HomeMy WebLinkAbout0103060-Building (remodel sunroom)OSHKOSH
ON THE WATER
.lob.Address 1935 CLIFFVlEW CT
Designer
CITY OF OSHKOSH
BUILDING PERMIT - APPLICATION AND RECORD
Owner JOHN K/LINDA DEDEE
Contractor QUALITY PLUS CONSTRUCTION INC
Category 140 - Interior Remodeling
No 103060
Create Date 07/24/2003
Plan
Type I(~ Building (~ Sign (~ Canopy (~ Fence (~ Raze
Zoning Class of Const: Size
Unfinished/Basement 0 Sq. Ft. Rooms 0 Height 0 Ft. ~J Projection
Finished/Living 0 Sq. Ft. Bedrooms 0 Stories Canopies
Garage 0 Sq. Ft. Baths 0 Signs
Foundation O Poured Concrete ~ Floating Slab ~ Pier ~ Other
~ Concrete Block ~ Post ~ Treated Wood
Occupancy Permit Required Flood Plain Height Permit
Park Dedication # Dwelling Units 0 # Structures 0
Use/Nature SFR/Remodeling the existing sunroom to create a vaulted ceiling. Calculations are req. for the existing header between the house and the
of Work sunroom. Transom windows will be installed on the gable end and a new 6' patio door will be installed to the patio.
HVAC Contractor
Electric Contractor
Fees: Valuation
Issued By:
Plumbing Contractor
$15,000.00 Plan Approval $0.00 Permit Fee Paid
$80.00 Park Dedication $0.00
Date 07/24/2003 Final/O.P. 00/00/0000
Permit Voided
In the performance of this work I agree to perform all work pursuant to rules governing the described construction.
Signature
Date
Agent/Owner
Address W 4205 JEAN ST APPLETON WI 54915 - 0000 Telephone Number 920-734-7898
To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
OSHKOSH
ON THE WATER
Job Address 1935 CLIFFVIEW CT
Designer
Category
Type
Zoning
140 - Interior Remodeling
CITY OF OSHKOSH
BUILDING PERMIT - APPLICATION AND RECORD
Owner JOHN K/LINDA DEDEE
Contractor QUALITY PLUS CONSTRUCTION INC
Plan
· Building (~ Sign (~ Canopy O Fence (~) Raze
Unfinished/Basement 0 Sq. Ft.
Fintahed/Living 0 Sq. Ft.
Garage 0 Sq. Ft.
Foundation · Poured Concrete (~) Floating Slab
(~ Concrete Block O Post
Occupancy Permit Required
Park Dedication
No 103060
Create Date 07/24/2003
Class of Const:
Rooms 0 Height 0 Ft.
Bedrooms 0 Stories
Baths 0
(~ Pier O Other
(~ Treated Wood
Flood Plain Height Permit
# Dwelling Units 0 # Structures 0
Size
[] Projection
Canopies 0
Signs 0
Use/Nature SFR/Remodeling the existing sunroom to create a vaulted ceiling. Calculations are req. for the existing header between the house and
of Work the sunroom. Transom windows will be instslled on the gable end and a new 6' patio door will be installed to the patio.
HVAC Contractor
Electric Contractor
Fees: Valuati~¥ ~n
Issued By k~'~
$15,000.00 Plan Approval
Plumbing Contractor
$0.00 Permit Fee Paid $80.00 Park Dedication $0.00
Date 07/24/2003 Final/O.P. 00/00/0000
[] Permit Voided
In the perform~e_of th~j~, agree~,~ e~.,~ work pursuant to rules governing the described construction.
Address W 4205 JEAN ST APPLETON WI 54915 - 0000 Telephone Number 920-734-7898
To schedule inspections please call the inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
'7' X~'
/&'
w'lNb(3~'
"r R,4 /g,S t/ /vI
For4 N£~ ,~,4FT'ERS
WINI)~v¢'
~ a.d'vson ofTJ int~rn~ti'6n:al" ".'~ 7. '. -:, ' ' ' ,., ' ' ' ', , ' ' ::'
~'~'.~ A DMgion of L~n~ga Corporation
Roger Krause
Outside Salee Representative
Bus. (920)
Bus. (920) 779-4671
Line Item ~..
