HomeMy WebLinkAbout0102822-BuildingOSHKOSH
ON THE WATER
Job Address 1140 LAAGER LN
Designer
Category
Type
Zoning
CITY OF OSHKOSH
BUILDING PERMIT - APPLICATION AND RECORD
Owner STEVEN S/PEGGYTROUDT
Contractor
111 - Single Family Addition
· Building (~ Sign
Unfinished/Basement 0 Sq. Ft.
Finished/Living 0 Sq. Ft.
Garage 0 Sq. Ft.
Foundation · Poured Concrete (~ Floating Slab
(~ Concrete Block (~) Post
Occupancy Permit Required
Park Dedication
Create Date
TOM WILLIAMS BUILDING CONTRACTOR
No 0102822
07/09/2003
O Canopy O Fence (~)Raze
Class of Const:
Rooms 0
Bedrooms 0
Baths 0
(~ Pier
(~) Treated Wood
Flood Plain
# Dwelling Units
Plan
Other
Height
Stories
0 Ft.
Height Permit
0 # Structures 0
Size
[] Projection
Canopies
Signs
0
0
Use/Nature
of Work
SFPJ Constructing a 18'x18' family room addition on the rear of the house.
HVAC Contractor
Electric Contractor
Fees: Valuation
Issued By:
MARX MECHANICAL
WITZKE ELECTRIC
$30,000.00 Plan Approval
Plumbing Contractor
$40.00 Permit Fee Paid $125.00 Park Dedication $0.00
Date 07/14/2003 Final/O.P. 00/00/0000
[] Permit Voided J
In the performance of this ~~-"~l~vor/~rules governing the described construction.
Signature Date
Jr,_ ~' ~ Agent/Owner
Address 501 IOWA STREET OSHKOSH WI 54902 - 0000 Telephone Number
233-7817
Plot Plan For:
Steve & Peggy Troudt
1140 Laager La.
Oshkosh, WI 54902
80'
31.04'
49,04'
43'
6' New 4862 57'
Scapewell
131.73' 4' 1" 132.04'
38' Existing House
58'
33'
24'
25'
N "~ 80'
W+ City Sidewalk
S Scale- 1/16"= 1'0" Drawn By T.W,
7-8-03
,)' 80 0'
)' 80.0' 83.
)' 80.0' 8~
o,sc~,~ ~__N
tlleaSUrVCYarea and it is not intended to be used as one.~ ~ ~ ' ~ ~~[ ~
..~ ,.,o~,,o. ,o~.,~a ~. ~,o~ ¢,,y, ~o~ty Ci~ of Oshkosh Wisconsin
shown ~nd it is ,o b~ use0 for rCf, re,,~e ~O~Un~z ~eve'o~men* O~HKO/H
>urposes only. The City of Oshkosh is not re- 1" 20'
City or Oshkosh. Created ey- ~L~ 07/08/03
'. ME 22 09
1 1 < 4 k4,' 4
.k.'N • 2
cG z O z
:c :a f:4 �'- G ,' p
zao u o� �=�
z z - v) 0 0
=� w < zC w w ° z
U 7
Z � z m � 1 t
`.� �, < <� t. . qt
? >....
1 1 ' 111� co
O
U u c aC J �� �� /�
N re: �
4A 8 .0 u -°, ; /
G H N - — c :::....
, flfl
n
1r; 0 ,... 0 0 ' \ \ .:. ' A r / i 1 11------ - 1 71 Z.
� ..= � N . I I yr
r a L a`ni y >-, .—
N v
�" 3-oNE v
0.) • c A .. .o ` . C l l\ . mi l' •
..c - o 45 .n c 1 �S�j `
',E5 i ( ��`(� " \ , � 7��}' , ` 111 ` 1 V e �� `` C � 3 .
z; a� y = el NI .. _ 1 z Lt z LLi . i F- U Gr z � .. vi Lli vc -0 - a > n. >- cc t C
1 E- r" u.1 5 di cn = O Lt1 v c
ti; c. _.1
_ F- : < it < to E- C4 cn °- U O _ _ c
• > r 2 c v? > c��C7.... � >tL] wUcY.< ¢= z a > z 7_ U
E L. a•N u•-• Zcnz 'z� z Oz > -.1 0th -. E- F-OF.c4 t=
co'c•= ?,,f (=ts. ci.u. 1 �GF -Uu.1 i `-d c n c / ) .Y'- aU -7 --1 -7 ^c4 C Lt.) E--
s -0 € �' woo zL)< — < X X < - zLi.) -� c.) Dew- 1 <<r -' .-J 0
3 tL 3 aad > cCcr =ou» <w > ww .. < <u. v)E-0 u.? u, u.aa,Oc ^cot:..
