Loading...
HomeMy WebLinkAbout17. 19-629 DECEMBER 10, 2019 19-629 RESOLUTION (CARRIED___7-0____LOST_______LAID OVER_______WITHDRAWN_______) PURPOSE: APPROVE SPECIFIC IMPLEMENTATION PLAN FOR AUTOMOTIVE SALES/ DISPLAY AND AN AUTOMOTIVE SERVICE FACILITY; 3365 SOUTH WASHBURN STREET INITIATED BY: BERGSTROM AUTOMOTIVE PLAN COMMISSION RECOMMENDATION: Approved w/conditions WHEREAS, the Plan Commission finds that the General Development Plan and Specific Implementation Plan for the proposed planned development for automotive sales/ display and an automotive service facility at 3365 South Washburn Street, is consistent with the criteria established in Section 30-387(6) of the Oshkosh Zoning Ordinance. NOW, THEREFORE, BE IT RESOLVED by the Common Council of the City of Oshkosh that a General Development Plan and Specific Implementation Plan for the planned development for automotive sales/ display and an automotive service facility at 3365 South Washburn Street, per the attached, is hereby approved with the following conditions: 1) All vehicles parked outdoors shall be in operable condition for safe and legal performance on public right-of-way. 2) No electronic message center signs may be installed on the site. 3) Final signage plans shall meet signage standards for the Suburban Mixed Use (SMU) district and be reviewed by the Department of Community Development. 4) Base Standard Modification to allow lighting levels to exceed 0.5 foot-candles along the north property line. 5) Base Standard Modification to allow front and side building facades to be clad in less than 50% Class I materials. 6) Metal panels on east, north and south elevations shall be consistent in material and appearance with the neighboring Bergstrom buildings. 7) Final landscaping plan shall be revised to meet all code requirements. 8) Final landscaping plan shall be approved by the Department of Community Development. .... City Oshkosh TO: Honorable Mayor and Members of the Common Council FROM: Mark Lyons Planning Services Manager DATE: December 5, 2019 RE: Approve Specific Implementation Plan for Automotive Sales/ Display and an Automotive Service Facility; 3365 South Washburn Street (Plan Commission Recommends Approval) BACKGROUND The subject property is a vacant parcel located at 3000 block of S. Washburn Street and is approximately 25.73 acres in area. The surrounding area consists predominately of commercial uses and vacant/open space uses. The subject property is zoned Suburban Mixed Use with a Planned Development Overlay (SMU-PD). The surrounding area is zoned SMU- PD along with MR-12 to the west. ANALYSIS The applicant is requesting General Development Plan (GDP) and Specific Implementation Plan (SIP) approval for auto sales / display and an auto body shop at the subject site. The proposed plans include a 36,750 sq. ft. building with vehicle service bays in the south and west portions of the building and associated parking lot surrounding the building. The site plan indicates a dumpster enclosure at the southwest corner of the building. The material is shown as precast concrete which matches the proposed building materials. The applicant is proposing a single access to the site from S. Washburn Street. The site plan shows a total of 602 parking spaces. The spaces are split between customer parking, employee parking and spaces for vehicle inventory. The applicant has allocated approximately 158 spaces for customer parking, employee parking and vehicles waiting for service, with the remaining 444 spaces being devoted to sales and display. The plan also shows two drive aisles connecting to the Bergstrom site to the north. A cross -access agreement will need to be filed for these drive aisles. The submitted plan included part of the finalized sign plans. The east elevation rendering includes wall signage and a proposed pylon sign. The sign plan shows a 35' tall pylon, approximately 475 sq. ft. sign area, including a 124 sq. ft. Electronic Message Center (EMC). In May of 2012, a Planned Development amendment was approved for the Bergstrom site City Hall, 215 Church Avenue P.O. Box 1130 Oshkosh, WI 54903-1 130 920.236.5000 http://www.ci.oshkosh.wi.us immediately to the north (3365 S. Washburn St.) which included a 1,165 sq. ft. EMC with a condition of a deed restriction not permitting any additional electronic message centers on the properties comprising the Bergstrom Import Super Center. Upon staff review, it appears that deed restriction may never have been recorded. Code allows a maximum of 100 sq. ft. of EMC per property, therefore the 1,165 sq. ft. of EMC previously approved is the equivalent of 11.65 properties worth of EMC. Staff is recommending a condition that no electronic message centers may be installed on the site and finalized sign plans must meet signage requirements for the Suburban Mixed Use (SMU) district and be submitted for review by the Department of Community Development. A landscaping plan has been submitted with the application and includes a variety of proposed shrubs and trees for building foundation, paved area, street frontage and yard landscaping. The landscaping plan shows a total of 300 building foundation landscaping points where 392 points are required. The plan exceeds point requirements for paved areas with 3,524 points where 2,985 points are required, while also exceeding the minimum percentages for