
$30.00 Plumbing
Erosion
$105.00
292158
SBD~5823 (R. 07/92)
OSHKOSH
PARKLAND DEDICATION FEE COLLECTION RECORD
ON THE WATER
Job Address 1340 JUDY LEE CT
Name
Address 1645 BARNARD DR
Subdivision
Building Permit Number 0103245
Number of Dwelling Units
Fee Required
CC & R WOOD PRODUCTS
Lot 212
Owner's Signature
Inspector's Signature
4th add't Westleigh Farms
OMRO
1
Date 08/01/2003
WI 54963
Number of Structures 1
Date (~/j /(~
Date
CITY OF OSHKOSH
STANDARD CONDITIONS OF APPROVAL
Project Address '~'~0 3D~ ~-~-'~ Permit #
Please read the following information and sign at the bottom to acknowledge that you have read
and agree to comply with these conditions.
All habitable rooms must be provided With 8% light and 3.5% ventilation. Bedrooms
located on the second floor or below ground level must be provided with egress windows
in addition to the light and ventilation requirements. Basement windows are also
required to have window well areas in accordance with ILHR 21.03.
Garage spaces shall be separated from the dwelling unit in accordance With ILHR 21.08.'
The door and frame assembly between the dwelling unit and an attached garage shall be
labeled by an independent testin~ a~encv as having a minimum fire-resistive rating of 20
minutes. All drywall joints are required to be taped/sealed unless the joints are fitted so
that fire gap is no more than a dimes thickness (1/20-inch) and backed'b3~ ~olid wood ~or
drywall with the joints staggered.
All penetrations in exterior walls must be sealed prior to the insulation inspection. This
includes holes in the mp and bottom plates, gaps around heating ducts, and holes in the
return air spaces.
Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke
detectors are required to be hardwired and intemonnected.
Hydromassage tubs are required to have an access panel to motor. The access panel must
be accessible without removing the finish of the house.
All overframing must be designed by the truss manufacturer, according to standards set
by the truss plate institute, or structural calculations must be provided prior to the rough
building inspection.
7. Truss plans must be submitted and approved prior to framing the roof.
Truss plans including the truss layout must be provided on site at the rough building
inspection. In addition to the tress plans, microlam calculations must be provided on site
at the rough building inspection for all microlams with point loads on them.
Calculations must be provided for all cantilevered floors with point loads. Floor tresses
and TJI's must be designed for the cantilevered areas.
10. The property owner and applicant is responsible for compliance with ILHR 21.125
(Erosion Control). When installing access drives, a minimmn of 2"-Y' diameter stone is
required in addition to a minimum of 6" depth, 30~-50' length, and 14'-20' width. Erosion
control measures must be maintained until the lawn is established.
11.
All storm sewer inlets must be protected with approved erosion control devices. Tracking
(i.e. sediment) must be removed from the street at the end of each workday. Repair any
siltation or erosion damage to adjoining surfaces and drainageways resulting from land
development or disturbing activities.
12.
The building placard must be posted on site at ail times. Once the rough framing is up
the placard must be posted on the patio door or on a kitchen window. If the placard is not
present at any inspection, stop work orders will be posted. Additional placards can be
obtained through our department if the cards are misplaced.
13.
Ail mechanicals must be roughed in prior to requesting the rough building inspection. If
on the inspection the mechanicals are not roughed in, the inspection will fail and a $100
re-inspection fee will be charged.
14.
Attached is a copy of the final inspection checklist. At the final inspection all items on
this list must be completed to avoid the $100 re-inspection fee per inspection.
15.
When requesting final inspections please note that a minimum of 2 days notice is needed
from the time the inspection is ready. Furniture is only allowed to be placed in the center
of the garage floor and a minimum ora 3' pathway must be provided around the walls of
the garage. At the final inspection no furniture or personal belongings are allowed in the
house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in
place due to the electrical inspector needing to look at the power serving the appliances.
A 6' stepladder must be on site at the final inspection to provide access to the attic.
16.
The building placard must remain on the patio door or on a kitchen window until
occupancy is approved. Occupancy is not allowed prior to the placard having all of the
final inspection approved stickers on the backside. If occupancy occurs prior to the
inspections being approved daily citations will be issued with no further notice being
given.
17.
All site grading must be done in accordance with the approved drainage plan on file in the
NOI1140t/ Hlb ZlZ lOl 121f100 33~ Jl0t1t' - 1~d
'SNOILS3t10 JINN tlOti ~
'3'~lIOQlS 3Hi .i0 t~1aGY18 T/J0~1 OtM '~t'tt a'N"i1 'SLt'tL 't~'1t'1'1 tx19iD0
Flo ssv~~JW FIINA a~o3 15th~s S'13N~1~ "o ~ 11115 ~ ti~8~1~111q AN019Oa3
a3dorw au. ~ s,~a~raUioo ~u ~ ~
V
N
N
--i
O
n
v
m
/'
„0 .Oti
.~
,OZ L
~N
'- mr1
~ ,9Z
v
,6l
_ 3NIl lOl ~ XbYV ,1~Z
~ ~'' 3N210 SS300b l3J\`d2i0
~ ~ 3JV21dJ ~ aN'd 1.dM3Alba
o
N ,Z ~
I
O
s
N
`°- 3SnOH o +9 ~
~ ~ ~,
= ca Z
S:OL-8t+OZ-Z~N1fid ~ ~
rn
o ,L~ ~
1
w
s
,OZ l
„0 SS «0 .SZ
`c~
a
r
m
n
O
C
~~~
~21~
~ :~~