LJ
E--
0
z
- 1996- 20-46-
Troudt Gable Wall
Inside Elevation
AJ:' elh
•
Q ❑ Q
4'101/2" 7'3" 4'101/2"
6 1,
Mote: AVM dknonsh3ns shown
6"
ere funIshod dimonslons.
18'
Drawn By T.W.
7 -9 -03
Remove existing patio door and
relocate to addition. Case opening
and finish with trim to match existing
on both sides.
2161/2" Addition For: Steve & Peggy Troudt
1140 Laager La. Oshkosh, Wi 54902
4'01 /16"
FS108 with EDL
step flashing R.O.=
211/2 "x551/2"
---------------
............. I ...................
FS 108 with EDL
step flashing R.O.—
211/2 "x551/2"
CW245 - R.O. _
4'93/8 "x4'53/8 ".
Glass on this unit
only to be tempered.
9'63/8"
CW245 -2 - R.O. _
9'63/8 "x4'53/8"
Reuse existing
patio door. R.O.
= 6'2"x6'101/2".
Verify by checking
existing opening.
.. ...............................
.............. ' .......
FS108 with EDL
step flashing R.O.=
211/2 "x551 /2"
4'59/16"
CW 14xCTCW 1 - R.O.
= 2'47/8 "x5'51 /8"
1'$13/16" 2'47/8"
Lay roof trusses out
from this end of addition
FS108 with EDL
step flashing R.O. =
211/2 "x551/2"
Note: Frame opening to
dimensions as specified
by fireplace manufacturer.
2'03/4" 3'01/2" b j 2'03/4"
Continental
1'35/16 "I _ 7 1 2 "
CW14xCTCW1 - R.O.
= 2'47/8 "x5'51/8"
1'35/16 "1 , 1 1'813/16"
4'93/8" Note: Windows to be Andersen 400 series
casements with screens and terratone exterior.
Hardware to be Metro stone finish. Jamb depth
to be 65/8 ". Glass to be High Performance Low E.
Siding and shingles to match existing.
Exterior walls to be 2x6 with 1/2" osb sheathing
and Tyvek.
1'61/8"
18' Floor framing to be I joists as required for clear span.
Depth to be 91/2" if possible. Increase series and use
12" centers If necessary to obtain 91/2" depth.
Interior walls & telling to be Kalcore with thin
coat plaster.
Interior trim to match existing.
Fireplace wall to be determined.
6'2"
Floor finish to be determined.
Trusses to be parallel chord.
Provide a #4862 -66 scapewell at west wall of existing
house per estimate. Window to be Andersen slider
G536 -T -HP with screen, hardware to be stone Metro.
Window R.O.= 5'0 "x3'6 ". Masonry opening= 5'6 "x4'0
Jamb depth to be 49/16 ". Clear opening of window shall
be no greater than 44" from concrete basement floor.
Layout opening to meet this requirement before cutting
concrete.
N
W E
S
Drawn By T.W. 6 -12 -03
Scale 112" = 1'0"
7/11/2003 3:40 PM FROM: 9202353061 TO: +1 (920) 236 -5084 PAGE: 001 OF 004
Permit Number
REScheck Compliance Certificate Checked By/Date
Wisconsin Uniform Dwelling Code
REScheckSoftware Version 3.5 Release lc
Data filename: C:\Program Files \Check\REScheck \TOMWILLIAMSTROUDT.rck
COUNTY: Winnebago
HEATING TYPE: Non - Electric
DATE: 07/11/03
UDC COMPLIANCE: Passes
Code - Allowed UA = 100
Your Home UA = 98
2.0% Better Than Code (UA)
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R -Value R -Value U- Factor UA
Ceiling 1: Cathedral Ceiling (no attic) 396 49.0 0.0 8
Skylight 1: Wood Frame:Double Pane with Low -E 33 0.350 12
Wall 1: Wood Frame, 16" o.c. 540 25.0 0.0 21
Window 1: Above - Grade:Wood Frame :Double Pane with Low -E 84 0.330 28
Window 2: Above - Grade:Wood Frame:Double Pane with Low -E 17 0.340 6
Door 1: Glass 40 0.310 12
Basement Wall 1: Solid Concrete or Masonry 216 0.0 14.4 11
Wall height: 4.0'
Depth below grade: 3.5'
Insulation depth: 4.0'
Furnace 1: Forced Hot Air, 93 AFUE
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the Wisconsin
Uniform Dwelling Code requirements in RES check Version 3.5 Release I c (formerly MECcheclR and to comply with the mandatory
requirements listed in the RES checklnspection Checklist.