tall trees and shrubs. However, four of the proposed parking rows are missing intermediate landscape islands. The landscape plan shows a total of 676 street frontage landscaping points, where code requires 370 points. The applicant will need to revise the landscaping plan to comply with the landscaping requirements. The applicant submitted a lighting plan that appears to meet lighting standards with the exception of the lighting levels along the north property line and the proposed fixture mounting height. This can be addressed during the Site Plan Review process. Drainage plans have been submitted and are being reviewed by the Department of Public Works. Finalized storm water management plans will need to be submitted and approved as part of the Site Plan Review process. The proposed building will be constructed of a combination of metal panels, precast concrete, split -face CMU and storefront glass. The applicant is requesting a BSM as the east, north and south facades will not meet the requirement of 50% Class I materials. The applicant is proposing to use aluminum composite metal panels as an alternate Class I material on the east elevation and front portions of the north and south elevations. Precast concrete wall panels, which is a Class IV material, are proposed on the rear (west) fagade and back portions of the north and south facades. According to the applicant, the metal panels shown on the east, north and south facades will be visually compatible with the neighboring buildings in the area. The applicant is proposing the precast concrete in lieu of split -faced CMU in order to meet requirements of the State Energy Code, which was revised to include continuous insulation at exterior walls. The applicant also notes that the wall panel finish will have a similar appearance to split -face CMU, which is a Class II material. FISCAL IMPACT Approval of this project should result in an increase in assessed property value for the site and should require no additional city service provision. The owner is anticipating spending approximately $6,000,000 on the development. City Hall, 215 Church Avenue P.O. Box 1 130 Oshkosh, WI 54903-1130 920.236.5000 http://www.ci.oshkosh.wi.us RECOMMENDATION The Plan Commission recommended approval of the General Development Plan and Specific Implementation Plan with findings conditions at its December 3, 2019 meeting. Respectfully Submitted, Mark Lyons Planning Services Manager Approved: Mark A. Rohloff City Manager City Hall, 215 Church Avenue P.O. Box 1130 Oshkosh, WI 54903-1 130 920.236.5000 http://www.ci.oshkosh.wi.us j__� a ....... _............ LL................................. ......... _._..._.._.. ............................... co Fr F� I co W � 7"t" Ulu 1 e r�a` 3 3r I f :. S rtarc F+ � o U - z a N w m; ......................... . ......................... SITE Q w J s y O t o N 1 in=0.06mAGENORN i 1 in=300ft City of Oshkosh maps and data are Intended to be used for general identification purposes only.. and . ! the City of Oshkosh assumes no liability for the accuracy of the information. Those using the Printing Date: 1118I2019 information are responsible for verifying accuracy. For full disclaimer please go to Oshkosh m-.w.ci.oshkosh.wi.us-GlSd sclaimer Prepared by: City of Oshkosh, WI G!S',P!enninMP!an C mmissirn Site Plan flap Tem ate?lan Cainmiss.ai Site. Plan Atari Templatanxti ITEM: GENERAL DEVELOPMENT PLAN AND SPECIFIC IMPLEMENTATION PLAN APPROVAL FOR AUTOMOTIVE SALES / DISPLAY AND AN AUTOMOTIVE SERVICE FACILITY LOCATED SOUTH OF 3365 S. WASHBURN STREET Plan Commission meeting of December 3, 2019 GENERAL INFORMATION Applicant: Gries Architectural Group, Inc. Owner: Bergstrom Automotive Actions Requested: The applicant requests approval of a General Development Plan and Specific Implementation Plan for automotive sales / display and an automotive service facility at the property located south of 3365 S. Washburn Street. Applicable Ordinance Provisions: Planned Development standards are found in Section 30-387 of the Zoning Ordinance. Property Location and Background Information: The subject property is a vacant parcel located at 3000 block of S. Washburn Street and is approximately 25.73 acres in area. The surrounding area consists predominately of commercial uses and vacant/open space uses. The subject property is zoned Suburban Mixed Use with a Planned Development Overlay (SMU-PD). The surrounding area is zoned SMU-PD along with MR-12 to the west. Subject Site Existing Land Use Zoning Vacant SMU-PD Adjacent Land Use and Zoning Existing Uses Zoning North Auto Sales (Bergstrom) SMU-PD West Vacant MR-12 South Open Space/Recreational SMU-PD East Public Right -of -Way (S. Washburn St.) A-2 (County) Comprehensive Plan Comprehensive Plan Land Use Recommendation Land Use 2040 Comprehensive Land Use Recommendation Interstate Commercial ANALYSIS Use/Site Design The applicant is requesting General Development Plan (GDP) and Specific Implementation Plan (SIP) approval for auto sales / display and an auto body shop at the subject site. The proposed plans include a 36,750 sq. ft. building with vehicle service bays in the south and west portions of the building and associated parking lot surrounding the building. The total impervious surface area proposed for the site is 6 acres, which is 23.32% of the site, well under the 70% maximum for the Suburban Mixed