HomeMy WebLinkAboutItem VIPLAN COMMISSION STAFF REPORT APRIL 21, 2020
ITEM VI: RESIDENTIAL DESIGN STANDARDS VARIANCE TO ALLOW WINDOW
AND DOOR AREAS COMPRISING LESS THAN THE CODE MINIMUMS
FOR FRONT AND STREET SIDE FACADES ON A PROPOSED HOUSE AT
1302 EASTMAN STREET
GENERAL INFORMATION
Applicant/Owner: Habitat for Humanity of Oshkosh Inc.
Action(s) Requested:
The applicant is requesting approval of a variance from the City's Residential Design Standards
to allow window and door areas comprising less than the code minimums for front and street
side facades on a proposed house at 1302 Eastman Street.
Applicable Ordinance Provision the Variance is being requested:
Code Reference Regulation
Section 30-241(D)(6)(b) A front facade must have a minimum of 25 percent of its wall
space devoted to window or door openings.
Section 30-241(D)(6)(c) A street side facade must have a minimum of 15 percent of its wall
space devoted to window or door openings.
Property Location and Background:
The subject property is a vacant corner residential lot located at 1302 Eastman Street and is
approximately 9,504 square feet in area. The lot is at the corner of Eastman Street and E.
Tennessee Avenue. The property previously contained a 1,761 square foot 2 story single-family
residential structure which was built in 1920 according to the City of Oshkosh Assessor website.
The previous house on the site was demolished prior to Habitat for Humanity purchasing the
site. Habitat for Humanity now has plans to redevelop the site. The surrounding area consists
predominately of single and two-family uses with some multi -family and institutional uses.
The immediate properties on the east, south and north sides of the subject property are single-
family uses with varying character and scale. The property adjacent to the subject parcel on the
west is a multi -family property. The subject property and properties immediately surrounding
it on the east, south and north are zoned Two -Flat Residential-10 (TR-10). The property
immediately across the street to the west is a multi -family property with multiple buildings.
The applicant is proposing to construct a new single-family owner -occupied home on the
currently vacant parcel. The applicant has had discussions with staff and submitted plans and
elevations for the home proposed on the parcel. Staff informed the applicant that the front and
street side elevations were deficient in window and door area. The applicant revised the plans
and elevations and added window area to the front and street side facades. Staff recalculated
the window and door percentages for both facades and determined that both percentages were
much closer to the code minimums but still short of the requirements. Due to this, staff
ITEM VI-1302 Eastman Street - Design Standards Variance
Paqe 1
informed the applicant that Plan Commission review and a design standards variance were
necessary.
Subject Site
Existing Land Use Zoning
Vacant Residential TR-10
Adjacent Land Use and Zoning
Existing Uses
Zoning
North
Single Family Residential
TR-10
South
Single Family Residential
TR-10
East
Single Family Residential
TR-10
West
Multi -Family Residential
MR-12
Comprehensive Plan Land Use Recommendation
Land Use
2040 Land Use Recommendation
Light Density
Residential
VARIANCE CRITERIA
The City's Zoning Ordinance establishes design standards for single and two-family homes
with the overall purpose/intent to:
"Maintain the basic architectural quality of residences within the community, to minimize adverse
impacts on adjacent properties and neighborhoods resulting from architectural and building construction
practices that may detract from the character and appearance of the neighborhood as a whole, and to
ensure compatible design between existing and new homes."
The standards apply to all new single and two-family structures constructed within the City
and include the regulation that "A front facade must have a minimum of 25 percent of its wall space
devoted to window or door openings." The standards address corner lots and state that, "A street
side facade must have a minimum of 15 percent of its wall space devoted to window or door openings. "
These standards seek to prevent blank monotonous areas on visually prominent street -facing
facades of residences.
The Plan Commission is authorized to grant variances from the strict application of the
standards when it is determined that one or more of the following apply:
1. The variance will not be contrary to the public interest.
2. Substantial justice will be done by granting the variance.
3. The variance is needed so that the spirit of the ordinance is observed.
4. Due to special conditions, a literal enforcement of the provisions of the Zoning
Ordinance will result in unnecessary hardship.
