Loading...
HomeMy WebLinkAbout0102822-BuildingOSHKOSH ON THE WATER Job Address 1140 LAAGER LN Designer Category Type Zoning CITY OF OSHKOSH BUILDING PERMIT - APPLICATION AND RECORD Owner STEVEN S/PEGGYTROUDT Contractor 111 - Single Family Addition · Building (~ Sign Unfinished/Basement 0 Sq. Ft. Finished/Living 0 Sq. Ft. Garage 0 Sq. Ft. Foundation · Poured Concrete (~ Floating Slab (~ Concrete Block (~) Post Occupancy Permit Required Park Dedication Create Date TOM WILLIAMS BUILDING CONTRACTOR No 0102822 07/09/2003 O Canopy O Fence (~)Raze Class of Const: Rooms 0 Bedrooms 0 Baths 0 (~ Pier (~) Treated Wood Flood Plain # Dwelling Units Plan Other Height Stories 0 Ft. Height Permit 0 # Structures 0 Size [] Projection Canopies Signs 0 0 Use/Nature of Work SFPJ Constructing a 18'x18' family room addition on the rear of the house. HVAC Contractor Electric Contractor Fees: Valuation Issued By: MARX MECHANICAL WITZKE ELECTRIC $30,000.00 Plan Approval Plumbing Contractor $40.00 Permit Fee Paid $125.00 Park Dedication $0.00 Date 07/14/2003 Final/O.P. 00/00/0000 [] Permit Voided J In the performance of this ~~-"~l~vor/~rules governing the described construction. Signature Date Jr,_ ~' ~ Agent/Owner Address 501 IOWA STREET OSHKOSH WI 54902 - 0000 Telephone Number 233-7817 Plot Plan For: Steve & Peggy Troudt 1140 Laager La. Oshkosh, WI 54902 80' 31.04' 49,04' 43' 6' New 4862 57' Scapewell 131.73' 4' 1" 132.04' 38' Existing House 58' 33' 24' 25' N "~ 80' W+ City Sidewalk S Scale- 1/16"= 1'0" Drawn By T.W, 7-8-03 ,)' 80 0' )' 80.0' 83. )' 80.0' 8~ o,sc~,~ ~__N tlleaSUrVCYarea and it is not intended to be used as one.~ ~ ~ ' ~ ~~[ ~ ..~ ,.,o~,,o. ,o~.,~a ~. ~,o~ ¢,,y, ~o~ty Ci~ of Oshkosh Wisconsin shown ~nd it is ,o b~ use0 for rCf, re,,~e ~O~Un~z ~eve'o~men* O~HKO/H >urposes only. The City of Oshkosh is not re- 1" 20' City or Oshkosh. Created ey- ~L~ 07/08/03 '. ME 22 09 1 1 < 4 k4,' 4 .k.'N • 2 cG z O z :c :a f:4 �'- G ,' p zao u o� �=� z z - v) 0 0 =� w < zC w w ° z U 7 Z � z m � 1 t `.� �, < <� t. . qt ? >.... 1 1 ' 111� co O U u c aC J �� �� /� N re: � 4A 8 .0 u -°, ; / G H N - — c :::.... , flfl n 1r; 0 ,... 0 0 ' \ \ .:. ' A r / i 1 11------ - 1 71 Z. � ..= � N . I I yr r a L a`ni y >-, .— N v �" 3-oNE v 0.) • c A .. .o ` . C l l\ . mi l' • ..c - o 45 .n c 1 �S�j ` ',E5 i ( ��`(� " \ , � 7��}' , ` 111 ` 1 V e �� `` C � 3 . z; a� y = el NI .. _ 1 z Lt z LLi . i F- U Gr z � .. vi Lli vc -0 - a > n. >- cc t C 1 E- r" u.1 5 di cn = O Lt1 v c ti; c. _.1 _ F- : < it < to E- C4 cn °- U O _ _ c • > r 2 c v? > c��C7.... � >tL] wUcY.< ¢= z a > z 7_ U E L. a•N u•-• Zcnz 'z� z Oz > -.1 0th -. E- F-OF.c4 t= co'c•= ?,,f (=ts. ci.u. 1 �GF -Uu.1 i `-d c n c / ) .Y'- aU -7 --1 -7 ^c4 C Lt.) E-- s -0 € �' woo zL)< — < X X < - zLi.) -� c.) Dew- 1 <<r -' .-J 0 3 tL 3 aad > cCcr =ou» <w > ww .. < <u. v)E-0 u.? u, u.aa,Oc ^cot:.. LJ E-- 0 z - 1996- 20-46- Troudt Gable Wall Inside Elevation AJ:' elh • Q ❑ Q 4'101/2" 7'3" 4'101/2" 6 1, Mote: AVM dknonsh3ns shown 6" ere funIshod dimonslons. 18' Drawn By T.W. 7 -9 -03 Remove existing patio door and relocate to addition. Case opening and finish with trim to match existing on both sides. 2161/2" Addition For: Steve & Peggy Troudt 1140 Laager La. Oshkosh, Wi 54902 4'01 /16" FS108 with EDL step flashing R.O.