Loading...
HomeMy WebLinkAbout0107680-Building e OSHKOSH ON THE WATER Job Address 1250 JUDY LEE DR CITY OF OSHKOSH No 107680 BUILDING PERMIT - APPLICATION AND RECORD Owner RUSCH HOMES LLC Create Date 04/16/2004 Designer Contractor RUSCH HOMES LLC Category 110 - New Single Family Plan F1-037-0404R Type 18 Building 0 Sign 0 Canopy 0 Fence 0 Raze Zoning R-1 Class of Const: 8 Size Irrg Unfinished/Basement 730 Sq.Ft. ~ Sq. Ft. Rooms 6 Height 22 Ft. Bedrooms 3 Stories 2 Baths 3 U Projection 1 Finished/Living Canopies 0 Garage ~ Sq. Ft. Signs 0 Foundation 8 Poured Concrete 0 Floating Slab 0 Concrete Block 0 Post 0 Pier 0 Treated Wood 0 Other Occupancy Permit Required Flood Plain No Height Permit Not Required Park Dedication Required # Dwelling Units # Structures NSFR/ New 2 story with 2 car attached garage. NO DECK OR PATIO. Driveway shall not exceed 20' wide at the front property line. Use/Nature of Work HVAC Contractor CONDON TOTAL COMFORT Plumbing Contractor HANSON QUALITY PLUMBING Electric Contractor CUMINGS ELECTRIC INC Fees: Valuation $85,000.00 Plan Approval $75.00 Permit Fee Paid $364.00 Park Dedication $200.00 Issued By: Date 04/26/2004 Final/O.P. 00/00/0000 U Permit Voided 1 Parcelld # 1342505000 In the performance of this work I agree to perform all work pursuant to rules governing the described construction. While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement holder(s) and to secure any necessary approvals before starting such activity. Signature Date Address POBOX 423 Agent/Owner Omro WI 54963 - 0000 Telephone Number 685-0241 To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may continue if the inspection is not performed within two business days from the time the project is ready. ~ OSHKOSH ON THE WATER GRADE STAKE FORM Name RUSCH HOMES LLC Address Lot Block 64 Subdivision 1st Add't Pheasant Creek Zone 1250 JUDY LEE DR Grade Stake Number 7143 Create Date 04/16/2004 Street Number Lot Dimensions Building Grade Elevation Stakes Set At Site Set By 04/16/2004 D.W.G. BK - 596, P - 7 Ward I I Sidewalk Existing I, the undersigned, owner or agent of the above described property agree to have t has commenced. Department of Public Works Wisconsin Department of Industry, WISCONSIN UNIFORM Application No. Labor and Human Relations Safety and Buildings Division BUILDING PERMIT 0107680 P.O. Box 2509 APPLICATION Parcel No. Madison, WI 53701-2509 Wisconsin Statues 101.63, 101.73 PERMIT REQUESTED 0 Constr D HVAC D Elec D Plbg 0 Erosion D Other: Owner's Name Mailing Address Telephone No. RUSCH HOMES LLC PO BOX 423 Oshkosh WI 54963 - 0000 Contractor: ~ ConU ElecU HVAC U Plbg Lic/Cert # Mailing Address Telephone No. RUSCH HOMES LLC 000000 POBOX 423 Omro WI 54963 - 0 685-0241 Contractor: U Con ~ Elec U HVACU Plbg Lic/Cert # Mailing Address Telephone No. CUMINGS ELECTRIC INC 170792 PO BOX 749 NEENAH WI 54957 - 749 920-722-1240 Contractor: U Con U Elec ~ HVAC D Plbg Lic/Cert # Mailing Address Telephone No. CONDON TOTAL COMFORT 3202 PO BOX 184 RIPON W 54971 -184 920-748-5050 Contractor: U Con D Elec D HVAC 0 Plbg Lic/Cert # Mailing Address Telephone No. HANSON QUALITY PLUMBING 550 N BLUEMOUND RD APPLETON WI54914 -0 730-0205 PROJECT LOCATION Lot Area Sa. ft. 1/4, 1/4,Section ,T N,R E(or)W Building Address Subdivision Name Lot No. Block No. 1250 JUDY LEE DR 1 st Add't Pheasant Creek 64 Zoning District(s) I Zoning Permit No. Front I Rear Left Right ~ ft. ft. ft. ft. 1. PROJECT 3. OCCUPANCY 9. HVAC EQUIPMENT 12. ENERGY SOURCE ~ New D Repair 0 Single Family Entrance Panel ~ Forced Air Furnace Fuel Nat. L.P. Oil Elec. Solid Sola D Alteration D Two Family D Radiant Baseboard or Panel Gas * D Raze Size: 200 amp D Addition D Garage Service: D Heat Pump Space Htg 0 D D D D D D Move D Other (print): D Overhead D Boiler Water Htg 0 D D D D D D Other: 0 Underground D Central Air Conditioning * U Dwelling unit will have 3 kilowatt or 4. CONST. TYPE 7. FOUNDATION - 0 Other - more installed electric space heating equip. 