HomeMy WebLinkAbout0107577-Building ® CITY OF OSHKOSH No 107577
OSHKOSH BUILDING PERMIT - APPLICATION AND RECO - (t4'+
ON THE WATER
Job Address 14U6_MONROE ST Owner GEURTS CUSTOM HOMES INC itr,r, ate 04/19/2004 _
Designer ' Contractor SUPERIOR BUILDERS
Category 110 - New Single Family Plan F1- 035 -0404R
Type 0 Building 0 Sign 0 Canopy 0 Fence 0 Raze
Zoning R -1 Class of Const: 8
- - -- Size irrg
Unfinished /Basement 96 Sq. Ft. Rooms 8 Height 22 Ft. 0 Projection
Finished /Living 1614 Sq. Ft. Bedrooms 3 Stories Bi -level Canopies 0
Garage 484 Sq. Ft. Baths 2 Signs 0
Foundation 0 Poured Concrete 0 Floating Slab 0 Pier 0 Other
0 Concrete Block 0 Post 0 Treated Wood
Occupancy Permit Required Flood Plain No Height Permit Not Required
Park Dedication Not Required # Dwelling Units 1 # Structures 1
Use/Nature
NSFR/ New Bi -level with 2 car attached garage and 12' x 12' deck. The driveway shall not exceed 22' wide at the front property line.
of Work
HVAC Contractor MCM AIR INC Plumbing Contractor HANSON QUALITY PLUMBING
Electric Contractor UNKNOWN ? ? ??
Fees: Valuation $105,000.00 Plan Approval $75.00 Permit Fee Paid $409.00 Park Dedication $0.00
Issued By: Date 04/20/2004 Final /O.P. 00 /00 /0000
0 Permit Voided I Parcel Id # 1507370000
In the performance of this work I agree to perform all work pursuant to rules governing the described construction.
While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work
described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement
holder(s) and to sect! - any neces ary a rovals before -sting such activity.
Signatur ° /' 4 6 0 .. 7.47_, Date�C-6f-
Agent/Owner
Address 735 FOX FIRE DR OSHKOSH WI 54904 - 0000 Telephone Number 920 - 232 -6777
To schedule inspections please call the Inspection Request line at 236 -5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
' Wiscor,sin Department of Industry, WISCONSIN UNIFORM Application No.
Labor and Human Relations
Y Buildings BUILDING P ERMIT 0107577 `'
Safety and Buildin s Division �� l ��� '
P.O. Box 2509 APPLICATION Parcel No.
Madison, WI 53701 -2509 OAS�r
Wisconsin Statues 101.63, 101.73 �. - -r
P {!ff , A ai,....,,i,. Q Constr ❑ HVAC fI Elec ❑ Plbg Q Erosion ❑ Other:
Owner's Name Mailing Address Telephone No.
GEURTS CUSTOM HOMES INC 735 FOX FIRE DR OSHKOSH WI 54904 - 0000
Contractor: ✓ Con❑ EIecH HVAC ❑ Plbg Lic/Cert # Mailing Address Telephone No
SUPERIOR BUILDERS 831271 735 FOX FIRE DR OSHKOSH WI 54904 - 0 920- 232 -6777
Contractor: H Con U Elecu HVAC]J Plbg Lic/Cert # Mailing Address Telephone No.
UNKNOWN ? ? ?? Oshkosh WI 54901 - 0
Contractor: U Con 1J Elecu HVAC ❑ Plbg Lic/Cert # Mailing Address Telephone No.
MCM AIR INC 4264 6122 COUNTY ROAD M WINNECONNI WI 54986 -9780 920 - 582 -4402
Contractor: U Con J Elec J HVAC U Plbg Lic/Cert # Mailing Address Telephone No
HANSON QUALITY PLUMBING 550 N BLUEMOUND RD APPLETON WI 54914 -0 730 -0205
19 ; r ,. i Lot Area
4 sq. ft. 1/4, 1 /4,Section ,T N,R E(or)W
Building Address Subdivision Name Lot No. Block No.
1406 MONROE ST
Zoning District(s) Zoning Permit No. Front Rear Left Right
�aw., .k�,,. % as A m z' i - 9.4 . b 1 3 w wei" 1 ,, 'i t � "' a� s:s
Q New E �, S �,,
❑ Repair 0 Si ng l e F am il y Entrance Panel Q Force Air Furnace Nat. Oil Elec. Solid Sola
❑ Alteration ❑ Two Family Size: 2 am. ❑ Radiant Baseboard or Panel Fuel Ga
E] Raze
❑ Addition _ Garage Service: ❑ Heat Pump Space Ht 0 ❑ El ❑ ❑
❑ Move ❑ Other (print): ❑ Overhead
Q Underground ❑ Boiler Water Htg 0 ❑ ❑ ❑ ❑ ❑
r � ° , _ � ] r. ❑
❑ Other: Central Air Conditioning * U Dwelling unit will have 3 kilowatt or
��� � . Other more installed electric space heating equip.
,1 . < Q Site Constructed M Concrete
Mason td .4- om " ° infiltration control option is: ❑ Full sealing
Unfinished El Manufactured El ry W o o d
Sewer
of joints. El Blower door test. ❑ Exterior
Basement 96 Sq ft. w';" _ ❑ Trea e 0 Municipal air infiltration bamer.
❑ Other
Living Area 1614 Sq. ft. II 1- Story ° rt e , . . « , ❑ Septic *°::
Garage 484 Sq ft ❑ 2 -Story Seasonal Permit No. Envelope 17814 BTU /HR
❑ Other [1] Seasonal 9878 BTU /HR
, . .