Use (SMU) district. The site plan indicates a dumpster enclosure at the southwest corner of the building. The material is shown as precast concrete which matches the proposed building materials. The enclosure must be 6' tall and constructed of wood or one or more materials used on the exterior of the main building. This can be addressed during the Site Plan Review process. Access/Parking The applicant is proposing a single access to the site from S. Washburn Street. The site plan shows a total of 602 parking spaces. The spaces are split between customer parking, employee parking and spaces for vehicle inventory. The applicant has allocated approximately 158 spaces for customer parking, employee parking and vehicles waiting for service, with the remaining 444 spaces being devoted to sales and display. The plan also shows two drive aisles connecting to the Bergstrom site to the north. A cross -access agreement will need to be filed for these drive aisles. Staff is recommending a condition that all vehicles parked outdoors shall be in operable condition for safe and legal performance on public right-of-way. Signage submitted plan included part of the finalized sign plans. The east elevation rendering includes wall signage that appears to be in compliance with signage standards for the SMU district. The site plan shows a proposed pylon sign within the 25' front setback. The pylon sign will need to be relocated out of the front yard setback. The sign plan shows a 35' tall pylon, approximately 475 sq. ft. sign area, including a 124 sq. ft. Electronic Message Center (EMC). In May of 2012, a Planned Development amendment was approved for the Bergstrom site immediately to the north (3365 S. Washburn St.) which included a 1,165 sq. ft. EMC with a condition of a deed restriction not permitting any additional electronic message centers on the properties comprising the Bergstrom Import Super Center. Upon staff review, it appears that deed restriction may never have been recorded. Code allows a maximum of 100 sq. ft. of EMC per property, therefore the 1,165 sq. ft. of EMC previously approved is the equivalent of 11.65 properties worth of EMC. Staff is recommending a condition that no electronic message centers may be installed on the site and finalized sign plans must meet signage requirements for the SMU district and be submitted for review by the Department of Community Development. Landscaping A landscaping plan has been submitted with the application and includes a variety of proposed shrubs and trees for building foundation, paved area, street frontage and yard landscaping. The landscaping plan shows a total of 300 building foundation landscaping points where 392 points Item — GDP/SIP South of 3365 S. Washburn St. are required, with none located on the street/main entrance side where code requires a minimum of 50% of the building foundation landscaping points. As the proposed shrubs for the paved areas exceeds the minimum requirement, some of these shrubs can be relocated to the building foundation to meet the 392 point requirement with a minimum of 196 located on the front (east) side of the building. The applicant will need to revise the landscaping plan to comply with the building foundation landscaping requirements. The plan exceeds point requirements for paved areas with 3,524 points where 2,985 points are required, while also exceeding the minimum percentages for tall trees and shrubs. However, four of the proposed parking rows are missing intermediate landscape islands, as code allows a maximum of 180 feet between islands. A tall deciduous/overstory tree will also need be added to both of the eastern -most parking row ends. These landscape islands can be addresses as part of the Site Plan Review process. The landscape plan shows a total of 676 street frontage landscaping points, where code requires 370 points. Code requires that a minimum 50% of required street frontage landscaping be devoted to medium trees. Of the street frontage trees shown on the plan, only the (6) "Red Barron Crabapple" trees are considered medium trees for a total of 60 points, where 185 points medium tree points are required. The applicant also indicates 20 Autu_mn Blaze Maples will be used on the site. Autumn Blaze Maples are identified as a species to use sparingly within the landscaping ordinance due to over -planting. Staff encourages the applicant to consider an alternative to the Autumn Blaze Maples. The applicant will need to revise the landscaping plan to comply with the street frontage landscaping requirements. Site Lighting The applicant submitted a lighting plan that appears to meet lighting standards with the exception of the lighting levels along the north property line and the proposed fixture mounting height. The proposed lighting meets the .4 foot-candle minimum requirement for parking areas except for three stalls on the northern end of the parking lot as well as at the entrance to the site. This can be addressed during the Site Plan Review process. The photometric plan shows portions of the lot along the north property line exceed the maximum of .5 foot-candles of light trespass at the property line. Staff is supportive of a Base Standard Modification (BSM) to allow the additional light trespass as it is extending to the area along the neighboring parking lot (also owned by Bergstrom) and should not cause