2. AREA INVOLVED 0 Site Constructed U Concrete 10. PLUMBING Infiltration control option is: D Full sealing Unfinished D Manufactured D Masonry Sewer of joints. D Blower door test. D Exterior Basement 730 Sq. ft. 5. STORIES D Treated Wood 0 Municipal air infiltration barrier. Living Area 1519 Sq. ft. D 1-Story D Other D Septic 13. HEAT LOSS (Calculated) 8. USE 0 2-Story Permit No. Envelope 23807 BTU/HR Garage 467 Sq. ft. D Other D Seasonal 11. WATER Infiltration 13819 BTU/HR 0 Permanent 0 Municipal Utility 14. EST. BUILDING COST D Plus Basement D Other D Private On-Site Well $110,000.00 The applicant aç¡rees to comply with all applicable codes, statues and ordinances and with the conditions of this permit, understands that the issuance of the permit creates no legal liability, express or implied, on the Department or municipality; and certifies that all the above information is accurate. APPLICANT'S SIGNATURE DATE SIGNED APPROVAL CONDITIONS This permit is issued pursuant to the following conditions. Failure to comply may result in suspension or revocation of this permit or other penalty SEE "STANDARD CONDITIONS OF APPROVAL" SHEET ~~S~~ND~CTION D Town D Village 0 City D County U State of: Municipality Number of Dwelling Location: City Of Oshkosh 7 a - 2 6 6 FEES: PERMIT(S) WIS. UNIFORM PERMIT PERMIT ISSUED BY: ISSUED SEAL NO. Plan Review $75.00 EI Co",t,"dloc HVAC Name JOHN ZARATE Inspection Electrical Wis. Permit Seal $30.00 D Plumbing Date 4/19/04 Other 0 Erosion Total $105.00 D 306851 Cert. No. 70330 SBD-5823 (R. 07/92) e OSHKOSH ON THE WATER PARKLAND DEDICATION FEE COLLECTION RECORD Job Address 1250 JUDY LEE DR Date 04/26/2004 Name RUSCH HOMES LLC Address PO BOX 423 Oshkosh WI 54963 Subdivision 1 st Add't Pheasant Creek Lot 64 Building Permit Number 0107680 Number of Dwelling Units Number of Structures Fee Required $200.00 Fee Paid Owner's Signature Date Inspector's Signature Date CITY OF OSHKOSH STANDARD CONDITIONS OF A.PPROVA.L ----- Project Address Izso ~vd,! Le.... 1¥ Permit # Please read the following information and sign at the bottom to acknowledge that you have read and agree to comply with these coriditioriš. .. . . .. . . . . .. 1. All habitable rooms must be provided with 8% light and 3.5% ventilation. Bedrooms located on the second floor or below ground levelm\ïsfbeprciŸided"Wíilî¡;grešswrndõwš . in addition to the light and ventilation requirements. Basement windows are also required to have window well areas in accordance with ILHR2Lö3~"" .' -.... 2. Garage spaces shall be separated from the({weflingíin.iiiri accorããD.ce wIth fL1i:lf2[Ü8: The door and fi:ame assembly between the dwelling unit and an attached garage shall be labeled by an independent testing agencv as having a minimum fire-resistive rating of 20 minutes. All drywalljoirits are reCjÜired to be taped/sealed unless thejoil1tsarefitted so that the gap is no more than a dimes thickness ( 1/20-inch) and backed by solid wood or drywall with the joints staggered. . 3. All penetrations in exterior walls must be sealed prior to the insulation inspection. This includes holes in the top and bottom plates, gaps around heating ducts, and holes in the return air spaces. 4. Smoke detectors are required on every floor and within 6' of all bedrooms. Tliesmoke detectors aJ:'e required to be hardwired and interconnected. 5. Hydromassage tubs are required to have an access panel to motor. The access panel must be accessible without removing the finish of the house. 6. All overfi:aming must be designed by the trUss manufacturer, according to standards set by the truss plate institute, or structural calculations must be provided prior to the rough building inspection. 