HomeMy WebLinkAboutItem IIPLAN COMMISSION STAFF REPORT NOVEMBER 3, 2020
ITEM II: PUBLIC HEARING: CONDITIONAL USE PERMIT FOR A GROUP DEVELOPMENT AT THE 2600 BLOCK OF WITZEL AVENUE (THE WIT DEVELOPMENT)
GENERAL INFORMATION
Applicant/Owner: Moorhead Barr Properties, LLC/Steve Moorhead
Action(s) Requested:
The applicant requests approval of a Conditional Use Permit for a Group Development consisting of twelve two-family structures.
Applicable Ordinance Provisions:
Conditional Use Permit standards are found in Section 30-382 of the Zoning Ordinance.
Property Location and Type:
The subject area consists of one parcel approximately 18.5 acres in size, located at the south 2600 Block of Witzel. The site was previously owned by Ascension Hospital as a future
expansion area but was never used. The site is vacant and is proposed to have a similar character to the multi-family developments to the north and east. The development across Witzel
Avenue north the surrounding area includes a multi-family development, duplex, and single family properties. The subject site abuts a multi-family property to the east. The City boundary
runs along the west edge of the subject site. The subject site is adjacent to single-family properties in the Town of Algoma on its western edge. The subject site abuts the Mercy Medical
Center on its south edge. The Comprehensive Land Use Plan 2040 recommends this area for Medium and High Density Residential.
The Common Council recently approved a Comprehensive Land Use Plan Map Amendment from light density residential to medium and high density residential at the Council’s June 9th, 2020
meeting. The Council approved a zone change from SR-5 to MR-12 residential concurrently with the Comp Plan Amendment at the same meeting. The Plan Commission reviewed the Comp Plan
Amendment and Zone Change and recommended approval of both at the April 21st, 2020 Plan Commission meeting. Prior to the April 21st Plan Commission review, the petitioner held a neighborhood
meeting with the surrounding property owners on April 3rd to obtain their input on the proposal to redevelop the site as a multi-family development. The neighbors’ main concerns were
related to potential storm water runoff, provided greenspace, and potential views from the adjoining properties. Staff and the developers informed the neighbors that the subject site
would have to be in compliance with the storm water, greenspace, and bufferyard standards per City ordinances.
The petitioner now seeks to move forward on plans to develop the site with a multi-family development. The zoning ordinance requires a conditional use permit for any new development
of three or more buildings. Therefore, the conditional use permit is the final step in the approval process for the site.
Subject Site
Existing Land Use
Zoning
Vacant/Undeveloped
Multi-family Residential-12 (MR-12)
Adjacent Land Use and Zoning
Existing Uses
Zoning
North
Multi-family, Duplex, Single-family
Multi-family Residential-12 (MR-12), Duplex Residential-6 (DR-6), Single-family Residential-5 (SR-5)
South
Mercy Medical Center
Institutional-Planned Development (I-PD)
East
Multi-family Residential
Multi-family Residential-12 (MR-12)
West
Single-family Residential (Town of Algoma)
County Zoning (R-2)
Comprehensive Plan Land Use Recommendation
Land Use
2040 Land Use Recommendation
Medium and High Density Residential
ANALYSIS
Use
The petitioner seeks to develop the site with twelve two-story multi-family buildings each including twelve living units, for a total of 144 two-bedroom units. The site will also include
four detached garage buildings and surface parking. The center of the site will include a large retention pond, clubhouse, and green space. The orientation of the multi-family buildings
around the perimeter of the site is intended to allow for efficient wayfinding and site circulation. The site would include three refuse enclosures each with three 8-yard dumpsters
for tenant use. The conditional use permit process allows such group developments of three or more principal buildings on a subject parcel. The dwelling unit density is less than some
of the surrounding development. This proposed development equates to 7.78 units per acre. The multi-family development to the east equates to 13.9 units per acre, while the multi-family
development to the north equates to 13.22 units per acre. The MR-12 zoning district allows up to 12 dwelling units per acre so the proposed development is under the maximum allowed
density for the site.
Site Design/Access
/
The above site plan shows the petitioner’s proposal for the site. Witzel Avenue is located to the north of the site (top of the plan) and Mercy Medical Center is to the south. The
single family homes in the Town of Algoma are located to the west.
The development site consists of an existing 18.5 acre rectangular-shaped parcel. The proposed centrally-oriented plan places twelve multi-family structures around a central space
which includes a large clubhouse, retention pond, and community space. The twelve proposed multi-family structures are very similar to one another in appearance. The multi-family structures
would each include two stories and twelve 2-bedroom living units with attached garages. These structures are evenly distributed throughout the site. Associated surface parking and
four
detached garage buildings (44 enclosed parking spaces total) would serve the development. The site would include three refuse enclosures. All of the proposed buildings meet the MR-12
zoning district’s principal structure setbacks. They are located between 22 and 28 feet from the nearest lot lines. Their separations range between 60.75 feet and 61 feet except for
the southernmost buildings which are 54 feet away from the detached garages on the south edge of the site. The total proposed impervious surface coverage is 53.8 percent of the lot
area. Green space would consist of the remaining 46.2 percent of the lot. This is compliant with the 60 percent maximum impervious surface ratio for an MR-12 parcel.
Access to the site would consist of two access drives leading into the site from Witzel Avenue. These drive aisles would run longitudinally through the site and provide access to each
of the 12 buildings, outdoor area and clubhouse, detached garages, and associated surface parking stalls. Based on the calculations provided and staff calculations the number of striped
and enclosed spaces is less than the code minimum required (see below table). The proposed number of spaces is 5 less than the code minimum when counting the number of living units
and the clubhouse area. The petitioner will have to add the required five parking spaces during the Site Plan Review Process. Staff will work with the petitioner to finalize the site
plan.
