HomeMy WebLinkAbout0106136-BuildingOSHKOSH
ON THE WATER
.lob.Address 1370 JUDY LEE CT
Designer
CITY OF OSHKOSH
BUILDING PERMIT - APPLICATION AND RECORD
Owner RUSCH HOMES LLC
Contractor RUSCH HOMES LLC
Category 110 - New Single Family
No 106136
Create Date 01/14/2004
Plan F1-005-0104R
Type I(~ Building (~ Sign (~ Canopy (~ Fence (~ Raze
Zoning R-1 Class of Const: 8 Size IRRG
Unfinished/Basement 730 Sq. Ft. Rooms 7 Height 22 Ft. ~J Projection
Finished/Living 1879 Sq. Ft. Bedrooms 4 Stories 2 Canopies
Garage 731 Sq. Ft. Baths 3 Signs
Foundation O Poured Concrete ~ Floating Slab ~ Pier ~ Other
~ Concrete Block ~ Post ~ Treated Wood
Occupancy Permit Required Flood Plain No Height Permit Not Required
Park Dedication Required # Dwelling Units 1 # Structures 1
Use/Nature NSFR/ New single family 2 story, 3 car attached garage, 14' x 14' patio. Driveway shall not exceed 24' wide at the front property line.
of Work
HVAC Contractor CONDON TOTAL COMFORT Plumbing Contractor HANSON QUALITY PLUMBING
Electric Contractor CUMINGS ELECTRIC INC
Fees: Valuation $100,000.00 Plan Approval $75.00 Permit Fee Paid $409.00 Park Dedication $200.00
Issued By: Date 01/21/2004 Final/O.P. 00/00/0000
Permit Voided
Parcel Id # 1343650000
In the performance of this work I agree to perform all work pursuant to rules governing the described construction.
While the City of Oshkosh has no authority to enforce easement restrictions of which it is not a party, if you perform the work
described in this permit application within an easement, the City strongly urges the permit applicant to contact the easement
holder(s) and to secure any necessary approvals before starting such activity.
Signature Date
Agent/Owner
Address P O BOX 423 Omro WI 54963 - 0000 Telephone Number 685-0241
To schedule inspections please call the Inspection Request line at 236-5128 noting the Address, Permit Number, Type of
Inspection (i.e. Footing, Service, Final, etc.), Access into Building if Secure (how do we gain entry), your Name and Phone
Number. Unless specified otherwise, we will assume the project is ready at the time the request is received. Work may
continue if the inspection is not performed within two business days from the time the project is ready.
Wisconsin Department of Industry, WISCONSIN UNIFORM Application No.
Labor and Human Relations
Safety and Buildings Division BUILDING PERMIT 0106136
P.e. Box 2509 APPLICATION Parcel No.
Madison, WI 53701-2509
Wisconsin Statues 101.63, 101.73
[] Constr [] HVAC [] Elec [] Plbg [] Erosion [] Other:
Owner's Name Mailing Address Telephone No.
RUSCH HOMES LLC PO BOX 423 eMRe WI 54963 - 0000
Contractor: L~J Con~J Elec~J HVAC ~J Plbg Lic/Cert # Mailing Address Telephone No.
RUSCH HOMES LLC 000000 P e BOX 423 emro WI 54963 - 0 685-0241
Contractor: ~J Con ~J Elec~J HVAC~J Plbg Lic/Cert # Mailing Address Telephone No.
CUMINGS ELECTRIC INC 170792 PO BOX749 NEENAH WI 54957 - 749 920-722-1240
Contractor: ~J Con ~J Elec~J HVAC [] Plbg Lic/Cert # Mailing Address Telephone No.
CeNDeN TOTAL COMFORT 3202 PO BOX 184 RIPEN W 54971 - 184 920-748-5050
Contractor: ~J Con [] Elec [] HVAC [] Plbg bio/Cart # Mailing Address Telephone No.
HANSON QUALITY PLUMBING 550 N BLUEMOUND RD APPLETON WI 54914 - 0 730-0205
I Lot Area Sq. ft. 1/4, 1/4, Section , T N, R E(or)W
Building Address Subdivision Name Lot No. Block No.
1370 JUDY LEE CT 4th Add't Westleigh Farms 214
Zoning District(s) lZoning Permit No. Front Rear Left Right
J __Setbacks ft ......... _f_t_: ft ft
, .,.,~= ~=u~,~E. --~ ~r~-,, ~ ..............................