= 211/2 "x551/2" --------------- ............. I ................... FS 108 with EDL step flashing R.O.— 211/2 "x551/2" CW245 - R.O. _ 4'93/8 "x4'53/8 ". Glass on this unit only to be tempered. 9'63/8" CW245 -2 - R.O. _ 9'63/8 "x4'53/8" Reuse existing patio door. R.O. = 6'2"x6'101/2". Verify by checking existing opening. .. ............................... .............. ' ....... FS108 with EDL step flashing R.O.= 211/2 "x551 /2" 4'59/16" CW 14xCTCW 1 - R.O. = 2'47/8 "x5'51 /8" 1'$13/16" 2'47/8" Lay roof trusses out from this end of addition FS108 with EDL step flashing R.O. = 211/2 "x551/2" Note: Frame opening to dimensions as specified by fireplace manufacturer. 2'03/4" 3'01/2" b j 2'03/4" Continental 1'35/16 "I _ 7 1 2 " CW14xCTCW1 - R.O. = 2'47/8 "x5'51/8" 1'35/16 "1 , 1 1'813/16" 4'93/8" Note: Windows to be Andersen 400 series casements with screens and terratone exterior. Hardware to be Metro stone finish. Jamb depth to be 65/8 ". Glass to be High Performance Low E. Siding and shingles to match existing. Exterior walls to be 2x6 with 1/2" osb sheathing and Tyvek. 1'61/8" 18' Floor framing to be I joists as required for clear span. Depth to be 91/2" if possible. Increase series and use 12" centers If necessary to obtain 91/2" depth. Interior walls & telling to be Kalcore with thin coat plaster. Interior trim to match existing. Fireplace wall to be determined. 6'2" Floor finish to be determined. Trusses to be parallel chord. Provide a #4862 -66 scapewell at west wall of existing house per estimate. Window to be Andersen slider G536 -T -HP with screen, hardware to be stone Metro. Window R.O.= 5'0 "x3'6 ". Masonry opening= 5'6 "x4'0 Jamb depth to be 49/16 ". Clear opening of window shall be no greater than 44" from concrete basement floor. Layout opening to meet this requirement before cutting concrete. N W E S Drawn By T.W. 6 -12 -03 Scale 112" = 1'0" 7/11/2003 3:40 PM FROM: 9202353061 TO: +1 (920) 236 -5084 PAGE: 001 OF 004 Permit Number REScheck Compliance Certificate Checked By/Date Wisconsin Uniform Dwelling Code REScheckSoftware Version 3.5 Release lc Data filename: C:\Program Files \Check\REScheck \TOMWILLIAMSTROUDT.rck COUNTY: Winnebago HEATING TYPE: Non - Electric DATE: 07/11/03 UDC COMPLIANCE: Passes Code - Allowed UA = 100 Your Home UA = 98 2.0% Better Than Code (UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R -Value R -Value U- Factor UA Ceiling 1: Cathedral Ceiling (no attic) 396 49.0 0.0 8 Skylight 1: Wood Frame:Double Pane with Low -E 33 0.350 12 Wall 1: Wood Frame, 16" o.c. 540 25.0 0.0 21 Window 1: Above - Grade:Wood Frame :Double Pane with Low -E 84 0.330 28 Window 2: Above - Grade:Wood Frame:Double Pane with Low -E 17 0.340 6 Door 1: Glass 40 0.310 12 Basement Wall 1: Solid Concrete or Masonry 216 0.0 14.4 11 Wall height: 4.0' Depth below grade: 3.5' Insulation depth: 4.0' Furnace 1: Forced Hot Air, 93 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the Wisconsin Uniform Dwelling Code requirements in RES check Version 3.5 Release I c (formerly MECcheclR and to comply with the mandatory requirements listed in the RES checklnspection Checklist. Builder/Designer Date Heating Equipment Sizing Suwnmary General Information Outdoor