/
The zoning ordinance has outdoor recreational space requirements for multi-family uses. The amount of space required is based on the number of bedrooms in the development. The proposal
significantly exceeds the amount of open space required based on the number of bedrooms provided (see table below).
/
Landscaping
/
/
The petitioner has submitted a landscaping plan and point totals for the site (above). They have breakdowns of required landscaping points based on the amount of improvements (buildings
and paved areas) they have proposed for the site. Based on the required and proposed point totals, the proposal meets the ordinance minimums for landscaping on the site. A bufferyard
of 0.2 opacity is required for the west property line due to the adjacent single-family homes. The petitioner will need to install a 6 foot tall solid fence along the west property
line to fulfill this requirement. The petitioner’s proposed point totals for building foundation, paved area, street frontage, and yard landscaping meet the point total requirements.
The landscaping schedule includes Goldmound (Japanese) Spirea, which is a prohibited plant. The petitioner will need to revise the plan and exchange the prohibited plant species for
alternative code compliant options. The petitioner also has Autumn Blaze Maples and Sugar Maples which are on the “Use Sparingly” plant list. For site plan review staff will require
an updated landscaping schedule that shows which plant species are devoted to which landscaping categories. The schedule will also need to show point totals for each plant species.
Staff recommends as a condition of approval a requirement that the applicant submit compliant fencing details and a revised code compliant landscaping plan and schedule for Site Plan
Review.
Lighting
The applicant has submitted a photometric plan showing light levels for all the paved areas on-site. The plan as proposed is deficient in a number of areas especially the drive areas
between buildings (see photometric plan below). It appears that one of the access drives may also be deficient in lighting based on the photometric information provided. The petitioner
has not submitted mounting height information or details of the proposed light fixtures for the site. Staff will require the light fixture information and a revised, code compliant
photometric plan for Site Plan Review.
/
The above photometric plan shows areas of deficient lighting. Areas in red are beneath the 0.4 footcandle code minimum for drive areas. North is at the top of the plan.
Signage
The proposal includes a freestanding monument sign with associated landscaping at the north end of the site. The sign as shown on the site plan meets the required 25 foot front setback
for the MR-12 parcel. The applicant has not submitted a proof for the sign. The sign will have to meet the area standards prescribed in the Signage section of the zoning ordinance.
No on-building signage proposals were submitted.
Building Facades
/
The above renderings show the proposed multi-family buildings that would occupy the site.
The petitioner has submitted renderings for the proposed multi-family development (see above). These meet the multi-family design standards. They include articulation such as recesses
and projections, balconies, material changes, etc. The building facades as proposed meet code. The petitioner has not submitted elevations for the detached garages or refuse enclosures.
Refuse enclosures must be constructed of solid wood or one or more materials used on the exterior of the principal buildings. Staff will require detached garage elevations and refuse
enclosure details as part of the Site Plan Review Process.
/
The above image shows the proposed clubhouse and swimming pool that would be centrally located on the site plan.
Storm Water Management/Utilities
A large retention pond is proposed in the center of the site. The petitioner has submitted erosion control, drainage, and grading plans. The new development will add a significant
amount of impervious surface area to the site. Therefore, the Department of Public Works has stated that a full site plan review and approval will be required through the Site Plan
Review Process.
Conclusion
Staff is in support of the proposed multi-family group development as the use is consistent with the surrounding multi-family developments in the area. It is consistent with the zoning
and the Comprehensive Plan 2040 land use recommendation of medium/high density residential for the site. Staff would recommend approval as long as the petitioner is willing to meet
the conditions listed previously. These include submission of code compliant fencing details, revised landscaping and photometric plans and information, and refuse enclosure details.
If the proposed development meets code, staff has no concerns.
Upon review, staff is of the opinion the proposed land use is not in conflict with the criteria listed for Conditional Uses and is in support of the development.
FINDINGS/RECOMMENDATION/CONDITIONS
In its review and recommendation to the Common Council on an application for a Conditional Use Permit, staff recommends the Plan Commission make the following findings based on the
criteria established by Chapter 30-382 (F)(3):
Is in harmony with the Comprehensive Plan.
Would not result in a substantial or undue adverse impact on nearby property, the character of the neighborhood, environmental factors, traffic factors, parking, public improvements,
public property or rights-of-way, or other matters affecting the public health, safety, or general welfare.
Maintains the desired consistency of land uses, land use intensities, and land use impacts as related to the environs of the subject property.
The conditional use is located in an area that will be adequately served by, and will not impose an undue burden on, any of the improvements, facilities, utilities or services provided
by public or private agencies serving the subject property.
The potential public benefits outweigh any potential adverse impacts of the proposed conditional use, after taking into consideration the applicant’s proposal and any requirements recommended
by the applicant to ameliorate such impacts.
Staff recommends approval of the Conditional Use Permit for a multi-family group development and to exceed ordinance parking maximums with the findings listed above and following conditions:
Petitioner to submit code compliant fencing details and install a code compliant 6’ tall solid (at least 90% opaque) fence along the west property line.
Petitioner shall submit a revised landscaping plan and schedule with code-compliant species and code-compliant landscaping point totals for Department of Community Development review
as part of the Site Plan Review Process.
Petitioner shall submit a revised, code-compliant photometric plan, light fixture mounting information, and light fixture details to staff for Department of Community Development review
as part of the Site Plan Review Process.
Petitioner to submit detached garage elevations and dumpster enclosure elevations and details to staff for Department of Community Development review as part of the Site Plan Review
Process.