L~J New [] Repair [] Single Family Entrance Panel L~J Forced Air Furnace Fuel Nat. L.P. Oil Elec. Solid Sola
[] Alteration [] Raze [] Two Family Size: 200 amp [] Radiant Baseboard or Panel Gas ,
[] Addition [] Garage Service: [] Heat Pump Space Htg [] [] [] [] [] []
[] Move [] Other (print): [] Overhead
[] Boiler Water Htg [] [] [] [] [] []
[] Other: [] Underground [] Central Air Conditioning * ~J Dwelling unit will have 3 kilowatt or
] 8~l~,lS~ ~Y~E ~ f~OND~ION [] Other = more installed electric space heating equip.
[] Site Constructed · Concrete - Infiltration control option is: [] Full sealing
Unfinished [] Manufactured · Masonry Sewer of joints. [] Blower door test. [] Exterior
Basement 730 Sq. ft. S 8~IES · Treated Wood [] Municipal air infiltration barrier.
Living Area 1879 Sq. ft. [] 1-Story · Other [] Septic
[] 2-Story Permit No. Envelope 28610 BTU/HR
Garage 731 Sq. ft. [] Other [] Seasonal Infiltration 15967 BTU/HR
[] Permanent [] Municipal Utility
[] Plus Basement [] Other [] Private On-Site Well $130,000.00
The applicant agrees to comply with all applicable codes, statues and ordinances and with the conditions of this permit, understands that the issuance of
the permit creates no legal liability, express or implied, on the Department or municipality; and certifies that all the above information is accurate.
APPLICANT'S SIGNATURE DATE SIGNED
This permit is issued pursuant to the following conditions. Failure to comply may result in suspension or
APPROVAL CONDITIONS
revocation of this permit or other penalty
SEE "STANDARD CONDITIONS OF APPROVAL" SHEET
[] Town [] Village [] City [] County ~J State of: Municipality Number of Dwelling Location:
~ll~BIB~lOl~,J City Of Oshkosh 7 0 - 2 6 6
~IS UN!EORIVl ~ERMI~ ~ERIVlI~ iSSUED B~
~SS=E= SE~ Ne
~ Construction
Plan Review $75.00 _
HVAC Name JOHN Z. ARATE
Inspection
Electrical
Wis. Permit Seal $30.00
Plumbing
Date
1/14/04
Other [] Erosion
Total $105.00 · 306834 Cert. No. 70330
SBD-5823 (R. 07/92)
OSHKOSH
ON THE WATER
.lob Address 1370 JUDY LEE CT
Name RUSCH HOMES LLC
Address PO BOX 423
Subdivision 4th Add't Westleigh Farms
Building Permit Number 0106136
Number of Dwelling Units
Fee Required
PARKLAND DEDICATION FEE COLLECTION RECORD
Date 01/21/2004
OMRO WI 54963
Lot 214
1 Number of Structures
$200.00 Fee Paid
Owner's Signature
Inspector's Signature
Date
Date
OSHKOSH
ON THE WATER
Name RUSCH HOMES LLC
GRADE STAKE FORM
Address 1370 JUDY LEE CT
Lot 214 Block
Subdivision 4th Add't Westleigh Farms Zone
Street Number Lot Dimensions
Building Grade Elevation Stakes Set At Site 01/15/2004 Set By
Grade Stake Number 7092
Create Date 01/14/2004
Ward
D.W.G. EXISTING SW AT BOTH PL
Sidewalk Existing
Department of Public Works
I, the undersigned, owner or agent of the above described property agree to have the grade established before excavation
has commenced.
iF/EB 220U4
dRT
58'-6 1/2"
.s~~~
~~
S•
JUDY LEE COURT
7.5' SIDE SET BACK
...,
HOUSE
PLAN #
2-1879-203
25'-1 "
u~
M
N
PATIO
14X14
6'-1"
8' 2'
W.- 5'~~ 5'-0..
2 ( ~ z
GARAGE M J
DRIVEWAY AND I ~ Y
GRAVEL ACCESS DRIVE ' 2' m ~
24 MAX ®LOT LINE I ` n.
22' ~ a n a
S
N
N
r-
119.67'
~ ~p ~~~ i
ti PC,~f-
0
N W
~~ ~ ~ ~ I~
~ `. `_ N
2 N ~ ~S£Me `~` -.~
o~_9r Nr
~4. s~.