Design Temperature: -15 deg Conditioned Floor Area: 648 ft2 Average Ceiling Height: 7.5 ft Infiltration Rate: 0.50 Normalized ACH Equipment Oversizing Factor: 15.0 % Loads Summary Conductive Losses: 8333 Btu/hr 7/11/2003 3:40 PM FROM: 9202353061 TO: +1 (920) 236 -5084 PAGE: 002 OF 004 Infiltration Losses: 3718 Btu/hr Oversizing Factor Losses: 1808 Btu/hr Total Building Heating Load: 13859 Btu/hr 7/11/2003 3:40 PM FROM: 9202353061 TO: +1 (920) 236 -5084 PAGE: 003 OF 004 REScheck Inspection Checklist Wisconsin Uniform Dwelling Code REScheckSoftware Version 3.5 Release lc DATE: 07/11/03 Bldg. Dept. Use Ceilings: [ j 1. Ceiling 1: Cathedral Ceiling (no attic), R-49.0 cavity insulation Comments: Above -Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c., R -25.0 cavity insulation Comments: Basement Walls: [ ] 1. Basement Wall 1: Solid Concrete or Masonry, 4.0' ht/3.5' bg/4.0' insul, R -14.4 continuous insulation Comments: Windows: [ ] I. Window 1: Above - Grade:Wood Frame:Double Pane with Low -E, U- factor: 0.330 Windows must be labeled and rated in accordance with NFRC or must use default values from COMM Table 22.05 -1. # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ] 2. Window 2: Above - Grade:Wood Frame:Double Pane with Low -E, U- factor: 0.340 Windows must be labeled and rated in accordance with NFRC or must use default values from COMM Table 22.05 -1. # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Skylights: [ ] 1. Skylight 1: Wood Frame:Double Pane with Low E, U- factor: 0.350 For skylights without labeled U- factors, describe features: # Panes_ Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: [ ] 1. Door 1: Glass, U- factor: 0.310 Doors must be Labeled and rated in accordance with NFRC or must use default values from COMM Table 22.05 -2. Comments: Heating and Cooling Equipment: [ j 1. Furnace 1: Forced Hot Air, 93 AFUE or higher Make and Model Number • Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate air -tight assembly (COMM 22.32). Ventilation: 7/11/2003 3:40 PM FROM: 9202353061 TO: +1 (920) 236 -5084 PAGE: 004 OF 004 [ ] Mechanical ventilation systems must be balanced. Passive intake air ducts providing makeup air for intermittent exhaust must be sized to provide a minimum of 40% of the total air that would be exhausted with all the intermittent exhaust ventilation in the dwelling operating simultaneously (COMM 23.02(3)(b)). Vapor Retarder: [ ] Required on the warm -in- winter side of all framed ceilings, walls, and floors (COMM 22.22). Materials Identification: [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R- values, glazing U- factors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to a minimum of R -5 (COMM 22.17). Duct Construction: [ ] Sections of ducts in unconditioned spaces and the unconditioned side of plenums must be sealed (COMM 22.18). Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided (COMM 22.15). Humidity Control: [ ] A humidistat is required when humidifying or dehumidifying (COMM 22.16). Pipe Insulation: [ ] All heating pipes in unheated spaces and all cooling pipes in uncooled spaces must be insulated with a material providing a minimum thermal resistivity of R -4 (COMM 22.19). NOTES TO FIELD (Building Department Use Only)