any concerns. The proposed 24 ft. height of the light poles/fixtures exceeds the 20 foot maximum height for the SMU zoning district. The lighting fixture heights will need to be reduced to 20 feet. This can be addressed during the Site Plan Review process. Storm Water Management Drainage plans have been submitted and are being reviewed by the Department of Public Works. Finalized storm water management plans will need to be submitted and approved as part of the Site Plan Review process. Item — GDP/SIP South of 3365 S. Washburn St. 3 Building Elevations The proposed building will be constructed of a combination of metal panels, precast concrete, split -face CMU and storefront glass. The applicant is requesting a BSM as the east, north and south facades will not meet the requirement of 50% Class I materials. The applicant is proposing to use aluminum composite metal panels as an alternate Class I material on the east elevation and front portions of the north and south elevations. Precast concrete wall panels, which is a Class IV material, are proposed on the rear (west) fagade and back portions of the north and south facades. According to the applicant, the metal panels shown on the east, north and south facades will be visually compatible with the neighboring buildings in the area. The applicant is proposing the precast concrete in lieu of split -faced CMU in order to meet requirements of the State Energy Code, which was revised to include continuous insulation at exterior walls. The applicant also notes that the wall panel finish will have a similar appearance to split -face CMU, which is a Class II material. Staff is supportive of the BSM to allow front and side facades not predominantly clad in Class I materials with a condition that the metal panels be consistent in material and appearance to the neighboring "Bergstrom" buildings. Overall Site The applicant is requesting BSM's related to building materials and site lighting. To offset the requested BSM's, the applicant is proposing approximately 25% additional landscaping over the minimum code requirements. Staff is comfortable that the applicant has adequately offset the requested BSM's and the overall site is complimentary to the surrounding area. FINDINGS/RECOMMENDATION/CONDITIONS In its review and recommendation to the Common Council on an application for a Planned Development district, staff recommends that Plan Commission make the following findings based on the criteria established by Chapter 30-387 (C)(6): (a) The proposed Planned Development project is consistent with the overall purpose and intent of this Chapter. (b) The proposed Planned Development project is consistent with the City's Comprehensive Plan and other area plans. (It is the responsibility of the City to determine such consistency.) (c) The proposed Planned Development project would maintain the desired relationships between land uses, land use densities and intensities, and land use impacts in the environs of the subject site. (d) Adequate public infrastructure is or will be available to accommodate the range of uses being proposed for the Planned Development project, including but not limited to public sewer and water and public roads. (e) The proposed Planned Development project will incorporate appropriate and adequate buffers and transitions between areas of different land uses and development densities/intensities. Item — GDP/SIP South of 3365 S. Washburn St. 4 (f) The proposed Planned Development project design does not detract from areas of natural beauty surrounding the site. (g) The proposed architecture and character of the proposed Planned Development project is compatible with adjacent/nearby development. (h) The proposed Planned Development project will positively contribute to and not detract from the physical appearance and functional arrangement of development in the area. (i) The proposed Planned Development project will produce significant benefits in terms of environmental design and significant alternative approaches to addressing development performance that relate to and more than compensate for any requested exceptions/base standard modifications variation of any standard or regulation of this Chapter. (j) For Planned Development projects that are proposed to be developed in phases, the applicant can provide a timeline for development and can demonstrate that the project would be successful even if all phases were not or could not be completed. Staff recommends approval of the General Development Plan and Specific Implementation Plan with the findings listed above and the proposed following conditions: 1) All vehicles parked outdoors shall be in operable condition for safe and legal performance on public right-of-way. 2) No electronic message center signs may be installed on the site. 3) Final signage plans shall meet signage standards for the Suburban Mixed Use (SMU) district and be reviewed by the Department of Community Development. 4) Base Standard Modification to allow lighting levels to exceed 0.5 foot-candles along the north property line. 5) Base Standard Modification to allow front and side building facades to be clad in less than 50% Class I materials. 6) Metal panels on east, north and south elevations shall be consistent in material and appearance with the neighboring Bergstrom buildings. 7) Final landscaping plan shall be revised to meet all code requirements. 