HomeMy WebLinkAbout0107734-Plumbing (interior)OSHKOSH
ON THE WATER
.lob Address 2335 HICKORY CT
Contractor O'NEILL ENTERPRISE INC
CITY OF OSHKOSH
PLUMBING PERMIT - APPLICATION AND RECORD
Owner FARO/SERAFINA VITALE
Category 410 - Residential-Interior
No 107734
Create Date 03/17/2004
Plan
Bathtub 2 Shower 1 Ejector/Grind 0 DipWell 0 F Prep Sink 0 Gar Drain 0
Whirlpool 1 Floor Drain 1 Water Softner 0 Drink Ftn 0 Serv Sink 0 Soda Disp 0
Lavatory 4 Lndry Tray 0 LocaIWaste 0 Wait. St. 0 Shamp Sink 0 Coffee Maker 0
Toilet 4 Lndry Stndp 1 ClothesWshr 0 Ice Chest 0 FIr/Wst Sink 0 Int Grease Trap 0
Res. Sink 1 Disposal 1 Bidet 0 Exam Sink 0 Catch Basin 0 Ext Grease Trap 0
Bar Sink 0 Dishwasher 1 Beer Tap 0 SculrySink 0 Wash Ftn 0 RPZValve 0
Water Heater 1 Sump Pump 1 Dent. Oper. 0 Hand Sink 0 Urinal 0 Eye Wash Statn 0
Site Drain 0 Classrm Sink 0 Lab Sink 0 Plaster Sink 0 Standp Rec 0
Roof Drain 0 Breakrm Sink 0 Sterilizer 0 Surgeons Sink 0 Ice Maker 0
Use/Nature NSFR/ Newsingle family
of Work
Size Material Type # Conn. Type
Sanitary Sewer 0
0
0
0
0
Storm Sewer 0
0
0
0
0
Water Service 0
0
0
0
0
Valuation $12,000.00 Plan Approval $0.00 Permit Fees $133.00 ~ Permit Voided
Issued By
Parcel Id #
1526190900
Date 04/28/2004
In the performance of this work, I agree to perform all work pursuant to rules governing the described construction.
While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work
described in this permit application within an easement, the City strongly urges the permit applicant to contact the
easement holder(s) and to secure any necessary approvals before starting such activity.
Signature Date
Agent/Owner
Address 5575 CTY RD N PICKETT WI 54964 - 0000 Telephone Number
920-428-4700 589-2
To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
1214/21/2004
-
j.,
,.~
..
f"
r\
"
PAGE 03
2.~~"\ ~ 1-k.S ,.~
I -11~"~ 3,t I - Ow ,
\ _ WI:.'" !.- ~ l.fl3 ~
P--3~ l-LIW I I. Aw I.S'"'
,-aT"""'PZ
WA.'TI:I:t CALCULATION WORKSHEET FOR~~~.::!'t ~c..k~'I_~~~d_________---~:~~____
......,.CCWSCl' MOJI!:T ----
19:18
920589312116
ONEILL
INFO ~MA.TION REQUIRED TO CALCULATE WATER SERVice SIZE F(....,J" T<<...k
1. Demand or building in gallons pet minute. WSFU's _;~: ~_ :: (OPM) 20.. ("
2, Differertee in elevalion from main or extemal pressure tank to bUilding control valve. (feel)_L-
3, Size of the waler meter. (When applicable) 518" __' 3W L 1" __,1-1/2" __,2" __' 3" __' 4" .....:.~ 6" -
4. Developfd lenglh from main or external pressure tank 10 building control 1I..lve. (feet) _5~_
5. Low pressure at main in slreet or extemal pressure tank. (pSig)~,?__
C.Jy o.r O\h~
4/lo/0"{
12.; 02 PM
CAI~r::lJLATE WATER SERVICE PRESSURE: LOSS
6.
Low pressure at main in street or extemal pressure lank. (value of # 5 above)
Water service diameter is J~ _' Material is Ahl-~~.?'_I.:-'l!._--_. Pressure loss
per 100 n II __~:.!: lbs. X __~L(decimal equivAlent of service length, i.e.: 65ft !!: .65}
55
7.
\ .~ S""
....------
(Subtract line 7. from line 6.) subtotal _53..._$ ~
8.
Determine pressure gain or loss due to elevation.
(multiply the lIalue of # 2 above by .434)
value of "8" ~!!_~
9. Available pressure after the bldg. control valve. (Subtract or add line 8. Enter In ~B..) subtotal _52.= CzS "2..
CAII.,GULATE THE PRESSURE AVAILABLE FOR UNIFORM LOSS (VALUE OF "A")
S.
C.
Available pressure aflerthe bldg. CDntrol valve. (from "9"lIbove) Value of.SN .!?z..l.~Z
Pressure loSS of water meter (when meter is required or inslalled) Value of .C" -7_-
(Subtract line C. from line e.) subtotal _'i~ "~z..
D.
Pressure at controlling fixture. "P8v
(Col'ltrolling fixture Is __
Value of"O" 2,0
(S~btracl the value of D.) subtotal _'? s. be2
E.
Difference in elevation between the building control valve
and the controlling fixture in feet ~..L_ x .434 psi/fe.
Valueof"e" q.C\a'l
-~-
(Subtract the value of E.)'..subtotat _J~. 7_
F.
Pressure 10$s due to water treatment devices. Instantaneous
water heatEtrs and baddlow pteventers whic:;h serve the
controlling "xlure. 'nt'
(Pressure loss due to _____ P
Value of "F- _1__
----~---(~ubttaet the villue of F.) subtotal _~ 5.'1._
G.
Developed length from building control va've to contrOlling
fheMe in feet __~1._ X 1.5
Value of "G. Ct> '3
---
_~"19Z0("3
A.
. I'h. (Divide by the value of G.) subtotal
(Water distribution piping material is _.!"'_~~_____)
( Multiply by
Coppe ~
Pressure available for uniform loss
100_
25
---
"A" "l
110. ""'1 r -111\0 "'"
I