5. The variance will not allow an alteration of a historic structure, including its
use, which would preclude its continued designation as a historic structure.
ITEM VI-1302 Eastman Street - Design Standards Variance
Paqe 2
ANALYSIS
The site plan showing the proposed placement of the new home is above. The home's proposed placement
on the parcel is in line with the setbacks of the neighboring properties.
The applicant plans to construct a new owner -occupied single-family home on the currently
vacant corner parcel. The front facade would face Eastman Street and the street side facade
would face E. Tennessee Avenue. Since the parcel is a corner lot and has two street frontages,
exterior residential design standards for front and street side facades apply. The applicant has
submitted all four elevations for the proposed house and shown applicable window and door
openings on all of them. However, Plan Commission review and design standard variance
approval are only required for the Eastman and E. Tennessee Avenue facades. No minimum
window/door area percentages exist for interior side facades or rear facades. As shown in the
tables below, the elevations as proposed fall just short of the 25% and 15% minimum
window/door area required for front and street side facades, respectively. Therefore, the
applicant seeks a design standards variance.
ITEM VI-1302 Eastman Street - Design Standards Variance
Paqe 3
1302 Eastman Window and Door Areas
Front (Eastman Street) Facade
Proposed Dimensions
(WxH)
Window 1
30" x 60"
Window 2
30" x 60"
Door
36" x 80"
Window 3
30" x 60"
Window 4
30" x 60"
Total Window/Door
Area
71.90 sq. ft.
Total Facade Area
302 sq. ft.
Estimated % of
Facade Area
(Windows and
Doors)
23.58% (25%
required by code)
Window 1
30" x 60"
Window,
30" x 60"
Door
36" x 80"
Street Side (E Tennessee Ave) Facade
Proposed Dimensions
(WxH)
Window 1
30" x 60"
Window 2
30" x 60"
Window 3
30" x 36"
Window 4
30" x 60"
Window 5
30" x 60"
Total Window/Door
Area
57.5 sq. ft.
Total Facade Area
387.53 sq. ft.
Estimated % of
Facade Area
(Windows and
Doors)
14.84% (15%
required by code)
Front (Eastman) Facade (Above)
Window 3
30" x 60"
Window 4
30" x 60"
ITEM VI-1302 Eastman Street - Design Standards Variance
Paqe 4
Street Side (E Tennessee) Facade
The above images show the proposed front and street side facades for the single-family home proposed for
1302 Eastman Street.
Staff evaluated the proposed work previously described and the design of the facades in regard
to the purpose and intent of the residential design standards. The standards relate to
preserving the home's architectural integrity and the potential impact on adjacent properties,
the neighborhood character and "curb appeal" of the block. In working with the applicant, staff
considered:
• Materials (application, plans, elevations) provided by the applicant
• Potential impact of the proposed home on neighborhood character
• Whether the proposed elevations meet the letter and intent of the Residential Design
Standards
Images - Surrounding Properties (Below)
ITEM VI-1302 Eastman Street - Design Standards Variance
Paqe 5
The images on the previous page and above show some of the surrounding properties. The top image
shows the multi family property immediately across Eastman Street from the subject parcel. The middle
image shows the property across E Tennessee Avenue from the subject parcel, and the bottom image
shows the properties on the southwest corner of the Eastman-E Tennessee intersection.
Staff has had conversations with the applicant and the applicant has revised the proposed front
and street side facades to incorporate staff input. Staff determined that the window and door
area percentages for both facades were just short of meeting the ordinance minimums for front
and street side facades. Staff is of the opinion that though the proposed elevations do not meet
the letter of the ordinance, they meet the ordinance's intent. The intent of the ordinance
sections is to prevent blank, monotonous areas on facades that face public streets. The home as
proposed includes elements such as a covered front porch and a decorative vent on the front
fagade and decorative shutters on both facades. The increase in window area on both facades
from the elevations originally submitted to staff is an improvement over the original elevations.
The added window areas on the elevations shown earlier in the staff report help in preventing
the monotonous fagade areas that the ordinances seek to avoid. The applicant worked to add
window areas while maintaining the original floor plan. Additional window and door area
could impact the floor plan layout.