8) Final landscaping plan shall be approved by the Department of Community Development. The Plan Commission approved of the General Development Plan and Specific Implementation Plan as requested with findings and conditions noted. The following is the Plan Commission's discussion on this item. Site Inspections: Report: Mr. Fojtik and Mr. Hinz reported visiting the site. Staff report accepted as part of the record. The applicant requests approval of a General Development Plan and Specific Implementation Plan for automotive sales / display and an automotive service facility at the property located south of 3365 S. Washburn Street. Item — GDP/SIP South of 3365 S. Washhurn St. Mr. Slusarek presented the item and reviewed the site and surrounding area as well as the land use and zoning classifications in this area. The proposed plans include a 36,750 sq. ft. building with vehicle service bays in the south and west portions of the building and associated parking lot surrounding the building. The site plan indicates a dumpster enclosure at the southwest corner of the building. The applicant is proposing a single access to the site from S. Washburn Street. The site plan shows a total of 602 parking spaces which are split between customer parking, employee parking and spaces for vehicle inventory. Finalized code -compliant sign plans, landscaping plan, lighting plan and storm water management plans will need to be submitted and approved. The proposed building will be constructed of a combination of metal panels, precast concrete, split -face CMU and storefront glass. The applicant is requesting a BSM as the east, north and south facades will not meet the requirement of 50% Class I materials. The applicant is proposing to use aluminum composite metal panels as an alternate Class I material on the east elevation and front portions of the north and south elevations. Precast concrete wall panels, which is a Class IV material, are proposed on the rear fagade and back portions of the north and south facades. He said staff recommends approval of the General Development Plan and Specific Implementation Plan with the findings and conditions as listed in the staff report. Mr. Fojtik opened technical questions to staff. Mr. Ford asked if EMCs were allowed under code. Mr. Lyons explained the code allows one EMC per property at a maximum of 100 square feet. Mr. Ford inquired about the history of the EMC for the Bergstrom site. Mr. Lyons explained the history of the EMC. He said instead of having one EMC for each site, Bergstrom would aggregate all of them into one central location. He said staff feels with the additional site, the original EMC should suffice as it is equivalent to 11 developments worth of EMCs. Mr. Ford asked for confirmation that the decision for the EMC was based off of a pervious recommendation. Mr. Lyons confirmed it was. Ms. Propp asked what materials the other Bergstrom buildings were made of and if there were any Class I materials. Mr. Lyons said he did not know the percentage but knows the metal cladding on the front is consistent with the other Bergstrom buildings. He explained staff is in support because it is consistent with the existing development pattern. He said some of the buildings were approved prior to the current code requirements. He commented the metal paneling the applicant is requesting is a high quality material. He said the glass on the building is a Class I material. Item — GDP/SIP South of 3365 S. Washburn St. Mr. Perry asked what the current percentage is of the Class I materials. Mr. Lyons and Mr. Slusarek replied it is 16% short on Class I materials for the east fagade. Mr. Fojtik asked if there were any public comments and asked if the applicant wanted to make any statements. There were no statements from the applicant. There were no public comments on this item. Mr. Fojtik closed public comments and asked if the applicant wanted to make any closing statements. There were no closing statements from the applicant. Motion by Hinz to adopt the findings and recommendation as stated in the staff report. Conditions: 1. All vehicles parked outdoors shall be in operable condition for safe and legal performance on public right-of-way. 2. No electronic message center signs may be installed on the site. 3. Final signage plans shall meet signage standards for the Suburban Mixed Use (SMU) district and be reviewed by the Department of Community Development. 4. Base Standard Modification to allow lighting levels to exceed 0.5 foot-candles along the north property line. 5. Base Standard Modification to allow front and side building facades to be clad in less than 50% Class I materials. 6. Metal panels on east, north and south elevations shall be consistent in material and appearance with the neighboring Bergstrom buildings. 7. Final landscaping plan shall be revised to meet all code requirements. 