Builder/Designer Date
Heating Equipment Sizing Suwnmary
General Information
Outdoor Design Temperature: -15 deg
Conditioned Floor Area: 648 ft2
Average Ceiling Height: 7.5 ft
Infiltration Rate: 0.50 Normalized ACH
Equipment Oversizing Factor: 15.0 %
Loads Summary
Conductive Losses: 8333 Btu/hr
7/11/2003 3:40 PM FROM: 9202353061 TO: +1 (920) 236 -5084 PAGE: 002 OF 004
Infiltration Losses: 3718 Btu/hr
Oversizing Factor Losses: 1808 Btu/hr
Total Building Heating Load: 13859 Btu/hr
7/11/2003 3:40 PM FROM: 9202353061 TO: +1 (920) 236 -5084 PAGE: 003 OF 004
REScheck Inspection Checklist
Wisconsin Uniform Dwelling Code
REScheckSoftware Version 3.5 Release lc
DATE: 07/11/03
Bldg.
Dept.
Use
Ceilings:
[ j 1. Ceiling 1: Cathedral Ceiling (no attic), R-49.0 cavity insulation
Comments:
Above -Grade Walls:
[ ] 1. Wall 1: Wood Frame, 16" o.c., R -25.0 cavity insulation
Comments:
Basement Walls:
[ ] 1. Basement Wall 1: Solid Concrete or Masonry, 4.0' ht/3.5' bg/4.0' insul,
R -14.4 continuous insulation
Comments:
Windows:
[ ] I. Window 1: Above - Grade:Wood Frame:Double Pane with Low -E, U- factor: 0.330
Windows must be labeled and rated in accordance with NFRC or must use default values
from COMM Table 22.05 -1.
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
[ ] 2. Window 2: Above - Grade:Wood Frame:Double Pane with Low -E, U- factor: 0.340
Windows must be labeled and rated in accordance with NFRC or must use default values
from COMM Table 22.05 -1.
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Skylights:
[ ] 1. Skylight 1: Wood Frame:Double Pane with Low E, U- factor: 0.350
For skylights without labeled U- factors, describe features:
# Panes_ Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Doors:
[ ] 1. Door 1: Glass, U- factor: 0.310
Doors must be Labeled and rated in accordance with NFRC or must use default values
from COMM Table 22.05 -2.
Comments:
Heating and Cooling Equipment:
[ j 1. Furnace 1: Forced Hot Air, 93 AFUE or higher
Make and Model Number •
Air Leakage:
[ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] Recessed lights must be type IC rated and installed with no penetrations or installed inside
an appropriate air -tight assembly (COMM 22.32).
Ventilation:
7/11/2003 3:40 PM FROM: 9202353061 TO: +1 (920) 236 -5084 PAGE: 004 OF 004
[ ] Mechanical ventilation systems must be balanced. Passive intake air ducts providing makeup air
for intermittent exhaust must be sized to provide a minimum of 40% of the total air that would be
exhausted with all the intermittent exhaust ventilation in the dwelling operating simultaneously
(COMM 23.02(3)(b)).
Vapor Retarder:
[ ] Required on the warm -in- winter side of all framed ceilings, walls, and floors (COMM 22.22).
Materials Identification:
[ ] Materials and equipment must be identified so that compliance can be determined.
[ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] Insulation R- values, glazing U- factors, and heating equipment efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation:
[ ] Ducts in unconditioned spaces must be insulated to a minimum of R -5 (COMM 22.17).
Duct Construction:
[ ] Sections of ducts in unconditioned spaces and the unconditioned side of plenums must be sealed
(COMM 22.18).
Temperature Controls:
[ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially
restrict or shut off the heating and/or cooling input to each zone or floor shall be provided
(COMM 22.15).
Humidity Control:
[ ] A humidistat is required when humidifying or dehumidifying (COMM 22.16).
Pipe Insulation:
[ ] All heating pipes in unheated spaces and all cooling pipes in uncooled spaces must be
insulated with a material providing a minimum thermal resistivity of R -4 (COMM 22.19).
NOTES TO FIELD (Building Department Use Only)