0001
Location:
RO Size
9' 6 3/8" W x 8' 4 7/8" H
1
2
6
3
7
4
Scale = 1:21.5
6x6 ~-
3
6.00
LOADING (ps0
TCLL 30,0
TCDL 7.0
BOLL 0.0
BCOL 10.0
I
SPACING 1-0-0 ~ CSI
Plates Increase 1.15 [ TC 0.71
Lumberlncrease 1.15 84; 0.61
RepStress [hcr NO WB 0.03
Code WISC/ANSI95 (Matrix)
LUMBER
TOP CHORD 2 X 8 SYP 2250F 1 ,gE
BeT CHORD 2 X 4 SPF 2100F 1
WEBS 2 X 8 SPF No.2
REACTIONS(lb/size) 1 =1168/0-3-6, 5=1168/0-3-6 Max Horz 1 =-63(Icad case 2)
Max Uplift1 =-182(Icad case 4), 5=-182(toad case
FORCES (lb) - First Load Case Only
TOP CHORD 1-2=-471, 2-3=-5120, 3-4=-5120, 4-5=-471
BeT CHORD 2-6=5229, 4-6=5229
WEBS 3'6=444
NOTBS
PLATES GRIP
MI]20 197/'144
Weight: 103 lb
BRACING
TOP CHORD Sheathed or 6-0-0 cc pedins,
BeT CHORD Rigid ceiling directly applied or 10-0-0 CC bracing.
1 ) This truss has been checked for unbalanced loading conditions,
g) This truss has been designed for [he wind loads generated by 80 mph winds at 25 ff above ground level, using 5.0 pal top chord dead Icad and 5.0 psf bottom
chord dead toad, 100 mi from hurricane oceactine, on an occupancy
ASCE 7-93 per WISC/ANS195 If end verdca]s or cantilevers exist, they are exposed to w~nd, If porches ex[st, they are not exposed to wind. Tt~e lumber DeL
increase is 1.33, and the plate grip increase is 1.33
3) Bearing at joint(s) 1,5 considers parallel to grain value using ANSgTPI 1-1995 angle to grain formula. Building designer should verify capacity of bearing
4) Provide mechanical connection (by others) of truss to beadng plate capable Of withstanding 182 lb uplift at joint 1 end 182 lb uplift at joint 5.
5) This truss has been designed with ANSIfTPI 1-1995 cdteda.
6) Load case(s) 1,2, 3, 4, 5, 6 has been modified. Building designer must review loads to redly that they are correct for the intended use of this truss.
7) 2-ply truss to be connected together w~th 0.131"x3" Nails as follows:
Top chords connected as fei]owe: 2 X 8 - 2 rows at 0-5~3 0c.
Bottom chords connected as follows: 2 X 4 * I row at 0-9-6
Webs connected as folloWS: 2 X 8 - 2 rows at 0-9-0 cc,
8) Special hanger(s) or connection(s) required to support concentrated Icad(s) 1762 5lb down and 274,51b up at 6-3-0 on top chord. Design for unspadfied
connection(s) is delegated to the building designer,
LOAD CASE(S)
1) Regular: Lumber Increase=l,15, Plate Increase=1.15
Uniform Loads (pi0
Concentrated Loads (lb)
Ve~t: 3=-1762.5
2) Wind Left: Lumber Idcrease=1,33, Prate Increase=1.33
Uniform Loads (pg)
Veal: 2-4=-5,0, 1-2=-3,4, 2-3=1.6, 3-4=12.3, 4-5~7.3
Horz: 1-3=-6.6, 3-6=17.3
Concentrated Loads {lb)
Job TF r~ss Truss Type
QUALIT-'~* TAIL BEARING
TIMBER BOOTS MTD, Ma ckville, W] 54913, Douglas D Danke
LOAD CASE(S)
Uniform Loads (pd)
Horz: 1-3=-17.3, 3-5=17,3
Concentrated Loads (lb)
1st unbalanced Regular: Lumber Increase=l.15, Plate Increase=1,15
Uniform Lcads {plf)
Vert; 2-4=-10.0, 1-2=-47,0, 2-3=-37,0, 3-4=-7.0, 4-5=-17.0
Concentrated Loads (lb)
Vert; 3=-t 762.5
6) 2nd unbalanced Regular: Lumber Increase=1,15, Plate Increase=1.15
Uniform Loads (piT')
Verb 2-4=-10.0, 1-2=-17,0, 2-3~7.0, 3-4=-37,0, 4-5=-47.0
Concentrated Loads
Verb 3=-1782.5
Qty Ply
4,201 SRI s Nov 16 2000 MiTek Industries, Inc. Wed Jul 23 09:08:43 2003 Page 2
page1 Engine Version: 1.e.12
Ridge Beam
I 3/4" x 9 1/2" 1,9E Microllam® LVL
THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN
CONTROLS FOR THE APPLICATION AND LOADS LIg'rF~-
Member Slope: 6~12 Root Slope6tlZ
All dimensions are horizontal.