8. Final landscaping plan shall be approved by the Department of Community Development. Seconded by Coulibaly. Mr. Fojtik asked if there was any discussion on the motion. Ms. Propp asked if Bergstrom was okay with the conditions. Mr. Lyons replied staff has not heard anything form the applicant regarding issues with the conditions. Item — GDP/SIP South of 3365 S. Washburn St. Mr. Perry stated they are always making exceptions to the 50% Class I materials requirement. He said he is on the fence with this one because the Class I materials are only in the 30% range. He stated they are constantly making exceptions and he does not want that to be the rule. Mr. Ford stated he respectfully disagrees with Mr. Perry. He said it is a logical course of action to approve the Base Standard Modification due to the previous development approvals. He stated he is usually a stickler for Class I materials but understands there is already an existing development pattern. Mr. Mitchell asked if staff was asking for anything to offset the applicant's requests. Mr. Lyons replied the applicant's overall landscaping plan exceeds base code requirements by about 25%. He said that is why staff felt comfortable with the requested Base Standard Modifications. Motion carried 9-0. Item — GDP/SIP South of 3365 S. Washburn St. SUBMIT TO: ^A City of Oshkosh Dept. of Community Development CiAr215 Church Ave., P.O. Box 1130 Planned Development Application Oshkosh(920)2365059 5 OshkoshPHONE: For General Development Plan or Specific Implementation Plan "PLEASE TYPE OR PRINT USING BLACK INK" APPLICANT INFORMATION Petitioner: Gries Architectural Group, Inc. Steve Borsecnik Date:11-06-2019 Petitioner's Address: 500 N. Commercial Street city: Neenah state: WI zip: 54956 Telephone #: (920) 722-2445 Email: sborsecnik@gries.design Contact preference: ❑ Phone X Email Status of Petitioner (Please Check): D O ner (Representative 0 Tenant - Prospective Buyer Petitioner's Signature (required): Date: 11-06-2019 OWNER INFORMATION Owner(s): Bergstrom Automotive Date: 11 -06-2019 Owner(s) Address: One Neenah Center city: Neenah State: WI Zip: 54956 l''hogerty@bergstromauto.com Telephone #: (920) 725-4444 Emal . Contact preference: ❑ Phone X Email Ownership Status (Please Check): D Individual D Trust io Partnership XCorporation Property Owner Consent: (required) By signature hereon, I/We acknowledge that City officials and/or employees may, in the performance of their functions, enter upon the property to inspect or gather other information necessary to process this application. I also understand that all meeting dates are tentative and may be postponed b he Planning Services Division for incomplete submissions or other administrative reasons. Property Owner's Signature: Date: 11 -06-2019 TYPE OF REQUEST: ❑ General Development Plan (GDP) ❑ General Development Plan (GDP) Amendment CK Specific Implementation Plan (SIP) ❑ Specific Implementation Plan (SIP) Amendment SITE INFORMATION Address/Location of Proposed Project: S. Washburn Street Proposed Project Type: Automotive Service Current Use of Property: Automotive Facility Zoning: SMU-PD Land Uses Surrounding Your Site: North: SMU-PD South: SMU-PD East: --- West: MR-12 ➢ It Is recommended that the applicant meet with Planning Services staff prior to submittal to discuss the proposal. ➢ Application fees are due at time of submittal. Make check payable to City of Oshkosh. ➢ Please refer to the fee schedule for appropriate fee. FEE IS NON-REFUNDABLE For more information please visit the City's website at www.ci.oshkosh.wi.us/Community_Development/Planning.htm Sign Staff Date Rec'o acje b SUBMITTAL REQUIREMENTS - Must accompany the application to be complete. (Submit only digital files. Please note at the discretion of Community Development staff may request a hard copy) The following information must be provided in order for the application to be considered complete and able to be scheduled for Plan Commission Review. Please use the checklist below to determine the required information to be submitted at the time of application. If all information below cannot be provided at the time of application, please request a waiver in writing to the Division's Director or designee. ❑ A General Development Plan (GDP) submittal, per Section 30-387(C)(4), shall include the following items (Submit only digital files. Please note at the discretion of Community Development staff may request a hard copy): ❑ General location map of the subject site depicting: • All lands for which the Planned Development is proposed and other lands within 100 feet of the boundaries of the subject property. • Current zoning of the subject site and abutting properties, and the jurisdiction (s) that maintains that control. • A graphic scale and north arrow. ❑ Generalized site plan showing the pattern or proposed land uses, including: • General size, shape, and arrangement of lots and specific use areas. • Basic street pattern and pattern of internal drives. • General site grading plan showing preliminary road grades. • Basic storm drainage pattern, including proposed on -site stormwater detention. • General location of recreational and open space areas, including designation of any such areas to be classified as common open space. ❑ Statistical data, including: • Minimum lot sizes in the development. • Approximate areas of all lots. • Density/intensity of various parts of the development. • Building coverage. • Landscaping surface area ratio of all land uses. • Expected staging. ❑ Conceptual landscaping plan. ❑ General signage plan. ❑ General outline of property owners association, covenants, easements, and deed restrictions. ❑ A written description of the proposed Planned Development, including: • General project themes and images. • The general mix of dwelling unit types and/or land uses. • Approximate