Bi -level 0 Permanent Q Municipal Utility a R ....:.,
P lus Basement ❑ Other
❑ ❑ Private On -Site Well $118,000.00
The applicant agrees to comply with all applicable codes, statues and ordinances and with the conditions of this permit, understands that the issuance of
the permit creates no legal liability, expres •r i y.lied, on th- 'epartment or municipality; and certifies that all the above information is accurate.
APPLICANT'S SIGNATURE _ ,� / /11 i DATE SIGNED O ? Q -
APPROVAL CONDITIONS This permit is issued pursuant to the following conditions. Failure to comply may result in suspension or
revocation of this permit or other penalty
SEE "STANDARD CONDITIONS OF APPROVAL" SHEET
- � �` ❑ T own ❑ Village Q City ❑ County U State of:
i w , Y
� Municipality Number of Dwelling Location:
City Of Oshkosh 7 0
2 6 6
s�w� s t o :m " m . aw^��, ,� ° � ," � x*'rw� V kw r
w ` d' `` ` ' -` r8. m ' - - " � ^ : ;� i1 ,..,....t.?,:-:,' 1 t • - tlNIFO �•,�wi •
' i�iL �t * `i ara fi '�` ° a e�'r" �Rj r s''m a �" � ' e ° ��at
$75.00 Q ��
Plan Review Construction
Inspection HVAC Name JOHN ZARATE
Electrical
Wis. Permit Seal $30.00 I I Plumbing Date 4/19/04
Other I ✓I Erosion
Total $105.00 ` 306850 Cert. No. 70330
SBD -5823 (R. 07/92)
CITY OF OSHKOSH
STANDARD CONDITIONS OF APPROVAL
Project Address 14)(o MonF Permit # I 0 / 5 7 7
Please read the following information and sign at the bottom to acknowledge that you have read
and agree to comply with these conditions.
1. All habitable rooms must be provided with 8% light and 3.5% ventilation. Bedrooms
located on the second floor or below ground level must be provided with egress windows
in addition to the light and ventilation requirements. Basement windows are also
required to have window well areas in accordance with ILHR 21.03.
2. Garage spaces shall be separated from the dwelling unit in accordance with ILHR 21.08.
The door and frame assembly between the dwelling unit and an attached garage shall be
labeled by an independent testing agency as having a minimum fire - resistive rating of 20
minutes. All drywall joints are required to be taped /sealed unless the joints are fitted so
that the gap is no more than a dimes thickness ( 1/20 -inch) and backed by solid wood or
drywall with the joints staggered.
3. All penetrations in exterior walls must be sealed prior to the insulation inspection. This
includes holes in the top and bottom plates, gaps around heating ducts, and holes in the
return air spaces.
4. Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke
detectors are required to be hardwired and interconnected.
5. Hydromassage tubs are required to have an access panel to motor. The access panel must
be accessible without removing the finish of the house.
6. All overframing must be designed by the truss manufacturer, according to standards set
by the truss plate institute, or structural calculations must be provided prior to the rough
building inspection.
7. Truss plans must be submitted and approved prior to framing the roof.
8. Truss plans including the truss layout must be provided on site at the rough building
inspection. In addition to the truss plans, microlam calculations must be provided on site
at the rough building inspection for all microlams with point loads on them.
9. Calculations must be provided for all cantilevered floors with point loads. Floor trusses
and TJI's must be designed for the cantilevered areas.
10. The property owner and applicant is responsible for compliance with ILHR 21.125
(Erosion Control). When installing access drives, a minimum of 2 " -3" diameter stone is
required in addition to a minimum of 6" depth, 30' -50' length, and 14' -20' width. Erosion
control measures must be maintained until the lawn is established.
11. All storm sewer inlets must be protected with approved erosion control devices. Tracking
(i.e. sediment) must be removed from the street at the end of each workday. Repair any
siltation or erosion damage to adjoining surfaces and drainageways resulting from land
development or disturbing activities.
12. The building placard must be posted on site at all times. Once the rough framing is up
the placard must be posted on the patio door or on a kitchen window. If the placard is not
present at any inspection, stop work orders will be posted. Additional placards can be
obtained through our department if the cards are misplaced.
13. All mechanicals must be roughed in prior to requesting the rough building inspection. If
on the inspection the mechanicals are not roughed in, the inspection will fail and a $100
re- inspection fee will be charged.
14. Attached is a copy of the final inspection checklist. At the final inspection all items on
this list must be completed to avoid the $100 re- inspection fee per inspection.
15. When requesting final inspections please note that a minimum of 2 days notice is needed
from the time the inspection is ready. Furniture is only allowed to be placed in the center
of the garage floor and a minimum of a 3' pathway must be provided around the walls of
the garage. At the final inspection no furniture or personal belongings are allowed in the
house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in
place due to the electrical inspector needing to look at the power serving the appliances.
A 6' stepladder must be on site at the final inspection to provide access to the attic.
16. The building placard must remain on the patio door or on a kitchen window until
occupancy is approved. Occupancy is not allowed prior to the placard having all of the
final inspection approved stickers on the backside. If occupancy occurs prior to the
inspections being approved daily citations will be issued with no further notice being
given.
17. All site grading must be done in accordance with the approved drainage plan on file in the
public works office, 3rd floor.
Synalure o/ArpCicanf: 2)ate: 2C 3