~ '12' 6" ~
Product Diagram is Conceptual.
~OADS:
Analysis is for a Header (Flush Beam) Member. Tributary Load Width: 1'
Pdrna~ Load Group - Snow (psf): 30.0 tJve at 115 % duration, 17.0 Dead
Vertical Loads:
Type Class Live Dead Location Application
Uniform(plf) Snow(I.15) 188.0 106.0 0 To 12' 6" Adds To
SUPPORTS:
Input Bearing Vertical Reactions (lbs) Detail
Width Length Live/Dead/U plfftJ'r otal
1 Studwall 3.50" 3.80" 1363/810/0/2172 LI: Blocking
2 Studwall 3.50" 3.50" 1363/810/0/2172 Ll:Blocking
-See TJ SPECIFIER'S / BUILDERS GUIDE for detail(s): LI: Blocking
DESIGN CONTROLS:
Maximum Design Control
Shear (lbs) 2115 -1796 3633
Moment (Ft-Lbs) 6432 6432 6771
Live Load Deft (in) 0.482 0.608
Total Load Deft (in) 0.768 0.8t I
Other
1 P~y I 3/4" 1.9E Microllam~ LVL
I Ply 1 3/4" 1.9E Microllam® LVL
Control Location
Passed (49%) Rt. end Span I under Snow loading
Passed (95%) MID Span 1 under Snow loading
Passed (L/303) MiD Span 1 under Snow loading
Passed (12190) MID Span 1 under Snow loading
-Deflection C~tada: STANDARD(LL:L/240,TL:L/180).
-Bracing(I-u): All compression edges (top and bet[om) must be braced at 2' 8" o/c unless detailed otherwise, proper attachment and positioning of lateral
bracing is required to achieve member stability.
-Design assumes adequate continuous lateral support of the compression edge.
ADDITIONAL NOTES:
-IMPORTANT! The analysis presented is output from software developed by Trds Joist (TJ). TJ warrants the sizing of its products by this software wi[I be
accomplished in accordance with TJ product design edter~a and code accepted design values. The spacifie product application, input design loads, and
stated dimensions have been provided by the software user. This output has not been reviewed by a TJ Assosiate.
- Not all products are readily available. Check with your supplier or TJ technical representative for Product availability.
-THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONLYI PRODUCT SUBSTITUTION VOIDS THiS ANALYSIS.
-Allowable Stress Design methodology was used for Building Code NER analyzing the TJ Distribution product listed above.
PROJECT INFORMATION:
Quality Plus DEDEE Job
OPERATOR INFORMATION:
Mark Piquette
Timber Roots Mackv[lle- UBC #745
W4892 County Road O
Appleton, Wisconaln 64913
Phone: 920-736-1769
Fax : 920-735-1781
mp[quette@hoida.com
TJ-Beam(TM)6.05SeriaINumbe,:7002105471 I 3/4" X 9 1/2" 1,9E Microllam® LVL
Page2 EngineVerslon: 1.5.12 THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN
CONTROLS FOR THE APPLICATION AND LOADS LISTED
^ 12' 2.00"
Vertical Reaction Total (lbs) 2172 2172
Vertical Reaction Live (lbs) 1363 1363
Reqn~ired Bearing Length in 2.92(W) 2.92(W)
Ur~braced Length (in) 32
all spans, LDF = 1.15 , Dead + Floor + Snow
Demig= Shear (lbs)
~ax Shear (lbs)
Meatier Reaction (lbs)
Support Reaction (lbs)
Moment (Ft-Lhs)
Live Deflection (in)
Total Deflection (in)
1796 -1796
2115 -2115
2115 2115
2172 2172
6432
0.482
0.768
Loading on all spans, LDF = 0.90 , Dead Only
Depi~ Shear (lbs) 670 -670
Flax shear (lbs) 788 -788
Meraber Reaction (lbs) 788 788
Su[~port Reaction (lbs) 810 810
Moment (Ft-Lhs) 2398
PROJECT INFORMATION:
Ouality Plus DEDEE Job
OPERATOR INFORMATION:
Mark P[quette
Timber Roots Maokville * UBC #745
W4892 County Road O
Appleton, Wisconsin 54913
Phone; 920-735-1769
Fax ; 920-755-1781
mpiquette@hoida.com
TJ_~eam(TM)S.06SerialNumben7002~6~5 3 112" x 9 1/2" 1.SE TimberStrand® LSL
Page1 En~ineVer~io~: 1.6.44 THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN
CONTROLS FOR THE APPLICATION AND LOADS LISTED
Member Slope: 0/12 Roof Slopeg/12
All dimensions ars horizontal,
Product Diagram is Conceptual.