residential densities and nonresidential intensities. • General treatment of natural features. • General relationship to nearby properties and public streets. • General relationship of the project to the Comprehensive Plan or other area plans. • Proposed exceptions from the requirements of the Zoning Ordinance. ❑ Traffic Impact Analysis (TIA), if deemed necessary by the Director of Planning Services, or designee. X A Specific Implementation Plan (SIP) submittal, per Section 30-387(C)(5), shall include the following items. Note that the area included in an SIP may be only a portion of the area included in a previously approved GDP (Submit only digital files. Please note at the discretion of Community Development staff may request a hard copy): ❑ An existing conditions map of the subject site depicting the following: • All lands for which the Planned Development is proposed and other lands within 100 feet of the boundaries of the subject site. • Current zoning of the subject property and all abutting properties, and the jurisdiction(s) that maintains that control. • Existing utilities and recorded easements. • All lot dimensions of the subject site. • A graphic scale and a north arrow. ❑ An SIP map of the proposed site showing at least the following: • Lot layout and the arrangements of buildings. • Public and private roads, driveways, walkways, and parking facilities. • Specific treatment and location of recreational and open space areas, including designation of any such areas to be classified as common open space. Page '�2 ❑ Proposed grading plan. ❑ Specific landscaping plan for the subject site, specifying the location, species, and installation size of plantings. The landscaping plans shall include a table summarizing all proposed species. ❑ Architectural plans for any nonresidential buildings, multi -family structures, or building clusters, other than conventional single-family or two-family homes on individual lots, in sufficient detail to indicate the floor area, bulk, and visual character of such buildings. ❑ Engineering plans for all water and sewer systems, stormwater systems, roads, parking areas, and walkways. ❑ Signage plan for the project, including all project identification signs, concepts for public fixtures and signs, and group development signage themes that may or may not vary from City standards or common practices. o Specific written description of the proposed SIP including: • Specific project themes and images. Specific mix of dwelling unit types and/or land uses. Specific residential densities and nonresidential intensities as described by dwelling units per acre, and landscaping surface area ratio and/or other appropriate measures of density and intensity. Specific treatment of natural features, including parkland. Specific relationship to nearby properties and public streets. • Statistical data on minimum lot sizes in the development, the precise areas of all development lots and pads; density/intensity of various parts of the development; building coverage, and landscaping surface area ratio of all land uses; proposed staging; and any other plans required by Plan Commission. • A statement of rationale as to why PD zoning is proposed. This statement shall list the standard zoning requirements that, in the applicant's opinion, would inhibit the development project and the opportunities for community betterment that are available through the proposed PD project. • A complete list of zoning standards that would not be met by the proposed SIP and the location(s) in which such exceptions/base standard modifications would occur. Phasing schedule, if more than one development phase is intended. ❑ Agreements, bylaws, covenants, and other documents relative to the operational regulations of the development and particularly providing for the permanent preservation and maintenance of common open areas and amenities. ❑ A written description that demonstrates how the SIP is consistent with the approved GDP and any and all differences between the requirements of the approved GDP and the proposed SIP. I hereby certify that to the best of my knowledge all required application materials are included with this application. I am aware that failure to submit the required completed application materials may result in denial or delay of the application request. Applicant's Signature (required):zl.� k1. &au4,p Date: 11-06-2019 Gries Architectural Group Inc. November 20, 2019 PROJECT NARRATIVE Bergstrom Auto Body 1. Proposed use of property: New building for an Auto Body Shop. 2. Existing use of property: The existing area for construction of the new building was agricultural. 3. Identification of new structure: Bergstrom Body Shop. 4. Compatibility of adjacent properties: New construction will occur in a semi - developed area where properties currently are Zoned PD to the north and south, property to the west is Zoned A-1 Agribusiness and to the east is Zoned L-1 Light Industrial. 5. Traffic generation. Will increase due to new business activity. Access will be one entrance drive off of S. Washburn Street. 6. Hours of Operation: lam — 8pm, Monday — Friday, lam — 6pm, Saturday. 7. Proposed site construction overview: a. Construction of a new Auto Body Shop. b. A new building, site lighting, landscaping, paved parking area and retention ponds are proposed. 