7. Truss plans must be submitted and approved prior to framing the roof. 8. Truss plans including the truss layout must be provided on site at the rough building inspection. In addition to the truss planš, microlam calculations must be provided on site at the rough building inspection for all micro lams with point loads on them. 9. Calculations must be provided for all cantilevered floors with point loads. Floor trUsses and TJI's must be designed for the cantilevered areas. 10. 11. 12. 13. 14. 15. 16. The property owner and applicant is responsible for compliance with ILHR 21.125 (Erosion Control). When installing access drives, a minimum of2"-3" diameter stone is required in addition to a minimum of 6" depth, 30'-50' length, and l4'-20'width. Erosion control measures must be maintained until the lawn is estabU§h~sL, . "-"""""~' All storm seVl.er inlets must be protected with approved erosion control devices. Tracking (i.e. sediment) must be removed from the street at the end of each workday. Repair any siltation or erosion danlage to adjoining surfaces and drainageways resulting from land dev~lopment or disturbing activities. The building placard must be posted on site at all times. QIlç~tJ¡e.r<)ugh framing is up the placard must be posted on the patio door or on a kitchen window. If the placard is not present at any inspection, stop work orders will be posted. Additional placards can be obtained through our department if the cards are misplaced. All mechanicals ll1l!stbe r<:Jughed in prior to requesting the rough building inspection. If on the inspection themechanicals are not roughed in, the inspection will fail and a $100 re-inspection fee will be charged. Attached is a copy of the final inspection checklist. At the final inspection all items on this list m¡¡st be completed to avoid the $100 re-inspection fee per inspection. When requesting final inspections please note that a minimum of 2 days notice is needed from the time the inspection is ready. Furniture is only allowed to be placed in the center of the garage floor and a minimum of a 3' pathway must be provided around the walls of the garage. At the fiIlal inspection no furniture or personal belongings are allowed in the house. Appliances such as the. stove, refrigerator, washer, and dryer are not to be set in place due to the electrical inspector needing to look at the power serving the appliances. A 6' stepladder must be on site at the final inspection to provide access to the attic. The building placard must remain on the patio door or on a kitchen window until occupancy is approved. Occupancy is not allowed prior to the placard having all of the final inspection approved stickers on the backside. If occupancy occurs prior to the inspections being approved daily citations will be issued with no further notice beillg given. 17. All site grading must be done in accordance with the approved drainage plan on file in the p"'li, ",o,k,om«, 'id ftoo,. ~ S~l- 4ArfA~l ì çÅ. - ~", b 0 0 CD ;;. ~ ";" )( ':(.0 Y.o )(CD 0 0 0 CD 0 ~ N .,.- ~ ;:;\ ~;;¡. \y~ O~ NI~ .,.- 0 CD 0 0 0 CD ~t..tr<- ..;¡ ~ õ ~ " --.::¡ ': ~ .....:::\ -<: r ¡:; '--> -<: -" ""' 120.00' 0 0 0 CD b ' 0 0 CD ----, ~ì- 0 0 0 CD I b 0 0 CD Lot 64 - 1st Add'n to Pheasant Creek Farm 1250 Judy Lee Dr. .+, s ~ OJHKOfH o~~ 10 15 20 25 - Feet 1 inch equals 20 feet DISCLAIMER This map Is nelthe, a legally recorded map nor e sulVey and lis not Intanded to be used es one. This drawing Is e compl~tion of records. date and Infonnetlon laceted In verlous city. county and slale offices and other sources e_ng the area shown and h Isto be used forreferenœ purposes only. The Chy of Oshkosh. not ,",penslble for eny lna"",rades herein contained. ~ discrepancies era f,"nd, please contad the COy of Oshkosh. Source: City of Oshkosh G.I.S. Monday, December 01, 2003