"v~
0
f IS 1liE COHtRM~R"S iESPOg9~61Llh' 7~0 EN9tJRE PROPER
ooMRa, ~r irs: a~ sir ~ aRrw~. sroacPwm soa. wusr eE 9~EOED MN1Ft RYE oR~ss oR oo~REo
aaROMa-Y OR om~ ~PP~cfim ~TMOO~tACN. ~unioRm. wmi ~ ~ EROSia+ ooMRO~. stwt eE PIJYCEO ~r oowN ROPE
~ON911LT ILIf.k. ;L1.12~5~ I.~.M.R 21.13. MD LACAL 81JN.OM1O flF i1E STO~~f'NF.
-rnR ~a ~ a~nars.
1370 JUDY LEE COURT ~ _~~w.~. ~~,~„~,,,,. SPA
CITY OF OSHKOSH
STANDARD CONDITIONS OF APPROVAL
Project Address_ ~ 37C~ ~ ~DY CE.F CT Permit #
Please read the following information and sign at the bottom to acknowledge that you have read
and agree to comply with these conditions.
All habitable rooms must be provided with 8% light and 3.5% ventilation. Bedrooms
located on the second floor or below ground level must be provided with egress windows
in addition to the light and ventilation requirements. Basement windows are also
required to have window well areas in accordance with ILHR 21.03.
2. Garage spaces shall be separated from the dwelling unit in accordance with ILHR 21.08.
The door and frame assembly between the dwelling unit and an attached garage shall be
labeled by an independent testing_a ency_ as having a minimum fire-resistive rating of 20
minutes. All drywall joints are required to be taped/sealed unless the joints are fitted so
that the gap is no more than a dimes thickness (1/20-inch) and backed by solid wood or
drywall with the joints staggered.
All penetrations in exterior walls must be sealed prior to the insulation inspection. This
includes holes in the top and bottom plates, gaps around heating ducts, and holes in the
return air spaces.
4. Smoke detectors are required on every floor and within 6' of all bedrooms. The smoke
detectors are required to be hardwired and interconnected.
5. Hydromassage tubs are required to have an access panel to motor. The access panel must
be accessible without removing the finish of the house.
6. All overframing must be designed by the truss manufacturer, according to standards set
by the truss plate institute, or structural calculations must be provided prior to the rough
building inspection.
7. Truss plans must be submitted and approved prior to framing the roof.
8. Truss plans including the truss layout must be provided on site at the rough building
inspection. In addition to the truss plans, microlam calculations must be provided on site
at the rough building inspection for all microlams with point loads on them.
9. Calculations must be provided for all cantilevered floors with point loads. Floor trusses
and TJI's must be designed for the cantilevered areas.
11. All storm sewer inlets must be protected with approved erosion control devices. Tracking
(i.e. sediment) must be removed from the street at the end of each workday. Repair any
siltation or erosion damage to adjoining surfaces and drainageways resulting from land
development or disturbing activities.
12. The building placard must be posted on site at all times. Once the rough framing is up
the placard must be posted on the patio door or on a kitchen window. If the placard is not
present at any inspection, stop work orders will be posted. Additional placards can be
obtained through our department if the cards are misplaced.
13. All mechanicals must be roughed in prior to requesting the rough building inspection. If
on the inspection the mechanicals are not roughed in, the inspection will fail and a $100
re-inspection fee will be charged.
14. Attached is a copy of the final inspection checklist. At the final inspection all items on
this list must be completed to avoid the $100 re-inspection fee per inspection.
15. When requesting final inspections please note that a minimum of 2 days notice is needed
from the time the inspection is ready. Furniture is only allowed to be placed in the center
of the garage floor and a minimum of a 3' pathway must be provided around the walls of
the garage. At the final inspection no furniture or personal belongings are allowed in the
house. Appliances such as the stove, refrigerator, washer, and dryer are not to be set in
place due to the electrical inspector needing to look at the power serving the appliances.
A 6' stepladder must be on site at the final inspection to provide access to the attic.
16. The building placard must remain on the patio door or on a kitchen window until
occupancy is approved. Occupancy is not allowed prior to the placard having all of the
final inspection approved stickers on the backside. If occupancy occurs prior to the
inspections being approved daily citations will be issued with no further notice being
given.
17. All site grading mu be done in accordance with the approved drainage plan on file in the
public works office, 3 floor.
~i~rraEure o~~ppCica ~ ~.
~a~e:
10. The property owner and applicant is responsible for compliance with ILHR 21.125
(Erosion Control). When installing access drives, a minimum of 2"-3" diameter stone is
required in addition to a minimum of 6" depth, 30'-50' length, and 14'-20' width. Erosion
control measures must be maintained until the lawn is established.