LOADS:
Analysis is for a Header(Flush Beam) Member. Tributary Load Width: 1'
Primary Load Group - Snow (psf): 30.0 Live at 115 % duration, 15.0 Dead
Vertical Loads:
Type Class Live Dead Location Application
Uniform(pio Snow(1.15) 660.0 330.0 0 To 7' 4" Adds To
Comme~
SUPPORTS:
Input Bearing Vertical Reactions (lbs) Detail
Width Length Llve/Dead/U pliff/Totai
1 Studwall 3.00" 3.0(7' 253011302/013832 LI: Blocking
2 Stud wall 3.00" 3.00" 2530 / 1302 / 0 / 3832 L1: Blocking
-See TJ SPECIFIER'S / BUILDERS GUIDE for detail(s): LI: Blocking
Other
1 Ply 1" x 9 1/2" e-Rim Board®
I Ply 1" x 9 I/2" e-Rim Board®
DESIGN CONTROLS:
Maximum Design Co,roi Control
Shear (Ihs) 3702 -2744 10197 Passed (27%)
Moment (Ft-Lbs) 6555 6555 11598 Passed (57%)
Live Load Deft (in) 0.t24 0.236 Passed (L/684)
Total Load Deft (in) 0.188 0.354 Passed (I./452)
Location
Rt. end Span 1 under Snow loading
MID Span 1 under Snow Ioading
MID Span 1 under Snow loading
MID Span 1 under Snow loading
-Dm3ection Criteria: STANDARD(LL:L/360,TL:LD40).
-Bracing(Lu): Ali compression edges (top and bottom) must be braced at 2' 8" o/c unless detailed otherwise. Proper attachment and positioning of lateral
bracing is required to achieve member stability.
-Design assumes adequate continuous Isteral support of the compression edge.
ADDITIONAL NOTES:
-IMPORTANT! The analysis presen[ed is output fram software developed by Trus Joist ('r J). TJ warrants the sizing of its products by this software will be
accomplished in accordance with TJ product design criteria and code accepted design values. The specific product application, input design loads, and
stated dimensions have been provided by the software user. This output has not been reviewed by a TJ Associate.
-Not all products are readily available. Check with your supplier or TJ technical representative for product availability.
-THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THiS ANALYSIS.
-Allowable Stress Design methodology was used for Building Code BOCA analyzing the TJ Distribution product listed above.
Operator Notes:
2 SHOULDER STUDS
PROJECT INFORMATION:
QUALITY PLUS
DEDEEJOB
OPERATOR INFORMATION:
UNITED BUILDING CENTER
P.O. BOX 9
HIGHWAY 45
GREENVILLE, WISCONSIN 54942
Phone: 920-757-5433
Fax : 920-757-6624
Fage2 EngineVersio~: 1.~D. 44 THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN
CONTROLS FOR THE APPLICATION AND LOADS LISTED
,Load Group: Primary Load Group
7' 1.00"
Max. Vertical Reaction Total (lbs) 3832 3832
Max. Vertical Reaction Live (lbs) 2530 2530
Required Bearing Length in 1.84 (W) 1.84 (W)
Max. Unbraced Length (in) 32
Loading on all spans, LDF = 1.15 , Dead + Floor + Snow
Design Shear (lbs)
Max Shear (lbs)
MeI~ber Reaction (lbs)
Support Reaction (lbs)
~oment (FI-Lbs)
Live Deflection (in)
Total Deflection (in)
2744 -2744
3702 -3702
3702 3702
3832 3832
6555
0.124
0.188
Loading on all spans, LDF - 0.90 , Dead Only
Design Shear (lbs) 932 -932
Hax Shear (lbs) 1258 -1258
~e~ber Reaction (lbs) 1258 1258
Support Reaction (lbs) 1302 1302
~oment (FI-Lbs) 2227
PROJECT INFORMATION:
QUALITY PLUS
DEDEE JOB
Copyright ~ 2003 by Trus Joist, a Weyerhaeuser Business
OPERATOR INFORMATION:
UNITED BUILDING CENTER
P.O. BOX 9
HIGHWAY 45
GREENVILLE, WISCONSIN 54942
Phone: 920-757-5433