8. Exterior Materials: The front and front portions of the side facades will include Class I materials. ACM (aluminum composite material) panels (with concealed fasteners) will be used as an alternate Class I material, which is visually compatible with the neighboring buildings in the area. The back portions of the side facades as well as the rear facade will be precast concrete wall panels. The use of precast concrete wall panels are proposed at the Service Area (no street frontage facades) to be used in lieu of split -faced CMU, as an economical alternate, to meet the requirements of the State Energy Code. The State Energy Code was revised to include continuous insulation at exterior walls. Single-wythe split -face CMU does not meet the continuous insulation requirement. Precast wall panels do meet the state's requirements for continuous insulation. Wall panel finish will have similar appearance to the split -face CMU. 500 North Commercial Street Neenah, WI 54956 Phone: 920-722-2445 Fax: 920-722-6605 Page 9 Gries Architectural Group Inc. 9. Parking: 133 parking stalls allowed per code. 39,744 s.f. divided by 1 space per 300 s.f. gross floor area = 133 parking stalls. Additional parking stalls exceeding the maximum allowed by code are provided for vehicle inventory, service, employee parking and customer parking. "Please refer to Site Plan Submittal and Application for additional information. 500 North Commercial Street Neenah, WI 54956 Phone:920-722-2445 Fax:920-722-6605 Page 10 NIGNOIDGIM HGO>WGO soil[) �__- - --_-------------------------- DETENTION GYEBP.ULfNLIFL➢ a..npnwu.wuwx imuu.0 muua� corn � 9II scucr[ owrvaohua hueyauv oeinao o6u 6a re iambic B+t�uxii...�Vc'camo-' yM AR Nry��q am M1iw.ws'hrwtee' aro-raa+e oPa.elw'uu,' dW ..Paves cuw�w auawuc � '� ffi .�nn�e�unpa4nm f iunoinumaa y �� 91Y 6BE�4tlN60 xer Po..wewu cemrryuivaeenme xenre.uur tour pp amouryry epo j H� nuaune err / �Irvryi1V4PVF�Ni�{LM�(Yw.�a'uawt�tdWssueaub��l�, p?". 9tlJd e13YCM JAY+]5 �� �C�� � x .�.� .. PROPOSED WILDING .wr....FT' DETENTION I wn a m a h WSA D/F ILLUMINATED PYLON (Qty 1) SQUARE FOOTAGE: 489.5 FIELD SURVEY REQUIRED JoBn:247061-RD REV I oaE sr o-R-1 CLIENTAPPROVAL DATE BERGSTROM SHEETNUMBER m, ,> JONES SIGN Your Vision, Accomplished. DATE-11.2021)19 £IaNER: M.BEHRLE oa n Iaa,ah x express.cars by BERGSTROM AUTOMOTIVE TBD S Washleum St, Oshkosh, WI 54904 next l0 3365 S Washhum St, Oshkosh, WI549D4 a LANDLORD APPROVAL DATE DO Pf IASE: CONCEPTUAL WW W .JONESSIGN.COM SP.LE`u REP. J. MORTENSEN PROJ MG : C, KIDDSIGN This uurlgical.unpublished drawing by Jones Sign Co..Inc. It ia(or your personal use in conlunclion withaprolect being piannodloryopbyJONESSIGN. It is not to ba shown to onyone outside of your orgunixa to bo uuetl. repmducad, copied or exhibited in any faahion_Usa of this design or the aaliont elements of this design in any siyn done by any otM1ar company. without the oxpmss written pormi^..ion JONES SIGN. Is Wood- by Ines no carrion a 60 Wei— of up Io 2596 of Iho purch— pries of the sign. JONES SIGN WWI ondoavor to closely match colors, including PMS. where xpecilled. Wp ewtnot guarantor exact ma chusldue to varying compatibility of ..dace Inatudels end paints uacd. All sixes and dimensions aro Illusumed lot chon[s conception of plgeet and — not to bo undorsteod ea being exact aixo or exec[ sca d ■■ rva+ o i Off-mmeemml S I E'<TER1OR FINISH KEY NOTES KEY N01'9 -TM- SUMMARY KEY NOTE MATERIAL SUMMARY KEY NOTE MATERIAL -MARy KEY NOTE M.-- -M- T.O. WALL ----------- - - --- - - n EAST ELEVATION (4PARTIAL NORTH ELEVATION - 5 (9 PARTIAL NORTH ELEVATION - A QNORTH ELEVATION llRSTi-A - "I FIRST 1, (n WEST ELEVATION (gPARTIAL SOUTH ELEVATION - A (,qii, PARTIAL 50L)TH ELEVATION - 5 ( ------------------ FiO- SERVICE T.O. WILL I1 ---------- �4 - -,x� QSOUTH ELEVATION _FIRST FU�---k, —100. - 0., GDP/SIP BERGSTROM FOX VALLEY INC BERGSTROM OF THE FOX VALLEY INC 0 S WASHBURN ST PO BOX 777 1 NEENAH CENTER FL 7 PC: 12-03-19 NEENAH WI 54957 NEENAH WI 54956 HUNTERS RIDGE OF OSHKOSH LLC 2990 UNIVERSAL ST STE C OSHKOSH WI 54904 TOWN OF NEKIMI 3790 PICKETT RD OSHKOSH WI 54904 GRIES ARCHITECTURAL GROUP INC ATTN: STEVE BORSECNIK 500 N COMMERCIAL ST NEENAH WI 54945 MIDWEST REAL ESTATE DEVELOPMENT 3 LLC 2990 UNIVERSAL ST STE C OSHKOSH WI 54904 WITTMAN AIRPORT OSH 525 W 20TH AVE OSHKOSH WI 54902 NORTHERN REAL ESTATE INVESTMENTS LLC 5711 GREEN VALLEY RD OSHKOSH WI 54904 BERGSTROM PROPERTIES INC 1 NEENAH CTR NEENAH WI 54956 Page 18 N m70 r; t RITE-TAIL-L-A � k .c . _ ...._. ........__....._.__...... .............' --INSIIRANCE1NAif �. ID o rn Y, € t a, cn 7 CD 5 � ' gl ,"'i cn co co o o C) M Ch -WASHBWR-N-S Oshkosh City Limit Ndl I ADBER-EZNY-RD y 7C" __-.- _..__� 1ST EAA-S;T t II t` fir` _ Fr r R r �:a a8a a 4 ! `V®®�' P .,:, � !F ••. QQ tl 4I 11 Phi: F€[Iffe r f r a ��� €�r`[rf.rrF��F � `� B. �A• _ �, ��aQQg,��a �� >, FIAM F Pr i I-F. 1r rMv rf? -F, n ." � 3 R � a eR� ilea semis � mac« i > €" �. .,.f is ..« '` a ::a -- Pt e 7' � � � 7. . _ rj �Rg F � t � City of Oshkosh maps and data are intended to be used for general identification purposes only, and the City of Oshkosh assumes no liability for the accuracy of the information. Those using the information are responsible for verifying accuracy. For full disclaimer please go to www.ci.oshkosh.wi.us/GlSdisclaimer N 1 in=0.05mi 1 in = 250 ft Printing Date: 11/8/2019 Prepared by: City of Oshkosh, WI In VV Oshkosh