ITEM VI-1302 Eastman Street - Design Standards Variance
Paqe 6
The proposed additional features on the front and street side facades should also benefit the
appearance of the home. The decorative trim, shake siding and vent on the front elevation will
help to prevent potential monotony on the gable end. Decorative shutters on both street facing
elevations will help prevent blank facade areas on both elevations. The additional architectural
elements will offset the slight deficiency in window areas on the front and street side facades.
For the reasons just mentioned, staff supports the variance request.
RECOMMENDATION
Staff recommends approval of a variance from the City's Residential Design Standards to allow
for window and door areas comprising less than the code minimums for front and street side
facades on a proposed house at 1302 Eastman Street with the following conditions and finding:
Condition:
1. Home shall be constructed according to the reviewed and approved elevations. Any
deviation from the reviewed and approved elevations for the front (Eastman St.) or
street side (E. Tennessee Ave.) facades shall require a separate design standards variance
application, Plan Commission review and Plan Commission approval.
2. Design standards variance is narrow in scope, only for the window and door
percentages proposed for the front (Eastman St.) and street side fagade (E. Tennessee
Ave.) facades and shall not be construed as setting a precedent for further projects.
3. Home as constructed shall comply with all other sections as outlined in the Residential
Design Standards in the Oshkosh Zoning Ordinance.
Finding:
The variance approval as conditioned will not be contrary to the public interest. The
facades as proposed meet the intent of the applicable sections in the Residential
Design Standards.
ITEM VI-1302 Eastman Street - Design Standards Variance
Paqe 7
Please Type or Print in BLACK INK
CITY OF OSHKOSH
APPLICATION'FOR DESIGN STANDARD VARIANCE REVIEW
APPLICANT INFORMATION
Petitioner: Habitat for Humanity of Oshkosh Inc.
Petitioner's Address:
1640 S. Koeller St.
Telephone #: ( 920 235-3535
Fax: ( )
City: Oshkosh
^A
citA:
Oshkosh
Date: 4/6/2020
State: WI zip: 54902
Other Contact # or Email:
Status of Petitioner (Please Check):Owepresentative ❑ Tenant ElProspective Buyer
Petitioner's Signature (required): Date:
PROPERTY OWNER INFORMATION
Owner(s): Habitat for Humanity of Oshkosh Inc. Date: 4/6/2020
Owner(s) Address:
1640 S. Koeller St.
Telephone #: (920) 235-3535
Fax: ( )
City: Oshkosh
State: WI zip: 54902
Other Contact # or Email:
Ownership Status (Please Check): ❑ Individual ❑ Trust ❑ Partnership Xcorporation
Property Owner Consent: (required)
By signature hereon, I/We acknowledge that City officials and/or employees may, in the performance of their
functions, enter upon the property to inspect or gather other information necessary to process this application. I also
understand that all meeting dates are tentative and may be postponed by the Planning Services Division for
incomplete submissions or other administrative reasons.
Property Owner's Signature: Date: ZD
SITE INFORMATION
Address/Location of Proposed Project:
1302 Eastman Street
Proposed Project Description: Build new single family ranch home.
Current Use of Property: Vacant
Zoning:
TR-10
In order to be granted a variance, each applicant must be able to prove, in the judgment of the Oshkosh Plan
Commission, that at least one of the following criteria applies:
1) The intent of the standards have been incorrectly interpreted
2) The standards do not apply to the project
3) The enforcement of the standards cause unnecessary hardship
�i
1. Explain in detail your proposed plans and why a variance is necessary:
We will we building a new ranch home on the corner of Eastman St. and Tennessee Ave. We will be adding Architectural elements
such as shakes and a vent on the front gable, window shutters, and a hip roof on the front proch. With our home design
the window and door area on the front elevation is 1.42% under the current design standard. The right side elevation
is .16% under the current design standard.
2. Describe how the variance would not have an adverse effect on surrounding properties or
curb appeal of the neighborhood:
Many of the homes in the neighborhood do not meet the current design standard for window and
door area but do have some of the architectrual elements we will adding to our home.
3. Describe in detail the materials and construction methods that the proposed project would
use. Attach any supplementary information including, but not limited to, material data sheets,
product information, supplemental photographs, elevation plan(s) and site plan(s):
All windows, siding, and siding elements will be vinyl. Exterior doors will be fiberglass.
Paqe 9
4. Describe why the intern of the design standards have been incorrectly interpreted (if
applicable):
The intent of the design standard is to maintain and enhance the attractiveness and values of
property in the community. I believe the trade off of the architectual elements we are adding to
our home along with the slightly reduced required window and door sizes will meet this standard.
S. Describe why the design standards do not apply to this particular project (if applicable):
6. Describe the unnecessary hardship that would result if your variance were not granted (if
applicable):
Paqe 10
DSV
1302 EASTMAN ST
PC: 04-21-20
CAROL A SITZBERGER
1303 GRAND ST
OSHKOSH WI 54901
MATTHEW J/DANIELLE J HELTZ JR
1312 EASTMAN ST
OSHKOSH WI 54901
TITAN 2019 LLC
923 S MAIN ST STE E
OSHKOSH WI 54902
ALLAN L/CARLA R CHIZEK
W5661 COUNTY ROAD A
BLACK CREEK WI 54106
CEREBRAL PALSY OF MIDEAST WISCONSIN INC
1930 ALGOMA BLVD
OSHKOSH WI 54901
MICHAEL L WAGNER
1235 GRAND ST
OSHKOSH WI 54901
WILLO HOUSING CORP
PO BOX 397
OSHKOSH WI 54903
BRIAN HOLTZJMELISSA LAUGHLIN HOLTZ
1235 EASTMAN ST
OSHKOSH WI 54901
MATHEW/KAREN TONEY
1315 GRAND ST
OSHKOSH WI 54901
SHERREE J VANDENBOOGAARD
1234 EASTMAN ST
OSHKOSH WI 54901
HABITAT FOR HUMANITY OF OSHKOSH INC
PO BOX 2692
OSHKOSH WI 54903
Paqe 11
130.58'
201 205
203 207
�o
132.00' Lr)
M N
011
N
V
266.31'
256,65'
208 210 220 222
206 212 224
204 21 SUBJECT6
202 SITE
266.06'
❑
132,0'
133.68'
❑
132, 0'
❑33.44
❑
13327
V
32.0'
EJ
132.0'
132.74
a N
❑32.5'
rF-152�9
❑
Q
52.9'
��
C14 N
202
2
52.76'
0 ''
S2.76'
214A
2
S2.76'
S2.78'
S2.76'
-YJO
Ca
300
MLK
_ 132,31 1 142.35'
E CUSTER AV
132,0142.53'E�
132.0'
❑
142.6�
r
1320'
N a
❑ 1429�
a ���CiiY1
132D'
❑ a
a
Q 132.0'
O a
=,13'
r
132.0'
tr
143.28'
a ❑ M
14343'
Cl)
O
143,68'
N 13.
TENNESSEE AV
f7
N 1az.o'
143.86'
LO
❑ M
N
taz.o'
a EJ
� ❑
❑
132.0'
❑
❑a
o
T2�;
55.41'
306
S5.41'
S5.41'
S5.41' S5.41'
120.0'
'aD
o ❑
143.18'
Tin
120H 141.03'
❑41
❑6 06'
12
N
t6s
120.00' 114M'
120.00' it 2.74'
60,66I 53.00' 61,92'
17
k
402 408 414
3 56.96'
/ f J1) N 1 in = 0.02 mi
tin=120ft
City of Oshkosh maps and data are intended to be used for general identification purposes only, and C i i Y
the City of Oshkosh assumes no liability for the accuracy of the information. Those using the of
information are responsible for verifying accuracy. For full disclaimer please go to Printing Date: 31212020 Oshkosh
www.ci.oshkosh.wi.us/GlSdisclaimer Prepared by: City of Oshkosh, WI
CAUsers\minak\Desktop\2020 Plan Commission Site Plan Map Template.mxd P agEIserjrn2ak
SMU-PDJ
.aAa"-v"=
SUBJECT
SITE
!Ira
1302 EASTMAN ST
TR-10
i;:wsers\minaKwesKtop\zuzu Tian commission site Tian wrap iempiate.mxo r agoser:1mjqaK